scholarly journals Lateral Extra-Articular Tenodesis Reduces ACL Graft Force Under Multiplanar Torques Simulationg Pivot Shit

2020 ◽  
Vol 8 (7_suppl6) ◽  
pp. 2325967120S0035
Author(s):  
Niv Marom ◽  
Herve Ouanezar ◽  
hamidreza jahandar ◽  
Zaid Zayyad ◽  
Thomas Fraychineaud ◽  
...  

Objectives: Utilization of lateral extra-articular tenodesis (LET) in conjunction with anterior cruciate ligament reconstruction (ACLR) has increased in recent years, however, the biomechanical impact of LET, when performed with contemporary techniques, on both load sharing between the ACL graft and the LET and on knee kinematics is not completely clear. The purpose of this study was to quantify the effect of LET performed with ACLR, in the presence of a compromised anterolateral tissues, on (1) forces carried by the ACL graft and the LET and (2) knee kinematics, during simulated pivot shift. Methods: manipulator equipped with a six-axis force-torque sensor. The robot applied multiplanar torques simulating two types of pivot shift (PS) subluxing the lateral compartment at 15° and 30° of knee flexion. The following loading combinations were applied: (PS1) 8 Nm of valgus and 4 Nm of internal rotation torques; (PS2) 100 N compression force, 8 Nm valgus torque, 2 Nm internal rotation torque, and 30 N anterior force. Anteroposterior (AP) translation in the lateral compartment of the knee was recorded in the following states: ACL intact, sectioned, reconstructed and, finally, after sectioning the anterolateral ligament (ALL) and kaplan fibers and performing a LET. ACLR was performed utilizing a bone-patellar tendon-bone autograft, via medial parapatellar arthrotomy. LET was performed using a modified lemaire technique with a metal staple femoral fixation at 60° of flexion in neutral rotation. Resultant forces carried by the ACL graft and LET at the peak applied load in all tested conditions were determined utilizing the principle of superposition and serial sectioning. Results: Under both simulated pivot shift types and at both flexion angles the ACL force decreased with the addition of a LET, with the least force reduction of 39% for PS2 at 15° (p=0.01) and the most force reduction of 80% for PS1 at 30° (p<0.001). While decreasing ACL force, the LET carried at least 43% of the force carried by the ACL graft when tested without LET for PS2 at 15° and 91% of the force carried by the ACL graft at most, for PS1 at 30° (Table 1). For both combinations of multiplananr torques and at both flexion angles, the anterior tibial translation in the lateral compartment decreased for the ACLR+LET knee compared to the intact knee (5.3mm and 7.6mm decrease, for PS1 15° and 30° respectively, p<0.001; 4.4mm p=0.005 and 7.6mm p<0.001, for PS2 15° and 30°, respectively). (Figure 2). Conclusion: During a simulated pivot shift, LET shields the ACL graft from loading. This effect was greatest at 30° of flexion with an 80% drop in ACL graft force. While some shielding of load from the ACL graft can be beneficial, a more significant reduction in the load of the ACL graft may potentially be detrimental to the graft remodeling, maturation and function. The optimal load sharing pattern for improved clinical outcomes is not well understood and merit further investigation. In addition, LET also decreases anterior tibial translation in the lateral compartment to less than that of the intact knee, which represents overconstraint of the lateral compartment. These findings may support the purported “protective” effect of LET on the ACL graft and its important role in stabilizing the lateral compartment in the setting of combined ACL and anterolateral structures deficiency. The influence of overconstraint of the lateral compartment with LET warrants further biomechanical and clinical evaluation. [Table: see text][Figure: see text][Figure: see text]

2001 ◽  
Vol 29 (6) ◽  
pp. 771-776 ◽  
Author(s):  
Jürgen Höher ◽  
Akihiro Kanamori ◽  
Jennifer Zeminski ◽  
Freddie H. Fu ◽  
Savio L-Y. Woo

Ten cadaveric knees (donor ages, 36 to 66 years) were tested at full extension, 15°, 30°, and 90° of flexion under a 134-N anterior tibial load. In each knee, the kinematics as well as in situ force in the graft were compared when the graft was fixed with the tibia in four different positions: full knee extension while the surgeon applied a posterior tibial load (Position 1), 30° of flexion with the tibia at the neutral position of the intact knee (Position 2), 30° of flexion with a 67-N posterior tibial load (Position 3), and 30° of flexion with a 134-N posterior tibial load (Position 4). For Positions 1 and 2, the anterior tibial translation and the in situ forces were up to 60% greater and 36% smaller, respectively, than that of the intact knee. For Position 3, knee kinematics and in situ forces were closest to those observed in the intact knee. For Position 4, anterior tibial translation was significantly decreased by up to 2 mm and the in situ force increased up to 31 N. These results suggest that the position of the tibia during graft fixation is an important consideration for the biomechanical performance of an anterior cruciate ligament-reconstructed knee.


