scholarly journals The Study of Critical Heat Flux in Upflow Boiling Vertical Round Tube under High Pressure

2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
Wei Liu ◽  
Jianqiang Shan ◽  
Shinian Peng ◽  
Guangming Jiang ◽  
Yu Liu

The Critical Heat Flux (CHF) prediction under high pressure condition, even close to the vicinity of the critical pressure of water, is an important issue. Although there are many empirical CHF correlations, most of them have covered the pressure under 15MPa. In this study, based on the CHF experiment database of upflow boiling in vertical round tube from 15MPa to the vicinity of the critical pressure of water, the Katto, Bowring, Hall-Mudawar, Alekseev correlations, and Groeneveld LUT-2006 are comparatively studied. With an error analysis of the predicted CHF to the experiment database, the prediction capability and the applicability of these correlations are evaluated and the parametric trends of CHF varying with pressure from 15MPa to critical pressure are proposed. Simultaneously, according to the characteristics of Departure from Nucleate Boiling (DNB) type CHF under high pressure condition, the constitutive correlations of Weisman & Pei model are proposed. The prediction results of three entrainment and deposition correlations of Kataoka, Celata, and Hewitt corresponding to the Dry-Out (DO) type CHF are analyzed. Based on the two improved models above, a comprehensive CHF mechanistic model under high pressure condition combining the DNB and DO type CHF is established. The verification based on the experiment database of upflow boiling in vertical round tube and the parametric trends analysis of CHF varying with thermal-hydraulic and geometric parameters are carried out. Findings of this study have a positive effect on further development of CHF prediction method for universal CHF mechanism, especially under high pressure region.

Author(s):  
Muhamad Zuhairi Sulaiman ◽  
Masahiro Takamura ◽  
Kazuki Nakahashi ◽  
Tomio Okawa

Boiling heat transfer (BHT) and critical heat flux (CHF) performance were experimentally studied for saturated pool boiling of water-based nanofluids. In present experimental works, copper heaters of 20 mm diameter with titanium-oxide (TiO2) nanocoated surface were produced in pool boiling of nanofluid. Experiments were performed in both upward and downward facing nanofluid coated heater surface. TiO2 nanoparticle was used with concentration ranging from 0.004 until 0.4 kg/m3 and boiling time of tb = 1, 3, 10, 20, 40, and 60 mins. Distilled water was used to observed BHT and CHF performance of different nanofluids boiling time and concentration configurations. Nucleate boiling heat transfer observed to deteriorate in upward facing heater, however; in contrast effect of enhancement for downward. Maximum enhancements of CHF for upward- and downward-facing heater are 2.1 and 1.9 times, respectively. Reduction of mean contact angle demonstrate enhancement on the critical heat flux for both upward-facing and downward-facing heater configuration. However, nucleate boiling heat transfer shows inconsistency in similar concentration with sequence of boiling time. For both downward- and upward-facing nanocoated heater's BHT and CHF, the optimum configuration denotes by C = 400 kg/m3 with tb = 1 min which shows the best increment of boiling curve trend with lowest wall superheat ΔT = 25 K and critical heat flux enhancement of 2.02 times.


1999 ◽  
Author(s):  
Yasuo Koizumi ◽  
Hiroyasu Ohtake ◽  
Manabu Mochizuki

Abstract The effect of solid particle introduction on subcooled-forced flow boiling heat transfer and a critical heat flux was examined experimentally. In the experiment, glass beads of 0.6 mm diameter were mixed in subcooled water. Experiments were conducted in a range of the subcooling of 40 K, a velocity of 0.17–6.7 m/s, a volumetric particle ratio of 0–17%. When particles were introduced, the growth of a superheated liquid layer near a heat trasnsfer surface seemed to be suppressed and the onset of nucleate boiling was delayed. The particles promoted the condensation of bubbles on the heat transfer surface, which shifted the initiation of a net vapor generation to a high heat flux region. Boiling heat trasnfer was augmented by the particle introduction. The suppression of the growth of the superheated liquid layer and the promotion of bubble condensation and dissipation by the particles seemed to contribute that heat transfer augmentation. The wall superheat at the critical heat flux was elevated by the particle introduction and the critical heat flux itself was also enhanced. However, the degree of the critical heat flux improvement was not drastic.


