scholarly journals Double Ring in Cochlear Otosclerosis: A Limit to Cochlear Implantation? The Solution Is the Surgical Approach

2019 ◽  
pp. 014556131989560
Author(s):  
Daniela Messineo ◽  
Massimo Ralli ◽  
Antonio Greco ◽  
Arianna Di Stadio

We present a case of a 50-year patient with a severe form of otosclerosis (double ring) that was successfully implanted. We used a bone-anchored hearing implant for restoring the hearing in the right side and a cochlear implant in the left side; both surgeries did not show any complications. For reducing the risk of a secondary bone ossification related to the trauma of cochleostomy for electrode’s insertion, we used a round window approach. The patient recovered a normal auditory threshold and normal speech perception capacity both in silence and noise conditions 1 year after surgery.

2014 ◽  
Vol 36 (v1supplement) ◽  
pp. 1 ◽  
Author(s):  
Douglas D. Backous

The indications for cochlear implantation continue to extend to patients with increased levels of residual hearing. Single-sided deafness and tinnitus are currently under various clinical trials as even further expansion of the application of cochlear implant device and programming technology is underway. This video details a round window and hearing preservation approach for cochlear implant placement, and incorporates the most recent advances in surgical technique.The video can be found here: http://youtu.be/bDqkbboXrU4.


Author(s):  
Beomcho Jun ◽  
Sunwha Song

Abstract Objective This paper describes the construction of portals for electrode placement during cochlear implantation and emphasises the utility of pre-operative temporal bone three-dimensional computed tomography. Methods Temporal bone three-dimensional computed tomography was used to plan portal creation for electrode insertion. Results Pre-operative temporal bone three-dimensional computed tomography can be used to determine the orientation of temporal bone structures, which is important for mastoidectomy, posterior tympanotomy and cochleostomy, and when using the round window approach. Conclusion It is essential to create appropriate portals (from the mastoid cortex to the cochlea) in a step-by-step manner, to ensure the safe insertion of electrodes into the scala tympani. Pre-operative three-dimensional temporal bone computed tomography is invaluable in this respect.


2021 ◽  
pp. 014556132110516
Author(s):  
Mohammad Almohammad ◽  
Tala Tasabehji ◽  
Abdulrahman Awad ◽  
Ibrahem Hanafi

Background: We aim to report a rare case of a herniated mastoid segment of the facial nerve that was accidently discovered during cochlear implantation surgery and how altering the surgery plan could achieve the implantation while preserving the nerve. Case presentation: A four-year-old girl presented with profound bilateral sensorineural hearing loss that did not completely resolve after 2 years of using hearing aids was scheduled for cochlear implantation surgery in the right ear. During surgery, a herniated mastoid segment of the facial nerve took an anterior course and obstructed the access to the round window. Conclusion: When a traditional posterior tympanotomy approach in cochlear implantation surgery is limited in cases of a herniated facial nerve, a tunnel created near the inferior part of the posterior wall of the auditory canal provided safe insertion of the electrode. It also permitted placement of a piece of fascia between the electrode and the facial nerve, therefore, protecting the facial nerve from electrical stimuli.