2019 ◽  
Vol 47 (6) ◽  
pp. 1376-1384 ◽  
Author(s):  
Frank R. Noyes ◽  
Lauren E. Huser ◽  
Brad Ashman ◽  
Michael Palmer

Background: Anterior cruciate ligament (ACL) graft conditioning protocols to decrease postoperative increases in anterior tibial translation and pivot-shift instability have not been established. Purpose: To determine what ACL graft conditioning protocols should be performed at surgery to decrease postoperative graft elongation after ACL reconstruction. Study Design: Controlled laboratory study. Methods: A 6 degrees of freedom robotic simulator evaluated 3 ACL graft constructs in 7 cadaver knees for a total of 19 graft specimens. Knees were tested before and after ACL sectioning and after ACL graft conditioning protocols before reconstruction. The ACL grafts consisted of a 6-strand semitendinosus-gracilis TightRope, bone–patellar tendon–bone TightRope, and bone–patellar tendon–bone with interference screws. Two graft conditioning protocols were used: (1) graft board tensioning (20 minutes, 80 N) and (2) cyclic conditioning (5°-120° of flexion, 90-N anterior tibial load) after graft reconstruction to determine the number of cycles needed to obtain a steady state with no graft elongation. After conditioning, the grafts were cycled a second time under anterior-posterior loading (100 N, 25° of flexion) and under pivot-shift loading (100 N anterior, 5-N·m internal rotation, 7 N·m valgus) to verify that the ACL flexion-extension conditioning protocol was effective. Results: Graft board tensioning did not produce a steady-state graft. Major increases in anterior tibial translation occurred in the flexion-extension graft-loading protocol at 25° of flexion (mean ± SD: semitendinosus-gracilis TightRope, 3.4 ± 1.1 mm; bone–patellar tendon–bone TightRope, 3.2 ± 1.0 mm; bone–patellar tendon–bone with interference screws, 2.4 ± 1.5 mm). The second method of graft conditioning (40 cycles, 5°-120° of flexion, 90-N anterior load) produced a stable conditioned state for all grafts, as the anterior translations of the anterior-posterior and pivot-shift cycles were statistically equivalent ( P < .05, 1-20 cycles). Conclusion: ACL graft board conditioning protocols are not effective, leading to deleterious ACL graft elongations after reconstruction. A secondary ACL graft conditioning protocol of 40 flexion-extension cycles under 90-N graft loading was required for a well-conditioned graft, preventing further elongation and restoring normal anterior-posterior and pivot-shift translations. Clinical Relevance: There is a combined need for graft board tensioning and robust cyclic ACL graft loading before final graft fixation to restore knee stability.


2020 ◽  
Vol 48 (13) ◽  
pp. 3183-3193
Author(s):  
Niv Marom ◽  
Hervé Ouanezar ◽  
Hamidreza Jahandar ◽  
Zaid A. Zayyad ◽  
Thomas Fraychineaud ◽  
...  

