Femtosecond-assisted laser in situ keratomileusis for high myopia correction: Long-term follow-up outcomes.

2019 ◽  
Vol 30 (3) ◽  
pp. 446-454 ◽  
Author(s):  
Alfredo Vega-Estrada ◽  
Jorge L Alio

Objective: Report the outcomes of laser in situ keratomileusis (LASIK) for high myopia correction after long-term follow-up. Methods: Retrospective, consecutive, clinical study including 70 eyes that underwent LASIK using a 500 Hertz (Hz) repetition rate excimer laser and femtosecond technology for flap creation. Visual, refractive, corneal aberrations, and correlation among the variables were evaluated during 3 years. In addition, 34 eyes were followed during 5 years. Results: Significant improvement of 17 logMAR lines was observed in uncorrected vision at 5 years (p < 0.01). This was consistent with spherical equivalent reduction that came from mean preoperative –7.79 diopters (D) to 5 years postoperative –0.24 D (p < 0.01). Significant induction of primary spherical aberration and coma aberration was also found (p < 0.01) at 3 months with levels of 0.61 µm and 0.47 µm, respectively, with no further changes at 5 years (p > 0.05). Pearson correlation showed that the amount of high-order aberrations at 3 months postoperativeley was significantly correlated with the changes in the keratometry throughout the 5 years (delta K) (R2 0.242 p = 0.05). Finally, preoperative corneal asphericity showed an inverse correlation with the delta K (R2 –308 p = 0.01). Conclusions: Results from this study suggests that LASIK for high myopia correction using 500 Hz repetition rate excimer laser provides stable visual, refractive and aberrometric results after 5 years of follow-up. A more prolate cornea and the amount of higher-order aberrations induced after LASIK are factors that negatively impact in the long-term stability of the procedure.

2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Tetsuya Ikeda ◽  
Kimiya Shimizu ◽  
Akihito Igarashi ◽  
Sumie Kasahara ◽  
Kazutaka Kamiya

Purpose. To assess the long-term clinical outcomes of conventional laser in situ keratomileusis (LASIK) for moderate to high myopia.Methods. We retrospectively examined sixty-eight eyes of 37 consecutive patients who underwent conventional LASIK for the correction of myopia (−3.00 to −12.75 diopters (D)). At 3 months and 1, 4, 8, and 12 years postoperatively, we assessed the safety, efficacy, predictability, stability, mean keratometry, central corneal thickness, and adverse events.Results. The safety and efficacy indices were0.82±0.29and0.67±0.37, respectively, 12 years postoperatively. At 12 years, 53% and 75% of the eyes were within 0.5 and 1.0 D, respectively, of the targeted correction. Manifest refraction changes of −0.74±0.99 D occurred from 3 months to 12 years after LASIK (p<0.001). We found a significant correlation of refractive regression with the changes in keratometric readings from 3 months to 12 years postoperatively (Pearson correlation coefficient,r=-0.28,p=0.02), but not with the changes in central corneal thickness (r=-0.08,p=0.63). No vision-threatening complications occurred in any case.Conclusions. Conventional LASIK offered good safety outcomes during the 12-year observation period. However, the efficacy and the predictability gradually decreased with time owing to myopic regression in relation to corneal steepening.


2017 ◽  
Vol 27 (6) ◽  
pp. 686-693 ◽  
Author(s):  
Jorge L. Alió del Barrio ◽  
Mauro Tiveron ◽  
Ana B. Plaza-Puche ◽  
María A. Amesty ◽  
Laura Casanova ◽  
...  

Purpose To evaluate the visual outcomes after femtosecond laser-assisted laser in situ keratomileusis (LASIK) surgery to correct primary compound hyperopic astigmatism with high cylinder using a fast repetition rate excimer laser platform with optimized aspheric profiles and cyclotorsion control. Methods Eyes with primary simple or compound hyperopic astigmatism and a cylinder power ≥3.00 D had uneventful femtosecond laser-assisted LASIK with a fast repetition rate excimer laser ablation, aspheric profiles, and cyclotorsion control. Visual, refractive, and aberrometric results were evaluated at the 3- and 6-month follow-up. The astigmatic outcome was evaluated using the Alpins method and ASSORT software. Results This study enrolled 80 eyes at 3 months and 50 eyes at 6 months. The significant reduction in refractive sphere and cylinder 3 and 6 months postoperatively (p<0.01) was associated with an improved uncorrected distance visual acuity (p<0.01). A total of 23.75% required retreatment 3 months after surgery. Efficacy and safety indices at 6 months were 0.90 and 1.00, respectively. At 6 months, 80% of eyes had an SE within ±0.50 D and 96% within ±1.00 D. No significant differences were detected between the third and the sixth postoperative months in refractive parameters. A significant increase in the spherical aberration was detected, but not in coma. The correction index was 0.94 at 3 months. Conclusions Laser in situ keratomileusis for primary compound hyperopic astigmatism with high cylinder (>3.00 D) using the latest excimer platforms with cyclotorsion control, fast repetition rate, and optimized aspheric profiles is safe, moderately effective, and predictable.


