ScienceGate
Advanced Search
Author Search
Journal Finder
Blog
Sign in / Sign up
ScienceGate
Search
Author Search
Journal Finder
Blog
Sign in / Sign up
Monitoring of Transcutaneous Carbon Dioxide Tension in Neonates at Different Electrode Temperatures
Monitoring of Vital Parameters during Extracorporeal Circulation
◽
10.1159/000397287
◽
2015
◽
pp. 215-220
Author(s):
Peter Vesterager
◽
Richard J. Martin
Keyword(s):
Carbon Dioxide
◽
Carbon Dioxide Tension
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Related Documents
Cited By
References
Controlling of High Frequency Jet Ventilation (HFJV) by Measurement of the Transcutaneous Carbon Dioxide Tension (tcPCO 2 ) During Rigid Bronchoscop
CHEST Journal
◽
10.1378/chest.124.4_meetingabstracts.125s
◽
2003
◽
Vol 124
(4)
◽
pp. 125S
Author(s):
Clemens Männle
◽
Felix J. Herth
◽
Heinrich D. Becker
◽
Klaus Wiedemann
Keyword(s):
Carbon Dioxide
◽
High Frequency
◽
Carbon Dioxide Tension
◽
Jet Ventilation
◽
High Frequency Jet Ventilation
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
A.62 Transcutaneous carbon dioxide tension vs end-tidal carbon dioxide partial pressure during laparoscopic surgery
British Journal of Anaesthesia
◽
10.1016/s0007-0912(18)30917-6
◽
1996
◽
Vol 76
◽
pp. 19
Author(s):
M. Fleyfel
◽
C. Telion
◽
S. Vangreveninge
◽
P. Scherpereel
Keyword(s):
Carbon Dioxide
◽
Laparoscopic Surgery
◽
Partial Pressure
◽
Carbon Dioxide Tension
◽
Carbon Dioxide Partial Pressure
◽
Transcutaneous Carbon Dioxide
◽
End Tidal Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
◽
End Tidal
Download Full-text
RELIABILITY AND SAFETY OF TRANSCUTANEOUS CARBON DIOXIDE TENSION (tcPCO2): MONITORING AT 42°C SENSOR TEMPERATURE DURING 24 HRS WITHOUT REPLACEMENT
Pediatric Research
◽
10.1203/00006450-198510000-00094
◽
1985
◽
Vol 19
(10)
◽
pp. 1083-1083
Author(s):
H U Bucher
◽
S Fanconi
◽
G Duc
Keyword(s):
Carbon Dioxide
◽
Carbon Dioxide Tension
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
◽
Sensor Temperature
Download Full-text
Normal Range of Fetal Transcutaneous Carbon Dioxide Tension During Labor
Obstetric Anesthesia Digest
◽
10.1097/00132582-198901000-00016
◽
1989
◽
Vol 8
(4)
◽
pp. 172
Author(s):
C. Nickelsen
◽
T. Weber
◽
Ira H. Gewolb
Keyword(s):
Carbon Dioxide
◽
Carbon Dioxide Tension
◽
Normal Range
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension
Scandinavian Journal of Clinical and Laboratory Investigation
◽
10.3109/00365513.2011.590601
◽
2011
◽
Vol 71
(7)
◽
pp. 548-552
◽
Cited By ~ 10
Author(s):
Line C. Sørensen
◽
Lene Brage-Andersen
◽
Gorm Greisen
Keyword(s):
Carbon Dioxide
◽
Carbon Dioxide Tension
◽
Electrode Temperature
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Application of Transcutaneous Carbon Dioxide Tension Monitoring with Low Electrode Temperatures in Premature Infants in the Early Postnatal Period
American Journal of Perinatology
◽
10.1055/s-0033-1352485
◽
2013
◽
Vol 31
(05)
◽
pp. 435-440
Author(s):
Masahiro Nishihara
◽
Yukari Oshima
◽
Shinya Hirano
◽
Hiroyuki Kitajima
◽
Katsuya Hirata
Keyword(s):
Carbon Dioxide
◽
Premature Infants
◽
Carbon Dioxide Tension
◽
Postnatal Period
◽
Early Postnatal Period
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Transcutaneous carbon dioxide tension for the evaluation of limb ischemia
Surgery Today
◽
10.1007/s00595-007-3773-4
◽
2009
◽
Vol 39
(1)
◽
pp. 9-13
Author(s):
Ikuo Sugimoto
◽
Takashi Ohta
◽
Hiroyuki Ishibashi
◽
Hirohide Iwata
◽
Jun Kawanishi
◽
...
Keyword(s):
Carbon Dioxide
◽
Limb Ischemia
◽
Carbon Dioxide Tension
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Optimal temperature for the measurement of transcutaneous carbon dioxide tension in the neonate
The Journal of Pediatrics
◽
10.1016/s0022-3476(80)80148-x
◽
1980
◽
Vol 97
(1)
◽
pp. 114-117
◽
Cited By ~ 31
Author(s):
Nancy Herrell
◽
Richard J. Martin
◽
Mark Pultusker
◽
Marvin Lough
◽
Avroy Fanaroff
Keyword(s):
Carbon Dioxide
◽
Carbon Dioxide Tension
◽
Optimal Temperature
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Propofol Safety in Bronchoscopy: Prospective Randomized Trial Using Transcutaneous Carbon Dioxide Tension Monitoring
Respiration
◽
10.1159/000331506
◽
2011
◽
Vol 82
(6)
◽
pp. 515-521
◽
Cited By ~ 20
Author(s):
Uri Carmi
◽
Mordechai R. Kramer
◽
Dmitry Zemtzov
◽
Dror Rosengarten
◽
Oren Fruchter
Keyword(s):
Carbon Dioxide
◽
Randomized Trial
◽
Carbon Dioxide Tension
◽
Prospective Randomized Trial
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Accuracy of Transcutaneous Carbon Dioxide Tension Measurements during Cardiopulmonary Exercise Testing
Respiration
◽
10.1159/000187631
◽
2009
◽
Vol 78
(2)
◽
pp. 147-153
◽
Cited By ~ 15
Author(s):
Gerben Stege
◽
Frank J.J. van den Elshout
◽
Yvonne F. Heijdra
◽
Marjo J.T. van de Ven
◽
P.N. Richard Dekhuijzen
◽
...
Keyword(s):
Carbon Dioxide
◽
Exercise Testing
◽
Cardiopulmonary Exercise Testing
◽
Carbon Dioxide Tension
◽
Cardiopulmonary Exercise
◽
Transcutaneous Carbon Dioxide
◽
Transcutaneous Carbon Dioxide Tension
Download Full-text
Sign in / Sign up
Close
Export Citation Format
Close
Share Document
Close