scholarly journals Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Ricardo Salles Cauduro ◽  
Caroline do Amaral Ferraz ◽  
Maira Saad Ávila Morales ◽  
Patricia Novita Garcia ◽  
Yara Cristina Lopes ◽  
...  

Purpose.Application of anterior segment optical coherence (AS-OCT) in pediatric ophthalmology.Methods.Retrospective clinical study case series of 26 eyes of 19 pediatric patients throughout a 21-month period, presenting anterior segment pathologies, were submitted to AS-OCT examination (OCT Visante, 1310 nm, Zeiss), noncontact technique, no sedation requirement.Results.AS-OCT images were obtained from 19 patients (range: 2 months to 12 years). Clinical diagnosis of anterior segment abnormalities included cornea disease (n=7), congenital anterior segment conditions (n=10), ocular trauma (n=1), anterior segment surgeries (n=2), iridocorneal angle abnormalities (n=4), intermediate uveitis (n=2). The most common OCT findings were corneal hyperreflectivity and thickening (n=15), shallow anterior chamber with iris-lens diaphragm anterior displacement (n=4), atypical corneal curvature (n=4), corneal thinning (n=4), peripheral synechiae with angle closure (n=3), increased anterior chamber depth (n=2), and proximal portion of glaucoma drainage tube (n=2).Conclusion.In the present study, noncontact AS-OCT demonstrated to be a feasible technique to evaluate the anterior segment providing anatomic details and useful to clarify diagnosis in the pediatric population.

2019 ◽  
Author(s):  
Man Hu ◽  
Qian Zheng ◽  
Zhangliang Li ◽  
Pingjun Chang ◽  
Yun-e Zhao

Abstract Background To assess the changes of anterior chamber angle in patients with shallow anterior chamber and normal anterior chamber after phacoemulsification and intraocular lens implantation (IOL) using anterior segment swept-source optical coherence tomography (AS-SS-OCT). Methods This was a prospective case control study; 60 eyes of 60 patients who underwent cataract surgery. Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were classified into two groups, shallow anterior chamber group (30 eyes) and normal anterior chamber group (30 eyes). AS-SS-OCT was used to measure ACD and angle parameters angle opening distance (AOD), angle recess area (ARA), trabecular iris space area(TISA), and trabecular iris angle (TIA). Serial changes in each group were measured before and 3 months after phacoemulsification and IOL, and the differences between the two groups were compared. Results All angle parameters including ACD, AOD, ARA, TISA, and TIA in both groups at 3 months after cataract surgery were significantly different from the preoperative values (p<0.01). In addition, we found significant differences of all angle parameters between groups of shallow anterior chamber (SAC) and normal anterior chamber (NAC) (All P< 0.05). Besides, the TISA750 in superior quadrant and anterior chamber volume (ACV) were significantly smaller in the group of SAC than those in the group of NAC (P = 0.041 and 0.002, respectively). Conclusions The parameters of anterior chamber increased significantly in both two groups but not increase to the same extent 3 months after phacoemulsification. Iris thickening may also be one of the narrow angle factors,not just age-related lens thickening.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Poemen Pui-man Chan ◽  
Gilda Lai ◽  
Vivian Chiu ◽  
Anita Chong ◽  
Marco Yu ◽  
...  

Abstract This study compared the test–retest variabilities and measurement agreement of anterior chamber angle (ACA) dimensions measured by two anterior segment swept-source optical coherence tomography (SS-OCT)—the ANTERION (Heidelberg Engineering, Heidelberg, Germany) and CASIAII (Tomey, Nagoya, Japan). Thirty-eight subjects, 18 patients with primary angle closure and 20 healthy participants with open angles, were included. The mean age was 54.7 ± 15.8 years (range: 26–75 years). One eye of each subject was randomly selected for anterior segment imaging by ANTERION and CASIAII, using the same scan pattern (6 evenly spaced radial scans across the anterior segment for three times) in the same visit. The between- and within-instrument agreement and repeatability coefficients of angle open distance (AOD500), trabecular-iris space area (TISA500), lens vault (LV), scleral spur-scleral spur distance (SSD), anterior chamber depth (ACD), and pupil diameter (PD) were measured. The anterior and posterior boundaries of the cornea, iris, and lens were automatically segmented by the SS-OCT instruments; the scleral spur was manually located by a single masked observer. There were significant differences between ANTERION and CASIAII measurements; the SSD, PD, and ACD were smaller whereas AOD500 and TISA500 were greater in ANTERION compared with CASIAII (P < 0.001). Anterior segment measurements obtained from the two SS-OCT instruments showed strong associations (R2 ranged between 0.866 and 0.998) although the between-instrument agreement was poor; the spans of 95% limits of between-instrument agreement were ≥ 1.5-folds than the within-instrument agreement for either instrument. Whereas both SS-OCT instruments showed low test–retest measurement variabilities, the repeatability coefficients of AOD500, TISA500, ACD, and PD were slightly smaller for CASIAII than ANTERION (P ≤ 0.012).


2019 ◽  
Vol 104 (6) ◽  
pp. 795-799 ◽  
Author(s):  
Natalia Porporato ◽  
Mani Baskaran ◽  
Tin A Tun ◽  
Rehena Sultana ◽  
Marcus Tan ◽  
...  

