scholarly journals Intervention with selution SLR™ Agent Balloon for Endovascular Latent Limus therapy for failing AV Fistulas (ISABELLA) Trial: Protocol for a pilot clinical study and pre-clinical results

2021 ◽  
pp. 112972982110208
Author(s):  
Tjun Yip Tang ◽  
Tze-Tec Chong ◽  
Charyl Jia Qi Yap ◽  
Shereen Xue Yun Soon ◽  
Sze Ling Chan ◽  
...  

Background: The aim of this pilot clinical study is to evaluate the safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-coated balloon (M.A. MedAlliance SA, Nyon, Switzerland) for improving the patency of failing arterio-venous fistulas (AVF) in hemodialysis patients. We also present herein a pre-clinical pharmacokinetic and safety evaluation of Selution™ to justify its first use in hemodialysis patients for endovascular access salvage. Methods and results: This is an investigator-initiated prospective single-center, non-blinded single-arm trial. Forty patients with clinically significant de novo or recurrent stenoses in a mature AVF circuit will be recruited. All stenotic lesions will be prepared with high pressure non-compliant conventional balloon angioplasty (CBA) prior to deployment of the Sustained-Release Selution™ sirolimus drug-eluting balloon. The primary efficacy endpoint is 6-month target lesion primary patency and the primary safety endpoint is freedom from localized or systemic serious adverse events through 30 days. Secondary endpoints of interest include technical and clinical success rates and circuit access patency at 3 and 6 months. Follow-up will occur for 2 years for those patients whose AVFs remain patent. Pharmacokinetic and histological animal safety studies performed with the Selution™ coating formulation showed prolonged arterial tissue retention of sirolimus with therapeutic levels up to 60 days and non-toxic and rapidly declining blood levels. Histological results in animal models demonstrated safety, freedom from intraluminal thrombus, reduction in restenosis by sirolimus elution compared to CBA, and no evidence of embolic phenomena indicative of adverse particulate effects. Discussion: Long release sirolimus coated balloons may serve as a promising novel alternative therapy to paclitaxel-based technology for treating conduit stenosis secondary to neointimal hyperplasia. Pre-clinical pharmacokinetic and histological animal data are encouraging and provide suggestion of safety and efficacy in this setting. This single-center trial will provide a first step toward demonstration of efficacy and safety of this device for treatment of stenotic fistulas.

Author(s):  
George Crossley ◽  
Prashanthan Sanders ◽  
Paolo De Filippo ◽  
Khaldoun Tarakji ◽  
Bert Hansky ◽  
...  

Background: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small diameter, lumenless, catheter delivered, defibrillator lead was developed with the aim to improve long term reliability. Methods and Results: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients will participate for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. Conclusion: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


2011 ◽  
Vol 6 (1) ◽  
pp. 39
Author(s):  

Background:Since the first reported use of percutaneous transluminal coronary angioplasty, advances in the interventional cardiology arena have been fast paced. Developers and clinicians are adapting from the learning curve awarded by the time-course of drug-eluting stent (DES) evolution. BioMime™ sirolimus-eluting stent (SES) is a step towards biomimicry. The stent is built on a strut of ultra-low thickness (65μm), a cobalt–chromium platform using an intelligent hybrid of closed and open cells allowing for morphology-mediated expansion. It employs a well-known antiproliferative – sirolimus – that elutes from a known biodegradable copolymer formulation within 30 days. The resultant stent demonstrates almost 100% endothelialisation at 30 days in preclinical models.Methods:The meriT-1 was a prospective, single-arm, single-centre trial to evaluate the safety and efficacy of BioMime SES in 30 patients with a single de novo lesion in native coronary arteries. The primary safety and efficacy end-points were major adverse cardiac events (MACE) at 30 days and in-stent late lumen loss at eight months, as measured using quantitative coronary angiographic (QCA) method. Secondary safety and efficacy end-points included MACE at one and two years and angiographic binary restenosis at eight-month angiographic follow-up. Other end-points included the occurrence of stent thrombosis at acute, subacute, late and very late periods and the percentage of diameter stenosis by QCA.Results:No MACE were observed and the median in-stent late luminal loss in 20 (67%) subjects studied by QCA was 0.15mm, with 0% binary restenosis at eight-month follow-up. No stent thrombosis was observed up to one-year follow-up.Conclusions:In comparison to currently available DES, BioMime SES appears to have a considerable scientific basis for prevention of neointimal proliferation, restenosis and associated clinical events.


2013 ◽  
Vol 24 (1) ◽  
pp. 14
Author(s):  
Ramprasad Ramalingam ◽  
Prabhakar Arunasalam ◽  
K. Sampath Kumar