scholarly journals Segmented Power Supply Preset Control Method of High-Speed Rail Contactless Traction Power Supply System considering Regenerative Braking Energy Recovery

2020 ◽  
Vol 2020 ◽  
pp. 1-15
Author(s):  
Ruoqiong Li ◽  
Junjie Wang ◽  
Xuan Zhao ◽  
Xin Li

For high-speed rail with high energy consumption, the recovery and utilization of regenerative braking energy is essential to improve the energy consumption of high-speed rail. As a technical link, the energy bidirectional feed inductively coupled power transfer (ICPT) system can realize the regenerative braking energy recovery of the contactless traction power supply system. Furthermore, considering that the braking energy of the high-speed rail is the largest when entering the station during the whole line operation, the braking section of the station is mainly considered. This paper proposes a preset control method for segmented power supply of the energy bidirectional feed ICPT system considering regenerative braking energy recovery. By establishing the steady-state mathematical model of the bidirectional ICPT system, the influence of the internal phase-shift angles φ1 and φ2 and the external phase-shift angle γ on the operating state of the system is analyzed. To realize system synchronization under the operation of EMUs, a train braking model is established through force analysis, and a power preset controller is designed to realize the synchronous control of the power flow of the bilateral system. According to the braking process of the train entering the station, the switching control method of the segment coil under the different conditions of the single train entering the station and the multitrain entering the station is proposed to ensure the reliability and flexibility of the train power supply. The simulation results of the 350 kW ICPT system simulation model show that the system can operate stably when the power transmission simulation is switched, and the transmission efficiency can reach 89%, which proves the feasibility of the control method. Energy-saving estimates show that a single train can recover about 200–300 kWh of electric energy during single braking. The comparison with the measured data verifies the accuracy of the modeling in this paper.

Energies ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 253
Author(s):  
Si Wu ◽  
Mingli Wu ◽  
Yi Wang

The existing problems of the traction power-supply system (i.e., the existence of the neutral section and the power quality problems) limit the development of railways, especially high-speed railways, which are developing rapidly worldwide. The existence of the neutral section leads to the speed loss and traction loss as well as mechanical failures, all of which threaten the fast and safe operation of the train and the system. Meanwhile, the power quality problems (e.g., the negative sequence current, the reactive power, and the harmonic) can bring a series of problems that cannot be ignored on the three-phase grid side. In response, many researchers have proposed co-phase power-supply schemes to solve these two problems simultaneously. Given that the auto-transformer (AT) power-supply mode has become the main power-supply mode for the high-speed railway traction power-supply system, it has a bright future following the rapid development of the high-speed railway. In addition, there is no co-phase power-supply scheme designed for AT power-supply mode in the existing schemes. Therefore, the main contribution of this paper is to propose a specifically designed power-supply mode more suitable for the AT, as well as to establish the control systems for the rectifier side and the inverter side. In addition, for the proposed scheme, the operation principle is analyzed, the mathematical model is built, and the control system is created, and its functionality is verified by simulation, and its advantages are compared and summarized finally. The result proves that it can meet functional requirements. At the same time, compared with the existing co-phase power-supply scheme, it saves an auto-transformer in terms of topology, reduces the current stress by 10.9% in terms of the current stress of the switching device, and reduces the power loss by 0.25% in terms of the entire system power loss, which will result in a larger amount of electricity being saved. All of this makes it a more suitable co-phase power-supply scheme for the AT power-supply mode.


Sign in / Sign up

Export Citation Format

Share Document