Background: The biomechanical effect of lateral extra-articular tenodesis (LET) performed in conjunction with anterior cruciate ligament (ACL) reconstruction (ACLR) on load sharing between the ACL graft and the LET and on knee kinematics is not clear. Purpose/Hypothesis: The purpose was to quantify the effect of LET on (1) forces carried by both the ACL graft and the LET and (2) tibiofemoral kinematics in response to simulated pivot shift and anterior laxity tests. We hypothesized that LET would decrease forces carried by the ACL graft and anterior tibial translation (ATT) in response to simulated pivoting maneuvers and during simulated tests of anterior laxity. Study Design: Controlled laboratory study. Methods: Seven cadaveric knees (mean age, 39 ± 12 years [range, 28-54 years]; 4 male) were mounted to a robotic manipulator. The robot simulated clinical pivoting maneuvers and tests of anterior laxity: namely, the Lachman and anterior drawer tests. Each knee was assessed in the following states: ACL intact, ACL sectioned, ACL reconstructed (using a bone–patellar tendon–bone autograft), and after performing LET (the modified Lemaire technique after sectioning of the anterolateral ligament and Kaplan fibers). Resultant forces carried by the ACL graft and LET at the peak applied loads were determined via superposition. ATT was determined in response to the applied loads. Results: With the applied pivoting loads, performing LET decreased ACL graft force up to 80% (44 ± 12 N; P < .001) and decreased ATT of the lateral compartment compared with that of the intact knee up to 7.6 ± 2.9 mm ( P < .001). The LET carried up to 91% of the force generated in the ACL graft during isolated ACLR (without LET). For simulated tests of anterior laxity, performing LET decreased ACL graft force by 70% (40 ± 20 N; P = .001) for the anterior drawer test with no significant difference detected for the Lachman test. No differences in ATT were deteced between ACLR with LET and the intact knee on both the Lachman and the anterior drawer tests ( P = .409). LET reduced ATT compared with isolated ACLR on the simulated anterior drawer test by 2.4 ± 1.8 mm ( P = .032) but not on the simulated Lachman test. Conclusion: In a cadaveric model, LET in combination with ACLR transferred loads from the ACL graft to the LET and reduced ATT with applied pivoting loads and during the simulated anterior drawer test. The effect of LET on ACL graft force and ATT was less pronounced on the simulated Lachman test. Clinical Relevance: LET in addition to ACLR may be a suitable option to offload the ACL graft and to reduce ATT in the lateral compartment to magnitudes less than that of the intact knee with clinical pivoting maneuvers. In contrast, LET did not offload the ACL graft or add to the anterior restraint provided by the ACL graft during the Lachman test.


2018 ◽  
Vol 46 (10) ◽  
pp. 2422-2431 ◽  
Author(s):  
Nicholas N. DePhillipo ◽  
Gilbert Moatshe ◽  
Alex Brady ◽  
Jorge Chahla ◽  
Zachary S. Aman ◽  
...  

Background: Ramp lesions were initially defined as a tear of the peripheral attachment of the posterior horn of the medial meniscus at the meniscocapsular junction. The separate biomechanical roles of the meniscocapsular and meniscotibial attachments of the posterior medial meniscus have not been fully delineated. Purpose: To evaluate the biomechanical effects of meniscocapsular and meniscotibial lesions of the posterior medial meniscus in anterior cruciate ligament (ACL)–deficient and ACL-reconstructed knees and the effect of repair of ramp lesions. Study Design: Controlled laboratory study. Methods: Twelve matched pairs of human cadaveric knees were evaluated with a 6 degrees of freedom robotic system. All knees were subjected to an 88-N anterior tibial load, internal and external rotation torques of 5 N·m, and a simulated pivot-shift test of 10-N valgus force coupled with 5-N·m internal rotation. The paired knees were randomized to the cutting of either the meniscocapsular or the meniscotibial attachments after ACL reconstruction (ACLR). Eight comparisons of interest were chosen before data analysis was conducted. Data from the intact state were compared with data from the subsequent states. The following states were tested: intact (n = 24), ACL deficient (n = 24), ACL deficient with a meniscocapsular lesion (n = 12), ACL deficient with a meniscotibial lesion (n = 12), ACL deficient with both meniscocapsular and meniscotibial lesions (n = 24), ACLR with both meniscocapsular and meniscotibial lesions (n = 16), and ACLR with repair of both meniscocapsular and meniscotibial lesions (n = 16). All states were compared with the previous states. For the repair and reconstruction states, only the specimens that underwent repair were compared with their intact and sectioned states, thus excluding the specimens that did not undergo repair. Results: Cutting the meniscocapsular and meniscotibial attachments of the posterior horn of the medial meniscus significantly increased anterior tibial translation in ACL-deficient knees at 30° ( P ≤ .020) and 90° ( P < .005). Cutting both the meniscocapsular and meniscotibial attachments increased tibial internal (all P > .004) and external (all P < .001) rotation at all flexion angles in ACL-reconstructed knees. Reconstruction of the ACL in the presence of meniscocapsular and meniscotibial tears restored anterior tibial translation ( P > .053) but did not restore internal rotation ( P < .002), external rotation ( P < .002), and the pivot shift ( P < .05). To restore the pivot shift, an ACLR and a concurrent repair of the meniscocapsular and meniscotibial lesions were both necessary. Repairing the meniscocapsular and meniscotibial lesions after ACLR did not restore internal rotation and external rotation at angles >30°. Conclusion: Meniscocapsular and meniscotibial lesions of the posterior horn of the medial meniscus increased knee anterior tibial translation, internal and external rotation, and the pivot shift in ACL-deficient knees. The pivot shift was not restored with an isolated ACLR but was restored when performed concomitantly with a meniscocapsular and meniscotibial repair. However, the effect of this change was minimal; although statistical significance was found, the overall clinical significance remains unclear. The ramp lesion repair used in this study failed to restore internal rotation and external rotation at higher knee flexion angles. Further studies should examine improved meniscus repair techniques for root tears combined with ACLRs. Clinical Relevance: Meniscal ramp lesions should be repaired at the time of ACLR to avoid continued knee instability (anterior tibial translation) and to eliminate the pivot-shift phenomenon.


