scholarly journals A Study of the Critical Uncertainty Contributions in the Analysis of PCBs in Ambient Air

2008 ◽  
Vol 2008 ◽  
pp. 1-14 ◽  
Author(s):  
Andrew S. Brown ◽  
Richard J. C. Brown

The measurement of polychlorinated biphenyls (PCBs) in ambient air requires a complex, multistep sample preparation procedure prior to analysis by gas chromatography—mass spectrometry (GC-MS). Although routine analytical laboratories regularly carry out these measurements, they are often undertaken with little regard to the accurate calculation of measurement uncertainty, or appreciation of the sensitivity of the accuracy of the measurement to each step of the analysis. A measurement equation is developed for this analysis, and the contributory sources to the overall uncertainty when preparing calibration standards and other solutions by gravimetric and volumetric approaches are discussed and compared. For the example analysis presented, it is found that the uncertainty of the measurement is dominated by the repeatability of the GC-MS analysis and suggested that volumetric (as opposed to gravimetric) preparation of solutions does not adversely affect the overall uncertainty. The methodology presented in this work can also be applied to analogous methods for similar analytes, for example, those used to measure polycyclic aromatic hydrocarbons (PAHs), pesticides, dioxins, or furans in ambient air.

2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Iñaki Elorduy ◽  
Nieves Durana ◽  
José Antonio García ◽  
María Carmen Gómez ◽  
Lucio Alonso

Thermal desorption (TD) coupled with gas chromatography/mass spectrometry (TD-GC/MS) is a simple alternative that overcomes the main drawbacks of the solvent extraction-based method: long extraction times, high sample manipulation, and large amounts of solvent waste. This work describes the optimization of TD-GC/MS for the measurement of airborne polycyclic aromatic hydrocarbons (PAHs) in particulate phase. The performance of the method was tested by Standard Reference Material (SRM) 1649b urban dust and compared with the conventional method (Soxhlet extraction-GC/MS), showing a better recovery (mean of 97%), precision (mean of 12%), and accuracy (±25%) for the determination of 14 EPA PAHs. Furthermore, other 15 nonpriority PAHs were identified and quantified using their relative response factors (RRFs). Finally, the proposed method was successfully applied for the quantification of PAHs in real 8 h-samples (PM10), demonstrating its capability for determination of these compounds in short-term monitoring.


2004 ◽  
Vol 327 (1-3) ◽  
pp. 135-146 ◽  
Author(s):  
Guor-Cheng Fang ◽  
Cheng-Nan Chang ◽  
Yuh-Shen Wu ◽  
Peter Pi-Cheng Fu ◽  
I-Lin Yang ◽  
...  

Sign in / Sign up