Mechanisms Of Decline In Serum Bactericidal Activity For Nontypeable Haemophilus Influenzae (NTHI) In COPD Patients Chronically Colonized With NTHI

Author(s):  
Himanshu Desai ◽  
Catherine Wrona ◽  
Timothy F. Murphy ◽  
Sanjay Sethi
2010 ◽  
Vol 18 (2) ◽  
pp. 243-247 ◽  
Author(s):  
Nadine G. Rouphael ◽  
Sarah Satola ◽  
Monica M. Farley ◽  
Karen Rudolph ◽  
Daniel S. Schmidt ◽  
...  

ABSTRACTHaemophilus influenzaetype a (Hia) is an important pathogen for some American Indian, Alaskan native, and Northern Canada aboriginal populations. Assays to measure serum bactericidal activity (SBA) to Hia have not been developed or validated. Here, we describe two methods for the measurement of SBA: SBA with a viability endpoint (CFU counts) and SBA with a fluorometric endpoint using alamarBlue as the metabolic indicator. Both SBA assays measure Hia-specific functional antibody and correlate with anti-Hia IgG enzyme-linked immunosorbent assay (ELISA) concentration of naturally acquired antibodies.


2013 ◽  
Vol 19 (3) ◽  
pp. 441-446 ◽  
Author(s):  
Masahiro Takahata ◽  
Yoko Sugiura ◽  
Yuko Shinmura ◽  
Yoshiko Fukuda ◽  
Nobuhiko Nomura

Microbiology ◽  
1984 ◽  
Vol 130 (3) ◽  
pp. 665-672 ◽  
Author(s):  
T. L. STULL ◽  
R. F. JACOBS ◽  
J. E. HAAS ◽  
M. C. ROBERTS ◽  
C. B. WILSON ◽  
...  

2004 ◽  
Vol 11 (1) ◽  
pp. 89-93 ◽  
Author(s):  
Sandra Romero-Steiner ◽  
Willie Spear ◽  
Nekeidra Brown ◽  
Patricia Holder ◽  
Thomas Hennessy ◽  
...  

ABSTRACT We evaluated alamarBlue as a metabolic indicator in a standardized assay for the measurement of serum bactericidal activity (SBA) to Haemophilus influenzae type b (Hib) using sera containing natural and vaccine-induced anticapsular (polyribosylribitol phosphate) antibodies. SBA assays with a colorimetric and a fluorometric end point in the presence of alamarBlue were developed and compared to a standard SBA assay, where colony counts are performed to determine the titer (12). A colorimetric end point required a spectrophotometer, whereas a fluorometric end point required a fluorometer. Prevaccination sera (n = 27) and postvaccination sera (n = 13) were tested by all three methodologies, and the SBA titers obtained in the presence of alamarBlue were compared to those from the standard method. Both the colorimetric and the fluorometric SBA titers were significantly correlated (r = 0.87 and r = 0.95, respectively) with those of the standard assay (≥50% killing as the SBA titer end point), and titers were not significantly different when compared to those of the standard assay (P > 0.68). However, the fluorometric end point had superior performance and ease of titer determination compared to the colorimetric end point (95 versus 87% of SBA titers were within 2 dilutions of the standard titer). Hib SBA assays with alamarBlue are reproducible, faster (same-day assay), and easier to perform than the standardized assay, which requires manual or automated colony counts. These semiautomated methodologies result in increased sample throughput and collection of data in digital formats that can be exported to data analysis programs for determination of SBA titers.


Sign in / Sign up

Export Citation Format

Share Document