scholarly journals Establishing the 99th percentile for high sensitivity cardiac troponin I in healthy blood donors from Southern Italy

2019 ◽  
Vol 29 (2) ◽  
pp. 402-406 ◽  
Author(s):  
Luisa Agnello ◽  
Giulia Bivona ◽  
Marcello Ciaccio ◽  
Bruna Lo Sasso ◽  
Maddalena Muratore ◽  
...  

Introduction: The knowledge of high sensitivity cardiac troponin I (hsTnI) distribution in a reference population is mandatory for its introduction in clinical practice. The aim of this study was to define the Upper Reference Limit (URL) of hsTnI measured by Single Molecule Counting technology (SMC) in an accurately selected reference population. Materials and methods: In the study 1140 blood donors were included and selected on the basis of medical history and biomarkers. High sensitivity cardiac troponin I was measured by SMC technology (Clarity, Singulex, Alamed, USA). The 99th percentile was calculated by the non-parametric method according to the Clinical and Laboratory Standard Institute - CLSI C28-A3. Results: The median age was 41 years (IQR: 28 - 50) and 69% were males. The overall 99th percentile was 5 ng/L (90% CI: 4.2 - 5.6). When considering sex-related differences, we found slight differences between the 99th percentile in males and females. Moreover, the 99th percentile trended with age, especially in females. Conclusions: We defined the 99th percentile of hs-cTnI measured by SMC technology in a highly selected healthy population, with only minor differences between males and females. Our findings provide the basic criteria for the reliable interpretation of hsTnI concentrations measured by the SMC technology in clinical settings.

2009 ◽  
Vol 55 (1) ◽  
pp. 196-198 ◽  
Author(s):  
Alan H B Wu ◽  
Sara J Agee ◽  
Quynh Anh Lu ◽  
John Todd ◽  
Allan S Jaffe

Author(s):  
Peter A. Kavsak ◽  
Tara Edge ◽  
Chantele Roy ◽  
Paul Malinowski ◽  
Karen Bamford ◽  
...  

AbstractObjectivesTo analytically evaluate Ortho Clinical Diagnostics VITROS high-sensitivity cardiac troponin I (hs-cTnI) assay in specific matrices with comparison to other hs-cTn assays.MethodsThe limit of detection (LoD), imprecision, interference and stability testing for both serum and lithium heparin (Li-Hep) plasma for the VITROS hs-cTnI assay was determined. We performed Passing-Bablok regression analyses between sample types for the VITROS hs-cTnI assay and compared them to the Abbott ARCHITECT, Beckman Access and the Siemens ADVIA Centaur hs-cTnI assays. We also performed Receiver-operating characteristic curve analyses with the area under the curve (AUC) determined in an emergency department (ED)-study population (n=131) for myocardial infarction (MI).ResultsThe VITROS hs-cTnI LoD was 0.73 ng/L (serum) and 1.4 ng/L (Li-Hep). Stability up to five freeze-thaws was observed for the Ortho hs-cTnI assay, with the analyte stability at room temperature in serum superior to Li-Hep with gross hemolysis also affecting Li-Hep plasma hs-cTnI results. Comparison of Li-Hep to serum concentrations (n=202), yielded proportionally lower concentrations in plasma with the VITROS hs-cTnI assay (slope=0.85; 95% confidence interval [CI]:0.83–0.88). In serum, the VITROS hs-cTnI concentrations were proportionally lower compared to other hs-cTnI assays, with similar slopes observed between assays in samples frozen <−70 °C for 17 years (ED-study) or in 2020. In the ED-study, the VITROS hs-cTnI assay had an AUC of 0.974 (95%CI:0.929–0.994) for MI, similar to the AUCs of other hs-cTn assays.ConclusionsLack of standardization of hs-cTnI assays across manufacturers is evident. The VITROS hs-cTnI assay yields lower concentrations compared to other hs-cTnI assays. Important differences exist between Li-Hep plasma and serum, with evidence of stability and excellent clinical performance comparable to other hs-cTn assays.


Author(s):  
Peter A. Kavsak ◽  
Shawn Mondoux ◽  
Andrew Worster ◽  
Janet Martin ◽  
Vikas Tandon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document