On the effect of geometry of w-wave trenches on film cooling performance of gas turbine blades

Author(s):  
Alireza Bakhshinejad Bahambari ◽  
Mohammad Hassan Kayhani ◽  
Mahmood Norouzi

In the present study, three types of w-wave trenches with different amplitude configurations are compared with transverse trench (TT), and the use of variable radius fillet (VRF) on downstream lips at different blowing ratio is numerically investigated to measure heat transfer coefficient, and cooling effectiveness. The numerical results are obtained by three-dimensional Reynolds average Navier–Stokes equations (RANS) while employing shear stress transport turbulence models, which are validated by comparing with experimental data. The trench width is kept constant in all cases, yet the three different amplitudes and variable fillet radiuses offered a variety of designs in trench film cooling. The results showed that w-wave trenches impressively improved film cooling effectiveness over the transverse trench, and utilizing fillets at downstream lips of the trench caused significant enhancement on both lateral averaged and centerline cooling performance. Due to the w-wave trench configuration, anti-counter-rotating vortices responsible for pushing coolant film toward the near-wall were formed throughout of downstream wall of the trench, and the cooling flow thus had a more uniform structure. The heat transfer coefficient distributions of filleted w-wave trenches are observed to be more uniform than simple w-wave and transverse trench under all blowing ratio conditions. Moreover, enlargement of the fillet radius in Cases 2 and 3 yielded to the growth of centerline coolant flow, which in turn resulted in the improvement of film cooling effectiveness at all blowing ratios.

Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo

To investigate the effects of the inclined ribs on internal flow structure in film hole and the film cooling performance on outer surface, experimental and numerical studies are conducted on the effects of rib orientation angle on film cooling of compound cylindrical holes. Three coolant channel cases, including two ribbed cross-flow channels (135° and 45° angled ribs) and the plenum case, are studied under three blowing ratios (0.5, 1.0 and 2.0). 2D contours of film cooling effectiveness as well as heat transfer coefficient were measured by transient liquid crystal measurement technique (TLC). The steady RANS simulations with realizable k-ε turbulence model and enhanced wall treatment were performed. The results show that the spanwise width of film coverage is greatly influenced by the rib orientation angle. The spanwise width of the 45° rib case is obviously larger than that of the 135° rib case under lower blowing ratios. When the blowing ratio is 1.0, the area-averaged cooling effectiveness of the 135° rib case and the 45° rib case are higher than that of the plenum case by 38% and 107%, respectively. With the increase of blowing ratio, the film coverage difference between different rib orientation cases becomes smaller. The 45° rib case also produces higher heat transfer coefficient, which is higher than the 135° rib case by 3.4–8.7% within the studied blowing ratio range. Furthermore, the discharge coefficient of the 45° rib case is the lowest among the three cases. The helical motion of coolant flow is observed in the hole of 45° rib case. The jet divides into two parts after being blown out of the hole due to this motion, which induces strong velocity separation and loss. For the 135° rib case, the vortex in the upper half region of the secondary-flow channel rotates in the same direction with the hole inclination direction, which leads to the straight streamlines and thus results in lower loss and higher discharge coefficient.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Qi-jiao He ◽  
Gang Xie

