scholarly journals Broadband and High-Resolution Static Fourier Transform Spectrometer with Bandpass Sampling

2018 ◽  
Vol 72 (7) ◽  
pp. 1116-1121 ◽  
Author(s):  
Meriç Özcan ◽  
Behzad Sardari

In this study, experimental demonstration of a static Fourier transform spectrometer (static-FTS), based on division of the spectrum into multiple narrowband signals, is presented. The bandpass sampling technique used in this novel spectrometer solves the Nyquist sampling rate limitations and enables recording of wideband spectrum in high resolution. The proposed spectrometer not only has the potential of operating in a wide spectral range, but also has a resolution potential better than 2 cm−1.

1978 ◽  
Vol 17 (11) ◽  
pp. 1716 ◽  
Author(s):  
A. A. Balashov ◽  
V. S. Bukreev ◽  
N. G. Kultepin ◽  
I. N. Nesteruk ◽  
E. B. Perminov ◽  
...  

2014 ◽  
Vol 56 ◽  
Author(s):  
Shaomin Cai ◽  
Anu Dudhia

The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) instrument which operated on the Envisat satellite from 2002-2012 is a Fourier transform spectrometer for the measurement of high-resolution gaseous emission spectra at the Earth's limb. It operates in the near- to mid-infrared, where many of the main atmospheric trace gases have important emission features. The initial operational products were profiles of Temperature, H2O, O3, CH4, N2O, HNO3, and NO2, and this list was recently extended to include N2O5, ClONO2, CFC-11 and CFC-12. Here we present preliminary results of retrievals of the third set of species under consideration for inclusion in the operational processor: HCN, CF4, HCFC-22, COF2 and CCl4.


1989 ◽  
Vol 67 (11) ◽  
pp. 1027-1035 ◽  
Author(s):  
A. R. W. McKellar

The spectrum of CH4 obtained in CH4 plus N2 mixtures at a temperature of 77 K has been recorded with a spectral resolution of 0.14 cm−1 in the region 3800 to 9100 cm−1. The experiments were performed with long paths (66 or 88 m) in a cooled absorption cell using a Fourier-transform spectrometer. Data are presented here at low and medium resolution, and examples of some spectral regions are also shown at high resolution. The complete results are available from the author in an Appendix. Comparisons are made with previous model calculations of CH4 absorption, and with the observed spectrum of Neptune's satellite, Triton. The results should be useful for the interpretation of the spectra of Triton, Titan, and Pluto. They will also be of value for testing model calculations of low-temperature CH4 absorption, which, thus verified, can be used with greater confidence to analyze observations of Jupiter, Saturn Uranus, and Neptune.


2021 ◽  
Author(s):  
Erik Kretschmer ◽  
Felix Friedl-Vallon ◽  
Thomas Gulde ◽  
Michael Höpfner ◽  
Sören Johansson ◽  
...  

<p>The GLORIA-B (Gimballed Limb Observer for Radiance Imaging of the Atmosphere - Balloon) instrument is an adaptation of the very successful GLORIA-AB imaging Fourier transform spectrometer (iFTS) flown on the research aircrafts HALO and M55 Geophysica. The high spectral resolution in the LWIR (Long Wave Infrared) allows for the retrieval of temperature and of a broad range of atmospheric trace gases, with the goal to retrieve O<sub>3</sub>, H<sub>2</sub>O, HNO<sub>3</sub>, C<sub>2</sub>H<sub>6</sub>, C<sub>2</sub>H<sub>2</sub>, HCOOH, CCl<sub>4</sub>, PAN, ClONO<sub>2</sub>, CFC-11, CFC-12, SF<sub>6</sub>, OCS, NH<sub>3</sub>, HCN, BrONO<sub>2</sub>, HO<sub>2</sub>NO<sub>2</sub>, N<sub>2</sub>O<sub>5</sub> and NO<sub>2</sub>. The radiometric sensitivity of the Balloon instrument is further increased in comparison with the GLORIA-AB instrument by having two detector channels on the same focal plane array, while keeping the same concept of a cooled optical system. This system improvement was achieved with minimal adaptation of the existing optical system.</p><p>The high spatial and temporal resolution of the instrument is ensured by the imaging capability of the Fourier transform spectrometer while stabilizing the line-of-sight in elevation with the instrument and in azimuth with the balloon gondola. In a single measurement lasting 13 seconds, the atmosphere can be sounded from mid-troposphere up to flight altitude, typically 30 km, with a vertical resolution always better than 1 km for most retrieved species; a spatial resolution up to 0.3 km can be achieved in favourable conditions. Temperature retrieval precision between 0.1 and 0.2 K is expected. A spectral sampling up to 0.0625 cm<sup>-1</sup> can be achieved.</p><p>The first flight of GLORIA-B shall take place during the late-summer polar jet turn-around at Kiruna/ESRANGE. This flight is organised in the frame of the HEMERA project and was scheduled for summer 2020, but was ultimately postponed to summer 2021. Beyond qualification of the first balloon-borne iFTS, the scientific goals of the flight are, among others, the quantification of the stratospheric bromine budget and its diurnal evolution by measuring vertical profiles of BrONO<sub>2 </sub>in combination with BrO observations by the DOAS instrument of University Heidelberg on the same platform.</p>


1987 ◽  
Vol 26 (18) ◽  
pp. 3818 ◽  
Author(s):  
Bruno Carli ◽  
Massimo Carlotti ◽  
Francesco Mencaraglia ◽  
Enzo Rossi

The Analyst ◽  
2018 ◽  
Vol 143 (19) ◽  
pp. 4699-4706 ◽  
Author(s):  
Kaiyuan Zheng ◽  
Chuantao Zheng ◽  
Zidi Liu ◽  
Qixin He ◽  
Qiaoling Du ◽  
...  

The majority of broadband cavity-enhanced systems are used to detect trace gas species in the visible spectral range.


Sign in / Sign up

Export Citation Format

Share Document