scholarly journals Flexible contextual modulation of naturalistic texture perception in peripheral vision

2021 ◽  
Vol 21 (1) ◽  
pp. 1
Author(s):  
Daniel Herrera-Esposito ◽  
Ruben Coen-Cagli ◽  
Leonel Gomez-Sena
2020 ◽  
Author(s):  
Daniel Herrera-Esposito ◽  
Ruben Coen-Cagli ◽  
Leonel Gomez-Sena

AbstractPeripheral vision comprises most of our visual field, and is essential in guiding visual behavior. Its characteristic capabilities and limitations, which distinguish it from foveal vision, have been explained by the most influential theory of peripheral vision as the product of representing the visual input using summary-statistics. Despite its success, this account may provide a limited understanding of peripheral vision, because it neglects processes of perceptual grouping and segmentation. To test this hypothesis, we studied how contextual modulation, namely the modulation of the perception of a stimulus by its surrounds, interacts with segmentation in human peripheral vision. We used naturalistic textures, which are directly related to summary-statistics representations. We show that segmentation cues affect contextual modulation, and that this is not captured by our implementation of the summary-statistics model. We then characterize the effects of different texture statistics on contextual modulation, providing guidance for extending the model, as well as for probing neural mechanisms of peripheral vision.


Author(s):  
Thomas E. Moriarty ◽  
Andrew M. Junker ◽  
Don R. Price

2013 ◽  
Vol 133 (1) ◽  
pp. 2-7 ◽  
Author(s):  
Kensuke Tobitani ◽  
Kunihito Kato ◽  
Kazuhiko Yamamoto
Keyword(s):  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Fazilet Zeynep Yildirim ◽  
Daniel R. Coates ◽  
Bilge Sayim

AbstractThe perception of a target depends on other stimuli surrounding it in time and space. This contextual modulation is ubiquitous in visual perception, and is usually quantified by measuring performance on sets of highly similar stimuli. Implicit or explicit comparisons among the stimuli may, however, inadvertently bias responses and conceal strong variability of target appearance. Here, we investigated the influence of contextual stimuli on the perception of a repeating pattern (a line triplet), presented in the visual periphery. In the neutral condition, the triplet was presented a single time to capture its minimally biased perception. In the similar and dissimilar conditions, it was presented within stimulus sets composed of lines similar to the triplet, and distinct shapes, respectively. The majority of observers reported perceiving a line pair in the neutral and dissimilar conditions, revealing ‘redundancy masking’, the reduction of the perceived number of repeating items. In the similar condition, by contrast, the number of lines was overestimated. Our results show that the similar context did not reveal redundancy masking which was only observed in the neutral and dissimilar context. We suggest that the influence of contextual stimuli has inadvertently concealed this crucial aspect of peripheral appearance.


2020 ◽  
pp. bjophthalmol-2020-317034
Author(s):  
Meghal Gagrani ◽  
Jideofor Ndulue ◽  
David Anderson ◽  
Sachin Kedar ◽  
Vikas Gulati ◽  
...  

PurposeGlaucoma patients with peripheral vision loss have in the past subjectively described their field loss as ‘blurred’ or ‘no vision compromise’. We developed an iPad app for patients to self-characterise perception within areas of glaucomatous visual field loss.MethodsTwelve glaucoma patients with visual acuity ≥20/40 in each eye, stable and reliable Humphrey Visual Field (HVF) over 2 years were enrolled. An iPad app (held at 33 cm) allowed subjects to modify ‘blur’ or ‘dimness’ to match their perception of a 2×2 m wall-mounted poster at 1 m distance. Subjects fixated at the centre of the poster (spanning 45° of field from centre). The output was degree of blur/dim: normal, mild and severe noted on the iPad image at the 54 retinal loci tested by the HVF 24-2 and was compared to threshold sensitivity values at these loci. Monocular (Right eye (OD), left eye (OS)) HVF responses were used to calculate an integrated binocular (OU) visual field index (VFI). All three data sets were analysed separately.Results36 HVF and iPad responses from 12 subjects (mean age 71±8.2y) were analysed. The mean VFI was 77% OD, 76% OS, 83% OU. The most common iPad response reported was normal followed by blur. No subject reported dim response. The mean HVF sensitivity threshold was significantly associated with the iPad response at the corresponding retinal loci (For OD, OS and OU, respectively (dB): normal: 23, 25, 27; mild blur: 18, 16, 22; severe blur: 9, 9, 11). On receiver operative characteristic (ROC) curve analysis, the HVF retinal sensitivity cut-off at which subjects reported blur was 23.4 OD, 23 OS and 23.3 OU (dB).ConclusionsGlaucoma subjects self-pictorialised their field defects as blur; never dim or black. Our innovation allows translation of HVF data to quantitatively characterise visual perception in patients with glaucomatous field defects.


Author(s):  
Jan Kremláček ◽  
Jana Nekolová ◽  
Markéta Středová ◽  
Jana Langrová ◽  
Jana Szanyi ◽  
...  

Abstract Background For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a “Scharioth macula lens” (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens). Methods Fourteen patients (5 M, 9 F, 63–87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity. Results Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs. Conclusion SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.


2011 ◽  
Vol 49 (7) ◽  
pp. 2013-2021 ◽  
Author(s):  
Simon Rigoulot ◽  
Fabien D’Hondt ◽  
Sabine Defoort-Dhellemmes ◽  
Pascal Despretz ◽  
Jacques Honoré ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document