The trailing edge of the high-pressure turbine blade presents significant challenges to cooling structure design. To achieve better cooling performance at turbine blade trailing edge, a novel ribbed cutback structure is proposed for trailing edge cooling, which has rib structures on the cutback surface for heat transfer enhancement. In this study, numerical simulations have been performed on the effects of V-shaped rib angle on the film cooling characteristics and flow physics. Three V-shaped rib angles of 30°, 45° and 60° are studied. The distributions of adiabatic cooling effectiveness and heat transfer coefficient are obtained under blowing ratios with the value of 0.5, 1.0 and 1.5 respectively. Due to the relatively small rib height, the effect of V-shaped ribs on the film cooling effectiveness is not notable. The disadvantage of V-shaped ribs mainly exhibits at the downstream area of cutback surface. With the increase of V-shaped rib angle, the film cooling effectiveness becomes lower, but the values are still above 0.9. The V-shaped ribs obviously enhance the heat transfer on trailing edge cutback surface. The area-averaged heat transfer coefficient of the V-rib case is higher than that of the smooth case by 26.3–41.2%. The 45° V-rib case has higher heat transfer intensity than the other two V-shaped rib cases under all the three blowing ratios. However, the heat transfer coefficient distribution of the 60° V-rib case is more uniform. The heat transfer intensity of the 30° V-rib case is higher in the downstream region than the other two cases, but lower in the upstream region in which the difference becomes smaller with the increase of blowing ratio. The 45° V-rib case and the 60° V-rib case both reach the maximum value of area-averaged heat transfer intensity under blowing ratio is 1.0. Under higher blowing ratio, the 30° V-rib case and the 45° V-rib case outperform 2.1% and 6.7% higher value relative to the 60° V-rib case respectively due to the smaller velocity gradient in the 60° V-rib case in the downstream.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.


Author(s):  
Rui-dong Wang ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Qi-ling Guo ◽  
...  

Heat transfer of the counter-inclined cylindrical and laid-back holes with and without impingement on the turbine vane leading edge model are investigated in this paper. To obtain the film cooling effectiveness and heat transfer coefficient, transient temperature measurement technique on complete surface based on double thermochromic liquid crystals is used in this research. A semi-cylinder model is used to model the vane leading edge which is arranged with two rows of holes. Four test models are measured under four blowing ratios including cylindrical film holes with and without impingement tube structure, laid-back film holes with and without impingement tube structure. This is the second part of a two-part paper, the first part paper GT2018-76061 focuses on film cooling effectiveness and this study will focus on heat transfer. Contours of surface heat transfer coefficient and laterally averaged result are presented in this paper. The result shows that the heat transfer coefficient on the surface of the leading edge is enhanced with the increase of blowing ratio for same structure. The shape of the high heat transfer coefficient region gradually inclines to span-wise direction as the blowing ratio increases. Heat transfer coefficient in the region where the jet core flows through is relatively lower, while in the jet edge region the heat transfer coefficient is relatively higher. Compared with cylindrical hole, laid-back holes give higher heat transfer coefficient. Meanwhile, the introduction of impingement also makes heat transfer coefficient higher compared with cross flow air intake. It is found that the heat transfer of the combination of laid-back hole and impingement tube can be very high under large blowing ratio which should get attention in the design process.


2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Akira Murata ◽  
Satomi Nishida ◽  
Hiroshi Saito ◽  
Kaoru Iwamoto ◽  
Yoji Okita ◽  
...  

Cooling at the trailing edge of a gas turbine airfoil is one of the most difficult problems because of its thin shape, high thermal load from both surfaces, hard-to-cool geometry of narrow passages, and at the same time demand for structural strength. In this study, the heat transfer coefficient and film cooling effectiveness on the pressure-side cutback surface was measured by a transient infrared thermography method. Four different cutback geometries were examined: two smooth cutback surfaces with constant-width and converging lands (base and diffuser cases) and two roughened cutback surfaces with transverse ribs and spherical dimples. The Reynolds number of the main flow defined by the mean velocity and two times the channel height was 20,000, and the blowing ratio was varied among 0.5, 1.0, 1.5, and 2.0. The experimental results clearly showed spatial variation of the heat transfer coefficient and the film cooling effectiveness on the cutback and land top surfaces. The cutback surface results clearly showed periodically enhanced heat transfer due to the periodical surface geometry of ribs and dimples. Generally, the increase of the blowing ratio increased both the heat transfer coefficient and the film cooling effectiveness. Within the present experimental range, the dimple surface was a favorable cutback-surface geometry because it gave the enhanced heat transfer without deterioration of the high film cooling effectiveness.