2019 ◽  
Vol 30 (6) ◽  
pp. 1238-1245
Author(s):  
Ana B Plaza-Puche ◽  
Verónica Vargas ◽  
Pilar Yébana ◽  
Samuel Arba ◽  
Jorge L Alio

Purpose: The aim of this study is to analyze the long-term stability of the corneal topography, the functional optical zone, and the refractive stability throughout 3 years following laser in situ keratomileusis surgery for hyperopia using a 500-Hz excimer laser system. Methods: This retrospective consecutive observational case series study comprised 66 eyes that underwent laser in situ keratomileusis to correct hyperopia with a postoperative follow-up of 3 years. Laser in situ keratomileusis procedures were performed using the SCHWIND Amaris 500-Hz excimer laser. Main outcomes measured were stability of the functional optical zone at corneal topography and corneal aberrometry. Results: Statistically significant differences were found in simulated keratometry (K2 (steep meridian) and Km (mean keratometry)) between 3 and 36 months postoperatively ( p ⩽ 0.01); these differences disappeared at 12 and 36 months ( p ⩾ 0.18). No statistically significant changes were observed in the horizontal and vertical diameter of the functional optical zone throughout the whole follow-up ( p ⩾ 0.07). A statistically significant difference was found in the spherical aberration between 3 and 36 months ( p = 0.02); this difference disappeared when compared between 12 and 36 months ( p = 0.72). Statistically significant correlations were detected between the vertical functional optical zone and coma root mean square ( r = –0.510, p < 0.01) and between the vertical functional optical zone and spherical aberration ( r = 0.441, p = 0.02) 36 months after surgery. Conclusion: Following 3 years of hyperopic laser in situ keratomileusis with a 500-Hz Amaris excimer laser, keratometry, functional optical zone, and corneal aberrations remain stable from 1 year after surgery. Topographical regression is not observed in hyperopic laser in situ keratomileusis with this excimer laser technology from 1 year after surgery.


2008 ◽  
Vol 34 (9) ◽  
pp. 1527-1531 ◽  
Author(s):  
Takashi Miyai ◽  
Kazunori Miyata ◽  
Ryohei Nejima ◽  
Masato Honbo ◽  
Keiichiro Minami ◽  
...  

2012 ◽  
Vol 32 (5) ◽  
pp. 435-441 ◽  
Author(s):  
Faik Oruçoğlu ◽  
James D. Kingham ◽  
Mahir Kendüşim ◽  
Buket Ayoğlu ◽  
Berrin Toksu ◽  
...  

Cancers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 3864
Author(s):  
Maximilian Gassenmaier ◽  
Matthias Hahn ◽  
Gisela Metzler ◽  
Jürgen Bauer ◽  
Amir Sadegh Yazdi ◽  
...  

Background: PReferentially expressed Antigen in MElanoma (PRAME) immunohistochemistry is increasingly used as diagnostic adjunct in the evaluation of melanocytic tumors. The expression and prognostic significance of PRAME in melanomas ≤1.0 mm and its diagnostic utility in the distinction from severely dysplastic compound nevi (SDN) have not been studied. Methods: We investigated and compared the immunohistochemical PRAME expression in 70 matched thin metastasizing and non-metastasizing melanomas and 45 nevi from patients with long-term follow-up (35 SDN and 10 unequivocally benign compound nevi). Results: Diffuse PRAME staining in >75% of lesional epidermal and dermal melanocytes identified 58.6% of thin melanomas but did not distinguish metastasizing from non-metastasizing melanomas (p = 0.81). A superficial atypical melanocytic proliferation of uncertain significance, in which the final diagnostic interpretation favored a SDN was the only nevus with diffuse PRAME expression (1/45). Melanomas and SDN with PRAME immunoreactivity exhibited different staining patterns. Most melanomas (67.6%) showed uniform PRAME expression in the in situ and invasive component, whereas most SDN (81.0%) showed a decreasing gradient with depth. Conclusion: Diffuse intraepidermal and dermal PRAME staining is highly specific for melanomas in the distinction from SDN. PRAME expression is not a prognostic biomarker in melanomas ≤1.0 mm.


Sign in / Sign up

Export Citation Format

Share Document