scholarly journals Galvanic vestibular stimulation: from basic concepts to clinical applications

2019 ◽  
Vol 121 (6) ◽  
pp. 2237-2255 ◽  
Author(s):  
Julia Dlugaiczyk ◽  
Kathrin D. Gensberger ◽  
Hans Straka

Galvanic vestibular stimulation (GVS) plays an important role in the quest to understand sensory signal processing in the vestibular system under normal and pathological conditions. It has become a highly relevant tool to probe neuronal computations and to assist in the differentiation and treatment of vestibular syndromes. Following its accidental discovery, GVS became a diagnostic tool that generates eye movements in the absence of head/body motion. With the possibility to record extracellular and intracellular spikes, GVS became an indispensable method to activate or block the discharge in vestibular nerve fibers by cathodal and anodal currents, respectively. Bernie Cohen, in his attempt to decipher vestibular signal processing, has used this method in a number of hallmark studies that have added to our present knowledge, such as the link between selective electrical stimulation of semicircular canal nerves and the generation of directionally corresponding eye movements. His achievements paved the way for other major milestones including the differential recruitment order of vestibular fibers for cathodal and anodal currents, pronounced discharge adaptation of irregularly firing afferents, potential activation of hair cells, and fiber type-specific activation of central circuits. Previous disputes about the structural substrate for GVS are resolved by integrating knowledge of ion channel-related response dynamics of afferents, fiber type-specific innervation patterns, and central convergence and integration of semicircular canal and otolith signals. On the basis of solid knowledge of the methodology, specific waveforms of GVS are currently used in clinical diagnosis and patient treatment, such as vestibular implants and noisy galvanic stimulation.

2002 ◽  
Vol 87 (4) ◽  
pp. 2064-2073 ◽  
Author(s):  
Erich Schneider ◽  
Stefan Glasauer ◽  
Marianne Dieterich

Galvanic vestibular stimulation (GVS) is reported to induce interindividually variable tonic ocular torsion (OT) and superimposed torsional nystagmus. It has been proposed that the tonic component results from the activation of otolith afferents. We tested our hypothesis that both the tonic and the phasic OT are mainly due to semicircular canal (SCC) stimulation by examining whether the OT patterns elicited by GVS can be reproduced by pure SCC stimulations. Using videooculography we measured the OT of six healthy subjects while two different stimuli with a duration of 20 s were applied: 1) transmastoidal GVS steps of 2 mA with the head in a pitched nose-down position and 2) angular head rotations around a combined roll-yaw axis parallel to the gravity vector with the head in the same position. The stimulation profile was individually scaled to match the nystagmus properties from GVS and consisted of a sustained velocity step of 4–12°/s on which a velocity ramp of 0.67–2°/s2 was superimposed. Since blinks were reported to induce transient torsional eye movements, the subjects were also asked to blink once 10 s after stimulus onset. Analysis of torsional eye movements under both conditions revealed no significant differences. Thus we conclude that both the tonic and the phasic OT responses to GVS can be reproduced by pure rotational stimulations and that the OT-related effects of GVS on SCC afferents are similar to natural stimulations at small amplitudes.


2011 ◽  
Vol 210 (3-4) ◽  
pp. 561-568 ◽  
Author(s):  
Brian L. Day ◽  
Elijane Ramsay ◽  
Miriam S. Welgampola ◽  
Richard C. Fitzpatrick

2021 ◽  
Author(s):  
Lorenz Assländer ◽  
Louis-Solal Giboin ◽  
Markus Gruber ◽  
Roman Schniepp ◽  
Max Wühr

