Structural brain abnormalities are related to retinal nerve fiber layer thinning and disease duration in neuromyelitis optica spectrum disorders

2014 ◽  
Vol 20 (9) ◽  
pp. 1189-1197 ◽  
Author(s):  
Felipe von Glehn ◽  
Sven Jarius ◽  
Rodrigo Pessoa Cavalcanti Lira ◽  
Maria Carolina Alves Ferreira ◽  
Fadua H Ribeiro von Glehn ◽  
...  

Background: Although aquaporin-4 (AQP4) is widely expressed in the human brain cortex, lesions are rare in neuromyelitis optica (NMO) spectrum disorders (NMOSD). Recently, however, several studies have demonstrated occult structural brain atrophy in NMO. Objective: This study aims to investigate magnetic resonance imaging (MRI) patterns of gray matter (GM) and white matter (WM) abnormalities in patients with NMOSD and to assess the visual pathway integrity during disease duration correlation of the retinal nerve fiber layer (RNFL) and pericalcarine cortex thickness. Methods: Twenty-one patients with NMOSD and 34 matched healthy controls underwent both high-field MRI (3T) high-resolution T1-weighted and diffusion-tensor MRI. Voxel-based morphometry, cortical analyses (Freesurfer) and diffusion-tensor imaging (DTI) analyses (TBSS-FSL) were used to investigate brain abnormalities. In addition, RNFL measurement by optic-coherence tomography (OCT) was performed. Results: We demonstrate that NMOSD is associated with GM and WM atrophy, encompassing more frequently the motor, sensory and visual pathways, and that the extent of GM atrophy correlates with disease duration. Furthermore, we demonstrate for the first time a correlation between RNFL and pericalcarine cortical thickness, with cortical atrophy evolving over the course of disease. Conclusions: Our findings indicate a role for retrograde and anterograde neurodegeneration in GM atrophy in NMOSD. However, the presence atrophy encompassing almost all lobes suggests that additional pathomechanisms might also be involved.

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Guohong Tian ◽  
Zhenxin Li ◽  
Guixian Zhao ◽  
Chaoyi Feng ◽  
Mengwei Li ◽  
...  

We evaluate a cohort of optic neuritis and neuromyelitis optica (NMO) spectrum disorders patients in a territory hospital in China. The peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell complex (GCC) were measured using spectral-domain OCT after 6 months of acute onset. The results showed that both the peripapillary RNFL and macular GCC were significantly thinner in all optic neuritis subtypes compared to controls. In addition, the recurrent optic neuritis and NMO groups showed more severe damage on the RNFL and GCC pattern.


2009 ◽  
Vol 46 (5) ◽  
pp. 633 ◽  
Author(s):  
Rebecca I. Spain ◽  
Mitchell Maltenfort ◽  
Robert C. Sergott ◽  
Thomas P. Leist

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Alex P. Lange ◽  
Reza Sadjadi ◽  
Jameelah Saeedi ◽  
Janette Lindley ◽  
Fiona Costello ◽  
...  

Objective. The aim of this study was to compare retinal nerve fiber layer thickness (RNFLT) between spectral-domain (SD-) and time-domain optical coherence tomography (TD-OCT) in MS patients and healthy controls (HC). Furthermore, RNFLT between MS eyes with and without optic neuritis (ON) and HC should be explored. Finally, the relationship between RNFLT, disease duration, EDSS, and disease modifying therapy (DMT) should be established.Design. Prospective, cross-sectional study.Participants. 28 MS patients and 35 HC.Methods. Both groups underwent TD- and SD-OCT measurements. RFNLT was correlated between the two machines and between MS eyes with and without ON and HC. Furthermore, RNFLT was correlated to disease duration, EDSS and DMT.Results. A strong correlation (Pearson’sr=0.921,P<0.001), but a statistically significant difference of 2 μm (P<0.001), was found between the two devices. RNFLT was significantly different between MS eyes with history of ON (mean RFNLT (SD) 72.21 μm (15.83 μm)), MS eyes without history of ON 93.03 μm (14.25 μm), and HC 99.07 μm (7.23 μm) (P<0.001).Conclusions. The measurements between different generation of OCT machines are not interchangeable, which should be taken into account if comparing results between different machines and switching OCT machine in longitudinal studies.


Sign in / Sign up

Export Citation Format

Share Document