2021 ◽  
Vol 12 ◽  
Author(s):  
Keita Tsukada ◽  
Shin-ichi Usami

Background: The development of less traumatic surgical techniques, such as the round window approach (RWA), as well as the use of flexible electrodes and post-operative steroid administration have enabled the preservation of residual hearing after cochlear implantation (CI) surgery. However, consideration must still be given to the complications that can accompany CI. One such potential complication is the impairment of vestibular function with resulting vertigo symptoms. The aim of our current study was to examine the changes in vestibular function after implantation in patients who received CI using less traumatic surgery, particularly the RWA technique.Methods: Sixty-six patients who received CI in our center were examined by caloric testing, cervical vestibular evoked myogenic potential (cVEMP) and ocular VEMP (oVEMP) before or after implantation, or both, to obtain data on semicircular canal, saccular and utricular function, respectively. Less traumatic CI surgery was performed by the use of the RWA and insertion of flexible electrodes such as MED-EL FLEX soft, FLEX 28, and FLEX 24 (Innsbruck, Austria).Results: Caloric response and the asymmetry ratio of cVEMP and oVEMP were examined before and after implantation using less traumatic surgical techniques. Compared with before implantation, 93.9, 82.4, and 92.5% of the patients showed preserved vestibular function after implantation based on caloric testing, cVEMP and oVEMP results, respectively. We also examined the results for vestibular function by a comparison of the 66 patients using the RWA and flexible electrodes, and 17 patients who underwent cochleostomy and insertion of conventional or hard electrodes. We measured responses using caloric testing, cVEMP and oVEMP in patients after CI. There were no differences in the frequencies of abnormal caloric and oVEMP results in the implanted ears between the RWA and cochleostomy. On the other hand, the frequency of abnormal cVEMP responses in the implanted ears in the patients who received implantation by cochleostomy was significantly higher than that in the patients undergoing surgery using the RWA.Conclusion: Patients receiving CI using less traumatic surgical techniques such as RWA and flexible electrodes have reduced risk of damage to vestibular function.


2009 ◽  
Vol 130 (6) ◽  
pp. 696-701 ◽  
Author(s):  
Heinz-Dieter Kluenter ◽  
Ruth Lang-Roth ◽  
Dirk Beutner ◽  
Karl-Bernd Hüttenbrink ◽  
Orlando Guntinas-Lichius

2018 ◽  
Vol 43 (6) ◽  
pp. 1535-1540 ◽  
Author(s):  
Jae-Yoon Kang ◽  
Jee-Hye Chung ◽  
Hee-Sung Park ◽  
Yong-Ho Park ◽  
Jin Woong Choi

2019 ◽  
Vol 277 (2) ◽  
pp. 343-350 ◽  
Author(s):  
Floris Heutink ◽  
Berit M. Verbist ◽  
Lucas H. M. Mens ◽  
Wendy J. Huinck ◽  
Emmanuel A. M. Mylanus

Abstract Purpose In cochlear implantation (CI), the two factors that are determined by the surgeon with a potential significant impact on the position of the electrode within the cochlea and the potential outcome, are the surgical technique and electrode type. The objective of this prospective study was to evaluate the position of the slim, perimodiolar electrode (SPE), and to study the influence of the SPE position on CI outcome. Methods Twenty-three consecutively implanted, adult SPE candidates were included in this prospective cohort study conducted between December 2016 and April 2019. Mean age at surgery was 59.5 years. Mean preoperative residual hearing was 92.2 dB. Intra-operative fluoroscopy and high-resolution computed tomography scans were performed to evaluate electrode position after insertion using a cochleostomy (CS) approach. Follow-up was 12 months after implantation; residual hearing (6–8 weeks) and speech perception (6–8 weeks and 12 months) were evaluated in relation to the intracochlear SPE position. Results In most patients in whom the SPE was positioned in the scala tympani residual hearing was preserved [mean absolute increase in PTA of 4.4 dB and 77.2% relative hearing preservation (RHP%)]. Translocation into the scala vestibuli occurred in 36% of the insertions, resulting in a mean absolute increase in PTA of 17.9 dB, and a RHP% of 19.2%. Participants with a translocation had poorer speech perception scores at 12-month follow-up. Conclusion Given the incidence of CS-associated translocations with the SPE and the negative effect on outcome, it is advised to insert the SPE using the (extended) round window approach.