Author(s):  
Seung Il Baek ◽  
Savas Yavuzkurt

The objective of this study is to understand the effects of flow oscillations in the mainstream and film cooling jets on film cooling at various blowing ratios (0.5, 0.78, 1.0 and 1.5). These oscillations could be caused by the combustion instabilities. They are approximated in sinusoidal form for the current study. The effects of different frequencies (0, 2, 16, 32 Hz) on film cooling are investigated. Simulations are performed using URANS Realizable k-epsilon and LES Smagorinsky-Lilly turbulence models. The results indicate that if the frequencies of the mainstream and the jet flow are increased at a low average blowing ratio of M = 0.5, the adiabatic film cooling effectiveness is decreased and the heat transfer coefficient is increased due to increased disturbance in jet and main flow interaction with increasing frequency. It was observed that when the frequency of the mainstream and the cooling jet flow is increased at M = 0.5, the amplitude of the pressure difference between the mainstream and the plenum is increased resulting in increased amplitude of coolant flow rate oscillations leading to more jet lift off and more disturbance in the main flow and coolant interaction. Consequently, adiabatic film cooling effectiveness is decreased and heat transfer coefficient is increased. If the frequency of the mainstream is increased from 0 Hz to 2, 16, or 32 Hz at M = 0.5, the centerline effectiveness is decreased about 10%, 12%, or 47% and the spanwise-averaged Stanton number ratio is increased about 4%, 5%, or 9% respectively. If the frequencies of the main flow and the jet flow are increased at higher blowing ratios of M = 1.0 and 1.5, adiabatic effectiveness is increased and the spanwise-averaged heat transfer coefficient are decreased. Under steady flow conditions jet lift off is generated for these high blowing ratios. If the frequency of the mainstream and the jet flow is increased, the amplitude of coolant jet flow rate oscillation is increased for the same reason as mentioned above for M = 0.5. This leads to less jet lift off during the cycle resulting in more frequent coolant contact with the wall and consequently increased centerline effectiveness as frequency increases. In addition, the entrainment of hot gases underneath the jet doesn’t lead to higher mixing between the hot mainstream and the coolant and this results in decreased heat transfer coefficient. This is also indicated by the turbulent kinetic energy levels. Some representative results are: when the frequency of the main flow is increased from 0 Hz to 2, 16, or 32 Hz at M = 1.0, the centerline effectiveness is increased about 8%, 19%, or 320%. Also, if the oscillation frequency is increased from 2 Hz to 16, or 32 Hz at M = 1.0, the spanwise-averaged Stanton number ratio is decreased around 2%, to 5% respectively. It seems like the cut off point for low and high blowing ratio behavior of cooling jets is around M = 0.78.


1999 ◽  
Vol 121 (2) ◽  
pp. 225-232 ◽  
Author(s):  
R. J. Goldstein ◽  
P. Jin ◽  
R. L. Olson

A special naphthalene sublimation technique is used to study the film cooling performance downstream of one row of holes of 35 deg inclination angle with 3d hole spacing and relatively small hole length to diameter ratio (L/d = 6.3). Both film cooling effectiveness and mass/heat transfer coefficient are determined for blowing rates from 0.5 to 2.0 with density ratio of 1.0. The mass transfer coefficient is measured using pure air film injection, while the film cooling effectiveness is derived from comparison of mass transfer coefficients obtained following injection of naphthalene-vapor-saturated air with those from pure air injection. This technique enables one to obtain detailed local information on film cooling performance. The laterally averaged and local film cooling effectiveness agree with previous experiments. The difference between mass/heat transfer coefficients and previous heat transfer results indicates that conduction error may play an important role in the earlier heat transfer measurements.


