trace gas
Recently Published Documents


TOTAL DOCUMENTS

2410
(FIVE YEARS 454)

H-INDEX

95
(FIVE YEARS 8)

2022 ◽  
Vol 148 ◽  
pp. 107695
Author(s):  
Lixian Liu ◽  
Huiting Huan ◽  
Andreas Mandelis ◽  
Le Zhang ◽  
Chengfei Guo ◽  
...  

2022 ◽  
Vol 808 ◽  
pp. 152141
Author(s):  
Jing Wei ◽  
Xinying Zhang ◽  
Longlong Xia ◽  
Wenping Yuan ◽  
Zhanyan Zhou ◽  
...  

2022 ◽  
Author(s):  
Lukas Siebler ◽  
Torben Rathje ◽  
Maurizio Calandri ◽  
Konstantinos Stergiaropoulos ◽  
Bernhard Richter ◽  
...  

Operators of event locations are particularly affected by a pandemic. Resulting restrictions may cause uneconomical business. With previous models, only an incomplete quantitative risk assessments is possible, whereby no suitable restrictions can be derived. Hence, a mathematical and statistical model has been developed in order to link measurement data of substance dispersion in rooms with epidemiological data like incidences, reproduction numbers, vaccination rates and test qualities. This allows a first time overall assessment of airborne infection risks in large event locations. In these venues displacement ventilation concepts are often implemented. In this case simplified theoretical assumptions fail for the prediction of relevant airflows for infection processes. Thus, with locally resolving trace gas measurements and specific data of infection processes, individual risks can be computed more detailed. Via inclusion of many measurement positions, an assessment of entire event locations is possible. Embedding the overall model in a flexible application, daily updated epidemiological data allow latest calculations of expected new infections and individual risks of single visitors for a certain event. With this model, an instrument has been created that can help policymakers and operators to take appropriate measures and to check restrictions for their effect.


2022 ◽  
Author(s):  
Lukas Siebler ◽  
Maurizio Calandri ◽  
Torben Rathje ◽  
Konstantinos Stergiaropoulos

This study introduces a principle, which unifies two experimental methods for airborne indoor virus-transmissions adapted to several ventilation measures. A first-time comparison of mechanical/natural ventilation and air purifiers with regard to infection risks is achieved. Effortful computational fluid dynamics demand detailed boundary conditions for accurate calculations of indoor airflows, which are often unknown. Hence a suitable, simple and generalized experimental set up for identifying the spatial and temporal infection risk for different ventilation measures is required. A trace gas method is suitable for mechanical and natural ventilation with outdoor air exchange. For an accurate assessment of air purifiers based on filtration a surrogate particle method is appropriate. The release of a controlled rate of either trace gas or particles simulates an infectious person releasing virus material. Surrounding substance concentration measurements identify the neighborhood exposure. One key aspect of the study is to prove that the requirement of concordant results of both methods is fulfilled. This is the only way to ensure that the comparison of different ventilation measures described above is reliable. Two examples (a two person office, several classrooms) show how practical both methods are and how the principle is applicable for different types and sizes of rooms.


2022 ◽  
Vol 19 (1) ◽  
pp. 165-185
Author(s):  
Juliana Gil-Loaiza ◽  
Joseph R. Roscioli ◽  
Joanne H. Shorter ◽  
Till H. M. Volkmann ◽  
Wei-Ren Ng ◽  
...  

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.


Author(s):  
Rohini Mattoo

Abstract Soil bacteria contribute effectively to key biogeochemical reactions in the soil rhizosphere. They support plants in the rhizosphere to adapt quickly to changing climatic conditions. Differences in root exudates, trace gas chemistry, chemical compounds and nutrient exchange contribute to the recruitment of diverse microorganisms by plant roots. This review highlights the importance of characterizing novel microorganisms to support sustainable agricultural practices. We discuss about tools for characterizing microbes and agricultural practices that influence microbial diversity, and have reviewed how microorganisms may have important but unidentified roles in climate change. Beneficial microbes could improve the turnover of carbon, nitrogen, phosphorus and other minerals thereby avoiding the use of chemical inputs, which are not only causing serious environmental harm but also pose danger to human and animal health.


2021 ◽  
Vol 14 (12) ◽  
pp. 8041-8067
Author(s):  
Merve Polat ◽  
Jesper Baldtzer Liisberg ◽  
Morten Krogsbøll ◽  
Thomas Blunier ◽  
Matthew S. Johnson

Abstract. The development of laser spectroscopy has made it possible to measure minute changes in the concentrations of trace gases and their isotopic analogs. These single or even multiply substituted species occur at ratios from percent to below parts per million and contain important information concerning trace gas sources and transformations. Due to their low abundance, minimizing spectral interference from other gases in a mixture is essential. Options including traps and membranes are available to remove many specific impurities. Methods for removing CH4, however, are extremely limited as methane has low reactivity and adsorbs poorly to most materials. Here we demonstrate a novel method for CH4 removal via chlorine-initiated oxidation. Our motivation in developing the technique was to overcome methane interference in measurements of N2O isotopic analogs when using a cavity ring-down spectrometer. We describe the design and validation of a proof-of-concept device and a kinetic model to predict the dependence of the methane removal efficiency on the methane concentration [CH4], chlorine photolysis rate JCl2, chlorine concentration [Cl2] and residence time tR. The model was validated by comparison to experimental data and then used to predict the possible formation of troublesome side products and by-products including CCl4 and HCl. The removal of methane could be maintained with a peak removal efficiency >98 % for ambient levels of methane at a flow rate of 7.5 mL min−1 with [Cl2] at 50 ppm. These tests show that our method is a viable option for continuous methane scrubbing. Additional measures may be needed to avoid complications due to the introduction of Cl2 and formation of HCl. Note that the method will also oxidize most other common volatile organic compounds. The system was tested in combination with a cavity ring-down methane spectrometer, and the developed method was shown to be successful at removing methane interference.


2021 ◽  
Vol 12 (1) ◽  
pp. 73
Author(s):  
Yue Hou ◽  
Kejin Huang

The measurement accuracy of trace gas detection based on infrared absorption spectroscopy is influenced by the overlap of absorption lines. A method for correcting the interference of overlapping absorption lines using second harmonic spectral reconstruction (2f-SR) is proposed to improve the measurement accuracy. 2f-SR includes three parts: measurement of gas temperature and use of the differences in temperature characteristics of absorption lines to correct the temperature error, 2f signal restoration based on laser characteristics to eliminate the influence of waveform change on overlapping absorption lines, and fast multi-peak fitting for the separation of interference from overlapping absorption lines. The CH4 measurement accuracy based on overlapping absorption lines is better than 0.8% using 2f-SR. 2f-SR has a lower minimum detection limit (MDL) and a higher detection accuracy than the separation of overlapping absorption lines based on the direct absorption method. The MDL is reduced by two to three orders of magnitude and reaches the part per million by volume level. 2f-SR has clear advantages for correcting the interference of overlapping absorption lines in terms of both MDL and measurement accuracy.


Sign in / Sign up

Export Citation Format

Share Document