Abstract Noisy galvanic vestibular stimulation (nGVS) at imperceptible levels has been shown to reduce body sway. This improvement was commonly attributed to the mechanism of stochastic resonance (SR). However, it has never been explicitly tested whether nGVS-induced effects on body sway consistently follow a SR-like bell-shaped performance curve with optimal improvements at intermediate noise intensities. To test this, body sway in 21 young healthy participants was measured during varying nGVS amplitudes while standing with eyes closed in 3 conditions (quiet stance, sway referencing, sinusoidal platform tilts). Presence of SR-compatible response dynamics in each trial was assessed (1) by a goodness-of-fit analysis using an established SR-curve model and (2) by ratings from 3 human experts. In accordance to theory, we found reductions of body sway at one nGVS amplitude in most trials (75-95%). However, only few trials exhibited SR-compatible bell-shaped performance curves with increasing noise amplitudes (10-33%). Instead, body sway measures rather fluctuated randomly across nGVS amplitudes. This implies that, at least in young healthy adults, nGVS effects on body sway are incompatible with SR. Thus, previously reported reductions of body sway at particular nGVS intensities more likely result from inherent variations of the performance metric or by other yet unknown mechanisms.


2002 ◽  
Vol 148 (3) ◽  
pp. 414-418 ◽  
Author(s):  
Alexandra Séverac Cauquil ◽  
Mary Faldon ◽  
Konstantin Popov ◽  
Brian L. Day ◽  
Adolfo M. Bronstein

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
L. Assländer ◽  
L. S. Giboin ◽  
M. Gruber ◽  
R. Schniepp ◽  
M. Wuehr

AbstractNoisy galvanic vestibular stimulation (nGVS) at imperceptible levels has been shown to reduce body sway. This reduction was commonly attributed to the mechanism of stochastic resonance (SR). However, it has never been explicitly tested whether nGVS-induced effects on body sway consistently follow a SR-like bell-shaped performance curve with maximal reductions in a particular range of noise intensities. To test this, body sway in 21 young healthy participants was measured during varying nGVS amplitudes while standing with eyes closed in 3 conditions (quiet stance, sway referencing, sinusoidal platform tilts). Presence of SR-like response dynamics in each trial was assessed (1) by a goodness-of-fit analysis using an established SR-curve model and (2) by ratings from 3 human experts. In accordance to theory, we found reductions of body sway at one nGVS amplitude in most trials (75–95%). However, only few trials exhibited SR-like bell-shaped performance curves with increasing noise amplitudes (10–33%). Instead, body sway measures rather fluctuated randomly across nGVS amplitudes. This implies that, at least in young healthy adults, nGVS effects on body sway are incompatible with SR. Thus, previously reported reductions of body sway at particular nGVS intensities more likely result from inherent variations of the performance metric or by other yet unknown mechanisms.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Po-Yin Chen ◽  
Ying-Chun Jheng ◽  
Chien-Chih Wang ◽  
Shih-En Huang ◽  
Ting-Hua Yang ◽  
...  

AbstractA single-blind study to investigate the effects of noisy galvanic vestibular stimulation (nGVS) in straight walking and 2 Hz head yaw walking for healthy and bilateral vestibular hypofunction (BVH) participants in light and dark conditions. The optimal stimulation intensity for each participant was determined by calculating standing stability on a force plate while randomly applying six graded nGVS intensities (0–1000 µA). The chest–pelvic (C/P) ratio and lateral deviation of the center of mass (COM) were measured by motion capture during straight and 2 Hz head yaw walking in light and dark conditions. Participants were blinded to nGVS served randomly and imperceivably. Ten BVH patients and 16 healthy participants completed all trials. In the light condition, the COM lateral deviation significantly decreased only in straight walking (p = 0.037) with nGVS for the BVH. In the dark condition, both healthy (p = 0.026) and BVH (p = 0.017) exhibited decreased lateral deviation during nGVS. The C/P ratio decreased significantly in BVH for 2 Hz head yaw walking with nGVS (p = 0.005) in light conditions. This study demonstrated that nGVS effectively reduced walking deviations, especially in visual deprived condition for the BVH. Applying nGVS with different head rotation frequencies and light exposure levels may accelerate the rehabilitation process for patients with BVH.Clinical Trial Registration This clinical trial was prospectively registered at www.clinicaltrials.gov with the Unique identifier: NCT03554941. Date of registration: (13/06/2018).


Sign in / Sign up

Export Citation Format

Share Document