Evaluation of Aortic Zone 2 Proximal Landing Accuracy During Thoracic Endovascular Aortic Repair Following Carotid-Subclavian Revascularization

2021 ◽  
Vol 55 (4) ◽  
pp. 355-360
Author(s):  
Sally H. J. Choi ◽  
Gary K. Yang ◽  
Keith Baxter ◽  
Joel Gagnon

Background: Adequate seal for thoracic endovascular aortic repair (TEVAR) commonly requires landing in zone 2, but can prove to be challenging due to the tortuous and angulated anatomy of the region. Objectives: Our objective was to determine the proximal landing accuracy of zone 2-targeted TEVARs following carotid-subclavian revascularization (CSR) and its impact on clinical outcomes. Methods: Retrospective review of patients that underwent CSR for zone 2 endograft delivery at a tertiary institute between January 2008 and March 2018 was conducted. Technical outcomes were assessed by examining the incidence of intraoperative corrective maneuvers, 1a endoleaks and reinterventions. Distance to target and incidence of LSA stump filling were examined as radiographic markers of landing accuracy. Results: Zone 2-targeted TEVAR with CSR was performed in 53 patients for treatment of dissections (49%), aneurysms (30%) or trauma (21%). Nine (17%) cases required intraoperative corrective procedures: 5 (9%) proximal cuffs due to type 1a endoleak and 4 (8%) left common carotid artery (LCCA) stenting due to inadvertent coverage. Cases performed using higher resolution hybrid fluoroscopy machine compared to mobile C-arm were associated with increased proximal cuff use (OR 8.8; 95% CI 1.2-62.4). Average distance between the proximal edge of the covered graft to LCCA was 8 ± 1 mm and larger distances were not associated with higher rates of 1a endoleak. Twenty-eight (53%) cases of antegrade LSA stump filling were noted on follow-up imaging, but were not associated with higher rates of reinterventions (OR 0.8, 95% CI [0.2-4.6]). Three (6%) patients had a stroke within 30 days and 4 (8%) patients expired within 1 month. Intraoperative corrective maneuvers, post-operative 1a endoleak and reinterventions were not associated with higher rates of stroke or mortality. Conclusion: Using current endografts and imaging modalities, zone 2-targeted TEVARs have suboptimal technical accuracy.

2018 ◽  
Vol 52 (3) ◽  
pp. 173-180 ◽  
Author(s):  
Brant W. Ullery ◽  
Ga-Young Suh ◽  
Kelsey Hirotsu ◽  
David Zhu ◽  
Jason T. Lee ◽  
...  

Objective: To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Methods: Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. Results: The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P < .005) and lower than both the left subclavian and brachiocephalic branch angles postintervention ( P < .05). From pre- to postoperative, no significant change in branch angle was found in any of the great vessels. Maximum curvature change of the stented lumen from pre- to postprocedure was greater than those of the ascending aorta and aortic arch ( P < .05). Conclusion: Thoracic endovascular aortic repair results in relative straightening of the stented aortic region and also accentuates the native curvature of the ascending aorta when the endograft has a more proximal landing zone. Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.


2020 ◽  
Vol 27 (5) ◽  
pp. 801-804
Author(s):  
Catharina Gronert ◽  
Nikolaos Tsilimparis ◽  
Giuseppe Panuccio ◽  
Ahmed Eleshra ◽  
Fiona Rohlffs ◽  
...  