2011 ◽  
Vol 22 (09) ◽  
pp. 567-577 ◽  
Author(s):  
Christina L. Runge ◽  
Jamie Jensen ◽  
David R. Friedland ◽  
Ruth Y. Litovsky ◽  
Sergey Tarima

Background: The challenges associated with auditory neuropathy spectrum disorder (ANSD) are due primarily to temporal impairment and therefore tend to affect perception of low- to midfrequency sounds. A common treatment option for severe impairment in ANSD is cochlear implantation, and because the degree of impairment is unrelated to degree of hearing loss by audiometric thresholds, this population may have significant acoustic sensitivity in the contralateral ear. Clinically, the question arises as to how we should treat the contralateral ear in this population when there is acoustic hearing—should we plug it, amplify it, implant it, or leave it alone? Purpose: The purpose of this study was to examine the effects of acute amplification and plugging of the contralateral ear compared to no intervention in implanted children with ANSD and aidable contralateral hearing. It was hypothesized that due to impaired temporal processing in ANSD, contralateral acoustic input would interfere with speech perception achieved with the cochlear implant (CI) alone; therefore, speech perception performance will decline with amplification and improve with occlusion. Research Design: Prospective within-subject comparison. Adaptive speech recognition thresholds (SRTs) for monosyllable and spondee word stimuli were measured in quiet and in noise for the intervention configurations. Study Sample: Nine children treated at the Medical College of Wisconsin Koss Cochlear Implant Program participated in the study. Inclusion criteria for this study were children diagnosed with ANSD who were unilaterally implanted, had aidable hearing in the contralateral ear (defined as a three-frequency pure-tone average of ≤80 dB HL), had at least 1 yr of cochlear implant experience, and were able to perform the speech perception task. Intervention: We compared SRT with the CI alone to SRTs with interventions of cochlear implant with a contralateral hearing aid (CI+HA) and cochlear implant with a contralateral earplug (CI+plug). Data Collection and Analysis: SRTs were measured and compared within subjects across listening conditions. Within-subject comparisons were analyzed using paired t-tests, and analyses of predictive variables for effects of contralateral intervention were analyzed using linear regression. Results: Contrary to the hypothesis, the bimodal CI+HA configuration showed a significant improvement in mean performance over the CI-alone configuration in quiet (p = .04). In noise, SRTs were obtained for six subjects, and no significant bimodal benefit was observed (p = .09). There were no consistent effects of occlusion observed across subjects and stimulus conditions. Degree of bimodal benefit showed a significant relationship with performance with the CI alone, with greater bimodal benefit associated with poorer CI-alone performance (p = .01). This finding, however, was limited by floor effects. Conclusions: The results of this study indicate that children with ANSD who are experienced cochlear implant users may benefit from contralateral amplification, particularly for moderate cochlear implant performers. It is unclear from these data whether long-term contralateral hearing aid use in real-world situations would ultimately benefit this population; however, a hearing aid trial is recommended with assessment of bimodal benefit over time. These data may help inform clinical guidelines for determining optimal hearing configurations for unilaterally implanted children with ANSD, particularly when considering candidacy for sequential cochlear implantation.


1999 ◽  
Vol 113 (5) ◽  
pp. 458-463 ◽  
Author(s):  
J. Graham ◽  
C. Lynch ◽  
B. Weber ◽  
L. Stollwerck ◽  
J. Wei ◽  
...  

AbstractWe present our experience using the Clarion® magnetless multichannel cochlear implant with a woman profoundly deafened following bilateral acoustic neuromata as a consequence of neurofibromatosis 2 (NF2). The right neuroma had been previously removed without an attempt at neural preservation. On the left, however, a posterior fossa approach had been taken with the aim of preserving hearing. Although the left cochlear nerve appeared to be undamaged at the end of the operation, no hearing thresholds could be elicited on post-operative audiometry, because of damage either to the cochlear nerve or to the blood supply to the cochlea. Round window electrical stimulation subsequently produced a perception of sound, confirming that the cochlear nerve was capable of functioning and that a cochlear implant would be effective. Because she would need regular magnetic resonance imaging (MRI) to monitor existing and future NF2 lesions, it was decided to use a magnetless Clarion® implant, which has been shown to be MRI compatible. We report our experience of using the device in this case and discuss some of the issues related to the provision of cochlear implants to patients with NF2.


2017 ◽  
Vol 38 (7) ◽  
pp. 962-969 ◽  
Author(s):  
Mun Young Chang ◽  
Yoon Chan Rah ◽  
Jun Jae Choi ◽  
Shin Wook Woo ◽  
Yu-Jung Hwang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document