scholarly journals The Use of End-tidal Carbon Dioxide Monitoring to Confirm Endotracheal Tube Placement in Adult and Paediatric Intensive Care Units in Australia and New Zealand

2004 ◽  
Vol 32 (5) ◽  
pp. 672-675 ◽  
Author(s):  
P. D. Erasmus
2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Yongil Cho ◽  
Wonhee Kim ◽  
Tae Ho Lim ◽  
Hyuk Joong Choi ◽  
Jaehoon Oh ◽  
...  

Introduction. Capnometer can be readily malfunctioned by fluid exposure during treatment of critically ill patients. This study aimed to determine whether placing capnometer distant from the endotracheal tube by connecting direct connect catheter mount (DCCM) is effective in yielding reliable end-tidal carbon dioxide (ETCO2) by reducing capnometer malfunctioning caused by water exposure. Methods. In 25 healthy adults, a prospective, open label, crossover study was conducted to examine the effect of DCCM in mainstream and microstream capnometers under water exposing conditions. The primary endpoint was the comparison of ETCO2 between proximal DCCM (pDCCM) and distal DCCM (dDCCM). Results. For mainstream capnometers, mean ETCO2 was significantly (p < 0.001) higher in dDCCM compared to pDCCM under water exposing conditions (29.5 vs. 19.0 with 5 ml; 33.8 vs. 21.2 with 10 ml; mmHg). Likewise, for microstream capnometers, ETCO2 was greatly higher (p < 0.001) in dDCCM compared to pDCCM (30.5 vs. 13.9 with 5 ml; 29.9 vs.11.4 with 10 mL; mmHg). ETCO2 measured by dDCCM was reliable in microstream settings, whereas it was unreliable in mainstream (correlation coefficient 0.88 vs. 0.27). Conclusions. Application of DCCM onto the capnometer setting seems to be effective in reducing capnometer malfunctioning under fluid exposing conditions, which is obvious in microstream capnometer by producing more reliable ETCO2.


PEDIATRICS ◽  
1998 ◽  
Vol 101 (4) ◽  
pp. 648-653 ◽  
Author(s):  
Henry J. Rozycki ◽  
Gregory D. Sysyn ◽  
M. Kathy Marshall ◽  
Raymond Malloy ◽  
Thomas E. Wiswell

2006 ◽  
Vol 105 (6) ◽  
pp. 1081-1086 ◽  
Author(s):  
Frederick W. Cheney ◽  
Karen L. Posner ◽  
Lorri A. Lee ◽  
Robert A. Caplan ◽  
Karen B. Domino

Background The authors used the American Society of Anesthesiologists Closed Claims Project database to determine changes in the proportion of claims for death or permanent brain damage over a 26-yr period and to identify factors associated with the observed changes. Methods The Closed Claims Project is a structured evaluation of adverse outcomes from 6,894 closed anesthesia malpractice claims. Trends in the proportion of claims for death or permanent brain damage between 1975 and 2000 were analyzed. Results Claims for death or brain damage decreased between 1975 and 2000 (odds ratio, 0.95 per year; 95% confidence interval, 0.94-0.96; P &lt; 0.01). The overall downward trend did not seem to be affected by the use of pulse oximetry and end-tidal carbon dioxide monitoring, which began in 1986. The use of these monitors increased from 6% in 1985 to 70% in 1989, and thereafter varied from 63% to 83% through the year 2000. During 1986-2000, respiratory damaging events decreased while cardiovascular damaging events increased, so that by 1992, respiratory and cardiovascular damaging events occurred in approximately the same proportion (28%), a trend that continued through 2000. Conclusion The significant decrease in the proportion of claims for death or permanent brain damage from 1975 through 2000 seems to be unrelated to a marked increase in the proportion of claims where pulse oximetry and end-tidal carbon dioxide monitoring were used. After the introduction and use of these monitors, there was a significant reduction in the proportion of respiratory and an increase in the proportion of cardiovascular damaging events responsible for death or permanent brain damage.