scholarly journals Progress in Immunoassays for Serum Prolactin: Evidence from the UK External Quality Assessment Scheme (EQAS) 1980-1989

Author(s):  
I. Harming ◽  
J. Seth ◽  
R. R. A. Bacon ◽  
W. M. Hunter ◽  
R. Al-Sadie
Author(s):  
G H Beastall ◽  
K M Ferguson ◽  
D ST J O'reilly ◽  
J Seth ◽  
B Sheridan

The measurement of serum follicle stimulating hormone (FSH) and luteinising hormone (LH), together with the appropriate sex steroid, is of great value in the investigation of delayed and precocious puberty, hypogonadism, subfertility, polycystic ovarian disease and hypothalamic-pituitary disorders. Dynamic function testing of the hypothalamic-pituitary-gonadal axis should be restricted to a few defined situations. Sequential LH measurements, either in serum or in urine, may be used to time ovulation during artificial insemination or in vitro fertilisation programmes. No special precautions are necessary when sampling for FSH and LH measurement; serum is preferred to plasma and should be stored frozen before assay. Aliquots of timed urine specimens of known volume should be stored frozen without preservative. Gonadotropin results should be available within 2–3 weeks; laboratories unable to meet this schedule are advised to send their samples to a Regional Centre for assay. Reagents for the radioimmunoassay of FSH and LH are readily available, and standard techniques have been developed for their use. Laboratories using ‘in-house’ methods should pay particular attention to the matrix used for preparing standard solutions, the purification of radioligands and the optimisation of the separation system. Low cost matched reagents of proven performance are available in kit form from the Chelsea Hospital for Women; several commercial kits are also available, although few are widely used in the UK. The overall performance of laboratories in the UK External Quality Assessment Scheme (EQAS) for FSH and LH has remained steady for several years. Of the 130 participants, only about 15% in each scheme have ‘good’ performance (cumulative bias less than 10%, plus cumulative variability of bias less than 10%), whilst a similar proportion have ‘unacceptable’ performance (cumulative bias greater than 20% and/or cumulative variability of bias greater than 25%). The remaining 70% of laboratories have ‘adequate’ performance but are at risk of producing results that are clinically misleading. Within any one method group, the performance of FSH and LH assays are closely related. Optimal assay performance depends upon sensible laboratory management to ensure skilled operators, a regular programme of reagent/kit renewal, comprehensive internal and external quality assessment, and attention to detail in all aspects of gonadotrophin assay. The working range of each individual assay should be defined and no absolute result reported from outside this range. Mean intra-assay and interassay coefficients of variation on selected human serum quality control pools should be better than 8% and 15%, respectively, for both gonadotrophins. All laboratories performing FSH and LH assays should belong to the UK EQAS for gonadotrophins. Immunometric assays, using monoclonal antibodies, will supersede radioimmunoassays for FSH and LH during the next few years. Some of these assays will have non-isotopic labels.


2014 ◽  
Vol 40 (02) ◽  
pp. 261-268 ◽  
Author(s):  
David Perry ◽  
Tony Cumming ◽  
Anne Goodeve ◽  
Marian Hill ◽  
Ian Jennings ◽  
...  

Molecular genetic analysis of families with hemophilia and other heritable bleeding disorders is a frequently requested laboratory investigation. In the United Kingdom, laboratories undertaking genetic testing must participate in a recognized external quality assessment scheme for formal accreditation. The UK National External Quality Assessment Scheme (UK NEQAS) for heritable bleeding disorders was established in its current format in 2003, and currently has 27 registered participants in the United Kingdom, the European Union (EU), and the non-EU countries. Two exercises per annum are circulated to participants comprising either whole blood or DNA isolated from cell lines, and laboratories are allowed 6 weeks to analyze the samples and generate a report. Reports are assessed by a panel comprising clinicians and scientists with expertise in this area. Samples to date have involved analysis of the F8 gene (10 exercises), the F9 gene (4 exercises), and the VWF gene (3 exercises) and have comprised a wide spectrum of mutations representing the routine workload encountered in the molecular genetics laboratory. The majority of laboratories in each exercise passed, but a small number did not and reasons for failing included clerical errors, genotyping inaccuracies, and a failure to correctly interpret data. Overall we have seen an improvement in quality of reports submitted for assessment, with a more concise format that will be of value to referring clinicians and counsellors. Informal feedback from participants has been very positive.


Author(s):  
Robby A Bacchus ◽  
David G Bullock ◽  
George A Noy ◽  
Thomas P Whitehead

The establishment and first 7 years' operation of an external quality assessment scheme for clinical chemistry in the Middle East region are described. The scheme utilises specimens distributed previously in the UK, and the performance of participating laboratories is assessed relative to the UK consensus values, taking account of method. Variance Index scoring has been used to quantitate performance, and there has been an improvement in average scores during the operation of the scheme. There are currently 88 participants, though some laboratories which failed to return results regularly were removed from the scheme. The consensus values from the scheme itself have now been validated, and in future the scheme should operate independently.


2006 ◽  
Vol 96 (11) ◽  
pp. 597-601 ◽  
Author(s):  
Anne Goodeve ◽  
Marian Hill ◽  
Ian Jennings ◽  
Steve Kitchen ◽  
Isobel Walker ◽  
...  

SummaryMolecular genetic analysis of families with haemophilia and other inherited bleeding disorders is nowa common laboratory investigation. In contrast to phenotypic testing in which strict quality control is adhered to, in haemophilia molecular genetic testing there has been a lack of any external quality assurance schemes. In 1998 the UK National External Quality Assessment Scheme (UK NEQAS) established a pilot quality assurance scheme for molecular genetic testing in haemophilia. Results from three initial surveys highlighted problems with the quality of samples when used to screen for the intron 22 inversion within the F8 gene. The scheme was re-launched in 2003, and since that time there have been five exercises involving whole blood or immortalised cell line DNA. The results together with an overall summary of the exercise are subsequently returned to participants. Exercises to date have focused exclusively on haemophilia A and QA, material has included screening for the intron 1 and intron 22 inversions as well as sequence analysis. A paper exercise circulated in 2003 highlighted problems with the format of reports and, following feedback to participants, onlya single error has been made in the subsequent four exercises. Participating laboratories now receive QA material every six months. Immortalised cell line material was introduced in 2005 and was shown to perform well. This will allow expansion of the scheme and a reduction in the dependence on blood donation.


Sign in / Sign up

Export Citation Format

Share Document