Background/aimsAlthough being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy.MethodsCross-sectional study. A total of 2027 phakic subjects aged ≥50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of ≥35%, ≥50% and ≥75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT.ResultsTwo hundred and seventy-two (14.7%) resulted in overcall results (false positives) when ≥50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images.ConclusionsWe found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.


2021 ◽  
Author(s):  
Mohamed Salah El-Din Mahmoud ◽  
Nosiba Essam ◽  
Layla Mohamed Hammouda ◽  
Ahmed Shawkat Mohamed

Abstract Purpose: The study aims is to detect primary angle-closure glaucoma (PACG) suspects using both anterior segment optical coherence tomography (AS-OCT) and Scheimpflug imaging. Methods: A prospective cross-sectional observational study on forty PACG suspect patients with a range of ages from 20 to 70 years. Angle imaging by AS-OCT (Optovue Inc., Fairmont, CA) with study parameters in the superior, inferior, nasal, and temporal quadrants were anterior chamber angle (ACA), angle opening distance at 750 µm (AOD750), and trabecular-iris space area at 750 μm (TISA). Also, angle imaging using Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) with study parameters were the anterior chamber angle (ACA), anterior chamber depth (ACD) and, anterior chamber volume (ACV). The angle evaluation was done before and after the mydriatic test.Results: As regarding AS-OCT, after the mydriatic test, we noticed a decrease in all parameters measured, some decreased significantly while others did not. A significant decrease was noticed in ACA (TIA750) in all quadrants (P value<0.001in nasal, 0.001in superior &temporal, 0.003 in inferior) and in TISA750 in the nasal quadrant only (P-value 0.004). AOD750 and TISA750 in the remaining quadrants also decreased but not significantly as ACA. As regarding Pentacam, all parameters decreased after the mydriatic test. ACA (P-value <0.001) and ACD (P-value 0.004) showed significant statistical decrease but ACV showed statistically non-significant decrease (P-value 0.558).Conclusions: AS-OCT and Pentacam are reliable investigations for the detection of PACG suspects which needs more close follow-up for a possible increase in IOP.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2022 ◽  
Author(s):  
Mahmoud Ekram ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Asmaa Anwar Mohamed ◽  
Mohamed Farouk Sayed Othman Abdelkader

Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia University Hospital, Egypt from January 2019 to June 2021. All patients had complete ophthalmic examination and were followed up for 1 year. Pentacam was used for preoperative and postoperative estimation of anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV) and IPCL vault in the 1st, 3rd, and 12th months. Assessment of corneal endothelium was done using specular microscope preoperatively and after 12 months. Preoperative and postoperative refraction and visual acuity were measured. Results: There was a statistically significant decrease in ACD, ACA, and ACV. There was no significant difference between preoperative and postoperative mean intraocular pressure (IOP) by the 12th month (P=0.163). The mean preoperative endothelial cell count (ECD) was significantly reduced from 2929.3±248 cells/mm2 to 2737.9±303 cells/mm2 at the 12th month (P<0.001). with a statistically highly significant improvement of mean Log Mar uncorrected visual acuity (UCVA) from 1.48±0.19 preoperatively to 0.46±0.11 by the end of follow up (P<0.001) with insignificant difference between preoperative best corrected visual acuity (BCVA) and postoperative UCVA (P=0.209). In the 12th month, the mean vault was 240±540 μm. No sight threatening complications occurred.Conclusion: Although IPCL induced anatomical changes, it was safe and effective for correction of high myopia.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Qinghong Xie ◽  
Ping Ma ◽  
Jutima Patlidanon ◽  
Murtaza Saifee ◽  
Sean Yonamine ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Xiaoli Xiang ◽  
Yuan Chen ◽  
Jinyu Wang ◽  
Zhengru Huang ◽  
Zheng Gu

The management of acute angle closure combined with an extremely shallow anterior chamber and cataract remains complex. This study evaluated a technique of vitreous needle aspiration combined with phacoemulsification for the treatment of acute angle closure with continuous high intraocular pressure (IOP). We retrospectively reviewed the results of vitreous needle aspiration combined with phacoemulsification in 17 eyes (17 patients) with acute angle closure with continuous high IOP and coexisting visually significant cataracts between September 2018 and April 2020 at the glaucoma unit of the affiliated Changshu Hospital of Xuzhou Medical University. The main outcomes were the best corrected visual acuity (BCVA), IOP, anterior chamber depth (ACD), angle open distance 500 (AOD500), number of antiglaucoma medications, and surgery-associated complications. There were no complications during phacoemulsification and a foldable acrylic intraocular lens was implanted in the capsular bag in all 17 patients. For all patients, vitreous needle aspiration was successful at the first attempt. The BCVA improved from 2.02 ± 0.54 logMAR preoperatively to 0.73 ± 0.57 logMAR postoperatively at the final examination ( p < 0.001 ). The mean IOP was 54.47 ± 5.33 mmHg preoperatively and 15.59 ± 2.35 mmHg at the final examination ( p < 0.001 ) without any medication. The ACD was 1.70 ± 0.16 mm preoperatively and 3.35 ± 1.51 mm at the final examination ( p < 0.001 ). The AOD500 was 0.07 ± 0.02 mm preoperatively and 0.51 ± 0.04 mm at the final examination ( p < 0.001 ). Our vitreous needle aspiration technique can be performed safely in phacoemulsification for the management of acute angle closure with continuous high IOP.