scholarly journals Experiments on the Porch Swing Bearing of Michelson Interferometer for Low Resolution FTIR

2013 ◽  
Vol 2013 ◽  
pp. 1-9
Author(s):  
Tuomas Välikylä ◽  
Jyrki Kauppinen

Porch swing bearing for the linear motion of the mirror in Michelson interferometer for mid-infrared low resolution Fourier transform spectrometer was studied experimentally using the modulation depth of the collimated laser beam. The mirror tilting was measured to be lower than 5 μrad over 3 mm mirror travel using two different bearings assemblies. Additionally, the manufacturing tolerances of the bearing type were proved to be loose enough not to limit the interferometer application. These demonstrate that the porch swing without any adjustment mechanisms provides the sufficient motion linearity.

2014 ◽  
Vol 56 ◽  
Author(s):  
Shaomin Cai ◽  
Anu Dudhia

The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) instrument which operated on the Envisat satellite from 2002-2012 is a Fourier transform spectrometer for the measurement of high-resolution gaseous emission spectra at the Earth's limb. It operates in the near- to mid-infrared, where many of the main atmospheric trace gases have important emission features. The initial operational products were profiles of Temperature, H2O, O3, CH4, N2O, HNO3, and NO2, and this list was recently extended to include N2O5, ClONO2, CFC-11 and CFC-12. Here we present preliminary results of retrievals of the third set of species under consideration for inclusion in the operational processor: HCN, CF4, HCFC-22, COF2 and CCl4.


2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Rilong Liu

Based on the principle of the Michelson interferometer, the paper briefly describes the theoretical significance and calculates and deduces three expressions of the interference modulation depth. The influence of the surface shape error of plane mirror on modulation depth is analyzed, and the tolerance of error is also pointed out. Moreover, the dependence of modulation depth on the reflectance change of beam splitter interface is also analyzed, and the curve is given. It is concluded that this paper is of general significance for the Fourier transform spectrometer based on the principle of the Michelson two-beam interference.


2022 ◽  
Author(s):  
Thi Thuy Duong Dinh ◽  
xavier leroux ◽  
Natnicha Koompai ◽  
Daniele Melati ◽  
Miguel Montesinos Ballester ◽  
...  

2000 ◽  
Vol 78 (4) ◽  
pp. 317-325 ◽  
Author(s):  
M Mengel ◽  
B P Winnewisser ◽  
M Winnewisser

We report the results of our observations of liquid parahydrogen in the mid-infrared and of liquid parahydrogen and orthodeuterium in their first and second overtone regions using a Bruker IFS 120 HR Fourier transform spectrometer. We have determined intensity parameters for individual absorption features where possible and indicate analogies between the spectrum of the liquid and the corresponding spectrum of the solid phase of the hydrogens. PACS Nos.: 33.20Ea, 33.70Fd, 67.90+z


Author(s):  
Qiankun Liu ◽  
Joan Manel Ramirez ◽  
Vladyslav Vakarin ◽  
Xavier Le Roux ◽  
Carlos A. Alonso-Ramos ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document