An avulsed radial artery with a high take-off

Vascular ◽  
2014 ◽  
Vol 23 (2) ◽  
pp. 197-200 ◽  
Author(s):  
Geurys Rojas-Marte ◽  
On Chen ◽  
Shivani Verma ◽  
Atul Rao ◽  
Jacob Shani ◽  
...  

A 63-year-old female was diagnosed with severe aortic stenosis, who underwent a diagnostic coronary angiography via transradial approach prior an aortic-valve replacement. After imaging the left coronary system, entrapment of the diagnostic catheter was encountered as a result of spasm of the radial artery. An arteriogram of the arm revealed an anatomical variation in the radial artery (high take-off). Several attempts to remove the entrapped catheter resulted in avulsion of the artery, which was managed successfully with coil embolization. To our knowledge, no such complication has been reported.

2014 ◽  
Vol 2014 ◽  
pp. 1-3
Author(s):  
N. J. W. Verouden ◽  
F. Kiemeneij

Spasm of the radial artery is the most important cause of failure to perform coronary angiography via the transradial approach. Spasmolytic cocktail may prevent radial artery spasm but is relatively contraindicated in patients with aortic stenosis or diminished left ventricular function. In this case report we describe a recently published technique to overcome severe radial spasm during transradial coronary angiography in a patient with moderate aortic valve stenosis.


2012 ◽  
Vol 15 (4) ◽  
pp. 182
Author(s):  
Fotios A. Mitropoulos ◽  
Meletios A. Kanakis ◽  
Sotiria C. Apostolopoulou ◽  
Spyridon Rammos ◽  
Constantine E. Anagnostopoulos

<p>Mechanical and biological prostheses are valid options when aortic valve replacement is necessary. The Ross procedure is also an alternative solution, especially for young patients.</p><p>We describe the case of a young patient with congenital aortic stenosis and bicuspid aortic valve who presented with dyspnea on exertion. An open commissurotomy was performed, and within 8 months the patient developed recurrent symptoms of severe aortic stenosis. He underwent redo sternotomy and a Ross-Konno procedure with an uneventful recovery.</p>


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Piayda ◽  
A Wimmer ◽  
H Sievert ◽  
K Hellhammer ◽  
S Afzal ◽  
...  

Abstract Background In the era of transcatheter aortic valve replacement (TAVR), there is renewed interest in percutaneous balloon aortic valvuloplasty (BAV), which may qualify as the primary treatment option of choice in special clinical situations. Success of BAV is commonly defined as a significant mean pressure gradient reduction after the procedure. Purpose To evaluate the correlation of the mean pressure gradient reduction and increase in the aortic valve area (AVA) in different flow and gradient patterns of severe aortic stenosis (AS). Methods Consecutive patients from 01/2010 to 03/2018 undergoing BAV were divided into normal-flow high-gradient (NFHG), low-flow low-gradient (LFLG) and paradoxical low-flow low-gradient (pLFLG) AS. Baseline characteristics, hemodynamic and clinical information were collected and compared. Additionally, the clinical pathway of patients (BAV as a stand-alone procedure or BAV as a bridge to aortic valve replacement) was followed-up. Results One-hundred-fifty-six patients were grouped into NFHG (n=68, 43.5%), LFLG (n=68, 43.5%) and pLFLG (n=20, 12.8%) AS. Underlying reasons for BAV and not TAVR/SAVR as the primary treatment option are displayed in Figure 1. Spearman correlation revealed that the mean pressure gradient reduction had a moderate correlation with the increase in the AVA in patients with NFHG AS (r: 0.529, p&lt;0.001) but showed no association in patients with LFLG (r: 0.145, p=0.239) and pLFLG (r: 0.030, p=0.889) AS. Underlying reasons for patients to undergo BAV and not TAVR/SAVR varied between groups, however cardiogenic shock or refractory heart failure (overall 46.8%) were the most common ones. After the procedure, independent of the hemodynamic AS entity, patients showed a functional improvement, represented by substantially lower NYHA class levels (p&lt;0.001), lower NT-pro BNP levels (p=0.003) and a numerical but non-significant improvement in other echocardiographic parameters like the left ventricular ejection fraction (p=0.163) and tricuspid annular plane systolic excursion (TAPSE, p=0.066). An unplanned cardiac re-admission due to heart failure was necessary in 23.7% patients. Less than half of the patients (44.2%) received BAV as a bridge to TAVR/SAVR (median time to bridge 64 days). Survival was significantly increased in patients having BAV as a staged procedure (log-rank p&lt;0.001). Conclusion In daily clinical practice, the mean pressure gradient reduction might be an adequate surrogate of BAV success in patients with NFHG AS but is not suitable for patients with other hemodynamic entities of AS. In those patients, TTE should be directly performed in the catheter laboratory to correctly assess the increase of the AVA. BAV as a staged procedure in selected clinical scenarios increases survival and is a considerable option in all flow states of severe AS. (NCT04053192) Figure 1 Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charbel Abi Khalil ◽  
Barbara Ignatiuk ◽  
Guliz Erdem ◽  
Hiam Chemaitelly ◽  
Fabio Barilli ◽  
...  

AbstractTranscatheter aortic valve replacement (TAVR) has shown to reduce mortality compared to surgical aortic valve replacement (sAVR). However, it is unknown which procedure is associated with better post-procedural valvular function. We conducted a meta-analysis of randomized clinical trials that compared TAVR to sAVR for at least 2 years. The primary outcome was post-procedural patient-prosthesis-mismatch (PPM). Secondary outcomes were post-procedural and 2-year: effective orifice area (EOA), paravalvular gradient (PVG) and moderate/severe paravalvular leak (PVL). We identified 6 trials with a total of 7022 participants with severe aortic stenosis. TAVR was associated with 37% (95% CI [0.51–0.78) mean RR reduction of post-procedural PPM, a decrease that was not affected by the surgical risk at inclusion, neither by the transcatheter heart valve system. Postprocedural changes in gradient and EOA were also in favor of TAVR as there was a pooled mean difference decrease of 0.56 (95% CI [0.73–0.38]) in gradient and an increase of 0.47 (95% CI [0.38–0.56]) in EOA. Additionally, self-expandable valves were associated with a higher decrease in gradient than balloon ones (beta = 0.38; 95% CI [0.12–0.64]). However, TAVR was associated with a higher risk of moderate/severe PVL (pooled RR: 9.54, 95% CI [5.53–16.46]). All results were sustainable at 2 years.


Sign in / Sign up

Export Citation Format

Share Document