Author(s):  
Bao H. Truong

Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed a CHF enhancement up to 68% and there seems to be a monotonic relationship between the nanoparticle concentration and the magnitude of enhancement. Alumina nanofluids had a CHF enhancement up to 56% but the peak occurred at the intermediate concentration. The boiling curves in nanofluid were found to shift to the left of that of water and correspond to higher nucleate boiling heat transfer coefficients in the two-phase flow regime. Scanning Electron Microscopy (SEM) images show a porous coating layer of nanoparticles on wires subjected to nanofluid CHF tests. These coating layers change the morphology of the heater’s surface, and are responsible for the CHF enhancement. The thickness of the coating was estimated using SEM and was found ranging from 3.0 to 6.0 micrometers for Alumina, and 3.0 to 15.0 micrometers for Silica.


Author(s):  
Fan Pu ◽  
Suizheng Qiu ◽  
Guanghui Su ◽  
Dounan Jia

The term annular flow is used to describe the configuration of vapor-liquid flow in which part of the liquid travels as a film on the wall and the rest is entrained as drops by the vapor core in the center of the channel. The objective of this paper is to develop a hydrodynamic model for vertical upward annular flow. A separated flow model is developed and the conservations of Mass, Momentum, Energy, entrainment rate correlation in wide range of conditions and interfacial frictional correlation are used to research the flow and heat transfer characteristic of annular flow. The liquid film thickness, liquid film mass flow rate, two-phase heat transfer coefficient pressure along axial position, local velocity profiles along radial position are predicted theoretically. The influence of the mass flux, heat flux on liquid film thickness, heat transfer coefficient etc. are investigated in detail. The critical heat flux are also predicted in vertical upward round tube according to the theory that the dryout in vertical annular flow emerges at the point where the film is depleted due to the integrating result of entrainment, deposition and evaporation. The influence of mass flux, inlet mass quality and tube diameter on critical heat flux is also predicted in this paper. Finally the predicted result of critical heat flux is compared with experimental data, and the theoretical CHF values are higher than that of experimental data, with error within 30%.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
S. R. Darr ◽  
J. W. Hartwig ◽  
J. Dong ◽  
H. Wang ◽  
A. K. Majumdar ◽  
...  

Recently, two-phase cryogenic flow boiling data in liquid nitrogen (LN2) and liquid hydrogen (LH2) were compared to the most popular two-phase correlations, as well as correlations used in two of the most widely used commercially available thermal/fluid design codes in Hartwig et al. (2016, “Assessment of Existing Two Phase Heat Transfer Coefficient and Critical Heat Flux on Cryogenic Flow Boiling Quenching Experiments,” Int. J. Heat Mass Transfer, 93, pp. 441–463). Results uncovered that the correlations performed poorly, with predictions significantly higher than the data. Disparity is primarily due to the fact that most two-phase correlations are based on room temperature fluids, and for the heating configuration, not the quenching configuration. The penalty for such poor predictive tools is higher margin, safety factor, and cost. Before control algorithms for cryogenic transfer systems can be implemented, it is first required to develop a set of low-error, fundamental two-phase heat transfer correlations that match available cryogenic data. This paper presents the background for developing a new set of quenching/chilldown correlations for cryogenic pipe flow on thin, shorter lines, including the results of an exhaustive literature review of 61 sources. New correlations are presented which are based on the consolidated database of 79,915 quenching points for a 1.27 cm diameter line, covering a wide range of inlet subcooling, mass flux, pressure, equilibrium quality, flow direction, and even gravity level. Functional forms are presented for LN2 and LH2 chilldown correlations, including film, transition, and nucleate boiling, critical heat flux, and the Leidenfrost point.


Sign in / Sign up

Export Citation Format

Share Document