Experimental and theoretical study on hygrothermal long-term performance of outer assemblies in lightweight passive house

2017 ◽  
Vol 41 (4) ◽  
pp. 299-320 ◽  
Author(s):  
Jan Radon ◽  
Krzysztof Was ◽  
Agnieszka Flaga-Maryanczyk ◽  
Jacek Schnotale

The article presents results of long-term experimental study of hygrothermal performance of envelope assemblies in a passive house located in Boruszowice (Southern Poland). The building was constructed in 2010 using prefabricated, lightweight technology. The construction of the walls and roof had been carefully planned to test both traditional solutions with higher thermal insulation and modified ones to improve the hygrothermal performance. Altogether, eight different walls and two roof constructions were integrated into the building structure and tested from the beginning of 2011 to the end of 2015 under real climate and usage conditions. In all assemblies, temperature was measured in three and relative humidity in four points at the surface and inside. Inner climate was measured by thermohygrometers installed in the rooms and outer climate was recorded by a weather station located near the building. Theoretical calculations were made using WUFI® Plus software. Based on experimental and calculation results, the main hygrothermal phenomena depending on construction specifics and used materials are presented.

2021 ◽  
pp. 174425912110171
Author(s):  
Hideya Yamamoto ◽  
Daisuke Ogura

Vacuum insulation panels (VIPs) with a glass-fiber core has been considered to be difficult to operate for a long period of time, such as for building applications, because the thermal conductivity rises rapidly as the pressure increases. However, glass-fiber-core VIPs contain a material called a getter that continuously adsorbs permeated gas, and a theoretical model that considers the properties of the getter has not yet been developed. In this paper, the gas-adsorption mechanism by getters was investigated and a long-term-performance prediction model that considers the temperature dependence was proposed. Some gases were not adsorbed by the getter in the VIPs; however, a model was proposed that takes into account the non-absorbed gases by applying partial pressure to the adsorption isotherm in advance. The long-term performance of VIPs with different areas and volumes was compared with the measured values, and the validity of the calculation results was confirmed. These results show that the long-term performance of VIPs of different sizes can be accurately predicted when the getter performance is well understood.


2020 ◽  
Vol 14 (1) ◽  
Author(s):  
Wolfgang Hasper ◽  
Thomas Kirtschig ◽  
Mark Siddall ◽  
David Johnston ◽  
Gernot Vallentin ◽  
...  

Author(s):  
Carl Malings ◽  
Rebecca Tanzer ◽  
Aliaksei Hauryliuk ◽  
Provat K. Saha ◽  
Allen L. Robinson ◽  
...  

2008 ◽  
Vol 56 (S 1) ◽  
Author(s):  
CC Badiu ◽  
W Eichinger ◽  
D Ruzicka ◽  
I Hettich ◽  
S Bleiziffer ◽  
...  