scholarly journals Atrial Septal Defect Mimicking Right Atrial Myxoma

2020 ◽  
Vol 13 (3) ◽  
Author(s):  
Heleen B. van der Zwaan ◽  
Sharon W. Kirschbaum ◽  
Sanne M. Snelder ◽  
Jan von der Thüsen ◽  
Bas M. van Dalen
1982 ◽  
Vol 8 (3) ◽  
pp. 267-272 ◽  
Author(s):  
Ponnuswamy Natarajan ◽  
Raghavendra R. Vijayanagar ◽  
Paul F. Eckstein ◽  
Diego A. Bognolo ◽  
John C. Toole

Surgery Today ◽  
1994 ◽  
Vol 24 (2) ◽  
pp. 176-178 ◽  
Author(s):  
Ichirou Suzuki ◽  
Shirosaku Koide ◽  
Shigetoh Odagiri ◽  
Akira Shohtsu

2008 ◽  
Vol 10 (2) ◽  
pp. 362-364 ◽  
Author(s):  
Mohammed A.R. Chamsi-Pasha ◽  
Ashraf M. Anwar ◽  
Youssef F.M. Nosir ◽  
Walid Abukhudair ◽  
Abdullah Ashmeg ◽  
...  

2005 ◽  
Vol 8 (2) ◽  
pp. 96 ◽  
Author(s):  
Osman Tansel Dar�in ◽  
Alper Sami Kunt ◽  
Mehmet Halit Andac

Background: Although various synthetic materials and pericardium have been used for atrial septal defect (ASD) closure, investigators are continuing to search for an ideal material for this procedure. We report and evaluate a case in which autologous right atrial wall tissue was used for ASD closure. Case: In this case, we closed a secundum ASD of a 22-year-old woman who also had right atrial enlargement due to the defect. After establishing standard bicaval cannulation and total cardiopulmonary bypass, we opened the right atrium with an oblique incision in a superior position to a standard incision. After examining the secundum ASD, we created a flap on the inferior rim of the atrial wall. A stay suture was stitched between the tip of the flap and the superior rim of the defect, and suturing was continued in a clockwise direction thereafter. Considering the size and shape of the defect, we incised the inferior attachment of the flap, and suturing was completed. Remnants of the flap on the inferior rim were resected, and the right atrium was closed in a similar fashion. Results: During an echocardiographic examination, neither a residual shunt nor perigraft thrombosis was seen on the interatrial septum. The patient was discharged with complete recovery. Conclusion: Autologous right atrial patch is an ideal material for ASD closure, especially in patients having a large right atrium. A complete coaptation was achieved because of the muscular nature of the right atrial tissue and its thickness, which is a closer match to the atrial septum than other materials.


2015 ◽  
Vol 17 (6) ◽  
pp. 282
Author(s):  
Suguru Ohira ◽  
Kiyoshi Doi ◽  
Takeshi Nakamura ◽  
Hitoshi Yaku

Sinus venosus atrial septal defect (ASD) is usually associated with partial anomalous pulmonary venous return (PAPVR) of the right pulmonary veins to the superior vena cava (SVC), or to the SVC-right atrial junction. Standard procedure for repair of this defect is a patch roofing of the sinus venosus ASD and rerouting of pulmonary veins. However, the presence of SVC stenosis is a complication of this technique, and SVC augmentation is necessary in some cases. We present a simple technique for concomitant closure of sinus venosus ASD associated with PAPVR and augmentation of the SVC with a single autologous pericardial patch.


Author(s):  
Bharath V. ◽  
Milind Padmakar Hote

AbstractA 57-year-old female presented to emergency with features of right heart failure. On evaluation, she was found to have a large mass occupying right atrium (RA) completely and protruding into right ventricle through tricuspid valve. Intraoperatively, mass was seen arising from RA free wall with stony hard consistency. Histopathology revealed it to be myxoma. We present this case for the rare presentation of myxoma masquerading as malignancy.


2020 ◽  
pp. 1-2
Author(s):  
Uma Devi Karuru ◽  
Saurabh Kumar Gupta

Abstract It is not uncommon to have prolapse of the atrial septal occluder device despite accurate measurement of atrial septal defect and an appropriately chosen device. This is particularly a problem in cases with large atrial septal defect with absent aortic rim. Various techniques have been described for successful implantation of atrial septal occluder in such a scenario. The essence of all these techniques is to prevent prolapse of the left atrial disc through the defect while the right atrial disc is being deployed. In this brief report, we illustrate the use of cobra head deformity of the device to successfully deploy the device across the atrial septum.


Sign in / Sign up

Export Citation Format

Share Document