2001 ◽  
Vol 7 (3) ◽  
pp. 153-164 ◽  
Author(s):  
Ping-Hei Chen ◽  
Min-Sheng Hung ◽  
Pei-Pei Ding

In order to explore the effect of blowing ratio on film cooling over a convex surface, the present study adopts the transient liquid crystal thermography for the film cooling measurement on a straight circular hole configuration. The test piece has a strength of curvature(2r/D)of 92.5, pitch to diameter ratio(P/D)of 3 and streamwise injection angle(γ)of35∘All measurements were conducted under the mainstream Reynolds number(Red)of 1700 with turbulence intensity(Tu)of 3.8%, and the density ratio between coolant and mainstream(ρc/ρm)is 0.98. In current study, the effect of blowing ratio(M)on film cooling performance is investigated by varying the range of blowing ratio from 0.5 to 2.0. Two transient tests of different injection flow temperature were conducted to obtain both detailed heat transfer coefficient and film cooling effectiveness distributions of measured region. The present measured results show that both the spanwise averaged heat transfer coefficient and film cooling effectiveness increase with decreased blowing ratio.


Author(s):  
Yukiko Agata ◽  
Toshihiko Takahashi ◽  
Eiji Sakai ◽  
Koichi Nishino

To augment the thermal efficiency of combined power generation plants, the turbine inlet temperature of an industrial gas turbine has been increased. Cooling technology plays a vital role in the durability of gas turbine blades in situations in which the turbine inlet temperature exceeds the allowable temperature of the blade material. Cooling air is also directly associated with the reduction in thermal efficiency because bleed air from the compressor is used for turbine cooling. Thus, improvement in cooling performance has a marked impact on the further augmentation of thermal efficiency by increasing turbine inlet temperature. To evaluate film cooling performance on the basis of heat flux reduction, it is necessary to accurately estimate both heat transfer coefficient and adiabatic film cooling effectiveness. Most studies of film cooling, however, have focused on improving adiabatic film cooling effectiveness. In contrast, there are few studies focusing on heat transfer coefficient. One of the reasons for this is that adiabatic film cooling effectiveness is a performance parameter unique to film cooling. To preliminarily estimate the heat flux through a blade, heat transfer coefficient without film cooling can still be used as substitute. Moreover, the accurate CFD prediction of heat transfer coefficient with film cooling is difficult, compared with the evaluation of adiabatic film cooling effectiveness. Therefore, in this study, we addressed the CFD prediction of heat transfer coefficient with film cooling on a flat plate, and discussed its feasibility. Recent gas turbine blades operated at a turbine inlet temperature of over 1300 degree Celsius employ internal convection cooling with ribbed passages and external film cooling. These cooling technologies have been studied extensively, particularly regarding their individual effects. On the other hand, there are few investigations on the interaction between internal convection cooling and the film cooling. Although most of such film-cooling studies employed stagnant plenums to bleed cooling air, some researchers including the present authors have shown the marked impact of the conditions for supplying coolant air on film cooling performance. In this study, we focus particularly on the influence of internal rib orientation on external film cooling performance along the blade outer surface. CFD analysis is used to resolve the flow fields of the flat plate film cooling and to clarify the influence of rib orientation on heat-transfer.


Author(s):  
Ying-Ni Zhai ◽  
Cun-Liang Liu ◽  
Yi-Hong He ◽  
Zhi-Xiang Zhou

AbstractFilm cooling performances of laidback hole and laidback fan-shaped hole have been investigated using transient liquid crystal measurement technique. For film cooling of laidback hole, the increase of inclination angle reduces the film cooling effectiveness under small blowing ratio, while produces better film coverage and higher film cooling effectiveness under larger blowing ratios. Heat transfer coefficient is higher in the upstream region of laidback hole film cooling with large inclination angle, while laidback hole with small inclination angle has relatively higher heat transfer coefficient in the downstream region. The increase of inclination angle reduces the film cooling effectiveness and heat transfer coefficient of laidback fan-shaped hole film cooling, especially in the upstream region. Increase of inclination angle is beneficial to the thermal protection of laidback hole film cooling under large blowing ratio. Film hole with large inclination angle has larger discharge coefficient due to smaller aerodynamic loss in the hole.


Sign in / Sign up

Export Citation Format

Share Document