Purpose: To report a case of chronic intermittent spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR) and its successful treatment using hypogastric artery stenting. Case Report: A 79-year-old patient presented in May 2013 with a thoracic aortic aneurysm (TAA) and a contained rupture. He urgently underwent TEVAR that covered 274 mm of descending thoracic aorta without immediate postoperative signs of acute SCI. At 3-month follow-up, he reported repeating incidents of sudden lower extremity weakness leading to a fall with a humerus fracture. A neurological consultation revealed the tentative diagnosis of intermittent SCI caused by TEVAR and initially recommended a conservative approach. During the following year there was no clinical improvement of the symptoms. Computed tomography angiography showed a high-grade stenosis of the right hypogastric artery, which was stented in November 2014 to improve the collateral network of spinal cord perfusion. Following treatment, the patient had no further neurological symptoms; at 32 months after the reintervention, the imaging follow-up documented a patent stent and continued exclusion of the TAA. Conclusion: Intermittent neurological symptoms after TEVAR should be suspected as chronic intermittent SCI. The improvement of collateral networks of the spinal cord by revascularization of the hypogastric artery is a viable treatment option.


2019 ◽  
Vol 56 (3) ◽  
pp. 587-594 ◽  
Author(s):  
Huey-Shiuan Kuo ◽  
Jih-Hsin Huang ◽  
Jer-Shen Chen

Abstract OBJECTIVES This study aimed to evaluate the efficacy and safety of a handmade fenestrated stent graft over an aortic stent graft for preserving the left subclavian artery (LSA) in thoracic endovascular aortic repair (TEVAR). METHODS From July 2015 to October 2018, a total of 32 consecutive patients with various thoracic aortic pathologies who underwent TEVAR in which handmade fenestration over a thoracic aortic stent graft was used for LSA were included. Outcomes including technical success, procedure-related complications, perioperative mortality and morbidity and graft patency were analysed. RESULTS Twenty-four patients (75.00%) presented with aortic dissection, 5 patients (15.63%) with thoracic aortic aneurysm and 2 patients (6.25%) with penetrating aortic ulcer; 1 patient (3.13%) required re-TEVAR due to endoleak and sac expansion from previous TEVAR for thoraco-abdominal aneurysm. TEVAR was performed in a zone 2 landing with single fenestration for LSA (26 patients, 81.25%), zone 1 landing with double fenestration for both LSA and left common carotid artery (5 patients, 15.63%) or zone 1 landing with single fenestration for LSA and a chimney graft for left common carotid artery (1 patient, 3.13%). The technical success rate, defined as the successful alignment of fenestration to LSA, was 93.75%. At a mean follow-up of 17.3 months, 4 cases of endoleak and 2 cases of stent graft-induced new entry were noted, 3 of which were treated endovascularly. CONCLUSIONS Our preliminary results demonstrate the viability of preserving LSA blood flow in TEVAR using a handmade stent graft fenestration to treat various aortic pathologies in various clinical situations and the technical feasibility and short-term results that may justify the use of this method in emergency cases.


2020 ◽  
Vol 54 (8) ◽  
pp. 676-680
Author(s):  
Khalil Qato ◽  
Allan Conway ◽  
Eileen Lu ◽  
Nhan Nguyen Tran ◽  
Gary Giangola ◽  
...  

Objectives: Thoracic endovascular aortic repair (TEVAR) remains controversial in patients with connective tissue disorders given the concern for durability. We report on the largest series to date on outcomes of patients with thoracic aortic disease and connective tissue disorders treated with TEVAR. Methods: The Vascular Quality Initiative registry identified 12 207 patients treated with TEVAR from January 2010 to December 2018, including 102 with Marfans, Ehlers-Danlos, or Loey-Dietz syndrome. Outcomes were analyzed per the Society for Vascular Surgery reporting standards. Results: Median age was 50.6 years (interquartile range: 57.0-75.0), and 62 (60.7%) were male. Eighty-eight (86.3%) patients had Marfan, 9 (8.8%) had Ehlers-Danlos, and 5 (4.9%) had Loey-Dietz syndrome. Twenty-six (25.5%) patients were treated for degenerative aneurysmal disease and 76 (74.5%) patients for type B dissections (33 acute, 31 chronic). Most common indications for interventions in patients with type B dissection were pain (n = 41), aneurysmal degeneration (n = 16), and malperfusion (n = 8), with 3 patients who presented ruptured. There was no significant difference in perioperative complications between acute/chronic dissections and aneurysms ( P = .14). Percutaneous access was utilized in 61.7% of patients, with a 2.9% rate of arterial injury requiring reintervention. Follow-up data were available for 75 (73.3%) patients at a mean follow-up of 15.6 months. Overall mortality was 5.3%. There were 30 patients with follow-up endoleak data, and 8 (26.7%) endoleaks were identified. All endoleaks were in patients treated for acute type B dissection, and all resolved after a mean of 2.1 reinterventions. Three patients treated for acute Type B Aortic Dissection (TBAD) had retrograde dissections requiring intervention. Discussion: Thoracic endovascular aortic repair for patients with connective tissue disorders can be performed with low perioperative mortality, spinal cord ischemia, or Cerebrovascular Accident (CVA). On follow-up, acute type B aortic dissections represent a higher risk subgroup with increased rates of endoleak and retrograde dissection. Closer follow-up for these patients and early reintervention may be beneficial.


2020 ◽  
Vol 31 (3) ◽  
pp. 346-353
Author(s):  
Yaojun Dun ◽  
Yi Shi ◽  
Hongwei Guo ◽  
Yanxiang Liu ◽  
Xiangyang Qian ◽  
...  

Abstract OBJECTIVES Our goal was to investigate the surgical strategy for type Ia endoleak after thoracic endovascular aortic repair (TEVAR) by reporting our experiences. METHODS From November 2012 to September 2019, a total of 23 patients received surgical management for type Ia endoleak after TEVAR. RESULTS The operations included total arch replacement with the frozen elephant trunk technique in 15 patients, direct closure of the endoleak in 2 patients, hybrid aortic arch repair in 4 patients, arch debranching with TEVAR in 1 patient and left common carotid artery to left subclavian artery bypass with TEVAR in 1 patient. Among 21 patients with cardiopulmonary bypass (CPB), the mean CPB and aortic cross-clamp times were 146.7 ± 42.2 and 81.0 ± 43.3 min, respectively. The selective cerebral perfusion time was 18.8 ± 8.2 min in 17 patients with hypothermic circulatory arrest. The in-hospital mortality was 8.7% (2/23). Type Ia endoleak was sealed successfully after surgery in 95.5% (21/22) of patients. The follow-up data were available for all 21 survivors. The median follow-up period was 18 months (range 1–84 months). During the follow-up period, a total of 8 patients died or had aortic events, including 5 deaths and 6 aortic events. CONCLUSIONS Different surgical strategies could be selected to treat patients with type Ia endoleak after TEVAR, with acceptable early and late outcomes.


2018 ◽  
Vol 25 (5) ◽  
pp. 571-577 ◽  
Author(s):  
Claudia Menichini ◽  
Selene Pirola ◽  
Baolei Guo ◽  
Weiguo Fu ◽  
Zhihui Dong ◽  
...  

Purpose: To explore the potential role of morphological factors and wall stress in the formation of stent-graft–induced new entries (SINE) based on computed tomography (CT) images after thoracic endovascular aortic repair (TEVAR). Case Report: Two female patients aged 59 years (patient 1) and 44 years (patient 2) underwent TEVAR for type B dissection in the chronic (patient 1) or subacute (patient 2) phase. CT scans at 3-month follow-up showed varying degrees of false lumen thrombosis in both patients. At 14-month follow-up, a SINE was observed in patient 1 while the dissected aorta in the other patient remained stable. Morphological and finite element analyses were performed based on the first follow-up CT images. The computational results showed that the SINE patient had higher stent-graft tortuosity than the non-SINE patient and much higher wall stress in the region close to the distal SINE. Conclusion: This case study suggests that high stent-graft tortuosity can lead to high wall stress, which is potentially linked to the formation of SINE. Further large population-based studies are needed to confirm this preliminary finding.


Sign in / Sign up

Export Citation Format

Share Document