2019 ◽  
Vol 7 (6_suppl4) ◽  
pp. 2325967119S0021
Author(s):  
Florian B. Imhoff ◽  
Julian Mehl ◽  
Elifho Obopilwe ◽  
Andreas Imhoff ◽  
Knut Beitzel

Aims and Objectives: To perform an anterior closing wedge osteotomy by 10° for slope reduction and investigate the effect of axial load and anterior drawer on forces on ACL graft, strain and femoro-tibial kinematics in a native, ACL-deficient and reconstructed knee. Materials and Methods: Ten cadaveric knees with an increased native slope were selected for this study based on CT meas-urements. An anterior closing-wedge osteotomy was performed by 10° and fixed with an external fixator. Tibial axial load (200 N, 400 N) was applied, while the tibial side was mounted on a free mov-ing X-Y-table with open rotation in 30° of knee flexion. Additionally, an anterior drawer (134 N) was performed with and without axial load (200 N). Specimens underwent native testing, cut ACL, and reconstructed ACL with a standardized quadruple semi-t/gracilis-allograft. Each condition was ran-domly tested with native slope and reduced slope. Change of forces on ACL-graft (attached load-cell) and strain on native ACL (via DVRT) were recorded. Throughout testing, 3D motion tracking captured anterior tibial translation (ATT) and rotation versus the fixed femur. Results: Preoperative, specimens showed an averaged lateral and medial slope of (average ±SD) 10° ± 1.4°, and age 48.2 ± 5.8years. Slope reduction significantly decreased forces on ACL graft by 17% (p=0.001) at 200 N and by 33% (p=0.0001) at 400 N of axial load. Furthermore, ATT was significantly decreased after slope reduc-tion in native (p=0.01), cut (p=0.005), and ACL-graft (p=0.01) status. Strain in native ACL de-creased by 9.7 ± 0.13% (p<0.0001) after slope reduction without any load. However, anterior drawer without axial load maintained significantly higher anterior tibial translation (native-pre 4.12 ± 0.65 mm vs. native-post 5.82 ± 1.51 mm, cut-ACL-pre 9.35 ± 1.57 mm vs cut-ACL-post 12.0 ± 3.53 mm, ACL-recon-pre 4.60 ± 0.97 mm vs. ACL-recon-post 5.73 ± 1.45 mm) and significantly higher forces on ACL graft (p=0.0006) after osteotomy. When axial load was combined with anterior drawer no significant change on ATT after osteotomy was observed. Rotational analysis did show a significant effect in the ACL cut condition due to slope correction. Overall, native and reconstruct-ed ACL showed the same tibial kinematics throughout testing. Conclusion: In general, osteotomy lowered ACL graft force and ACL strain when the joint was axially loaded. Anterior tibial translation was reduced even in an ACL deficient knee. When anterior drawer was performed without axial load, ATT was higher after slope reduction in every condition.


2005 ◽  
Vol 33 (6) ◽  
pp. 856-863 ◽  
Author(s):  
Robert H.P. Kilger ◽  
Maribeth Thomas ◽  
Scott Hanford ◽  
Dimosthenis A. Alaseirlis ◽  
Hans H. Paessler ◽  
...  

Background A variety of fixation devices are used for anterior cruciate ligament reconstruction with hamstring tendon grafts. These devices increase costs and can present artifacts in magnetic resonance imaging as well as complications in revision surgery. Therefore, a novel knot/press-fit technique that requires no implantable devices has been introduced. Null Hypothesis The knot/press-fit technique restores knee kinematics as well as the more commonly used EndoButton CL fixation and has similar biomechanical properties as other devices published in the literature. Study Design Controlled laboratory study. Methods Eight fresh-frozen cadaveric knees (52 ± 7 years) were tested using a robotic/universal force-moment sensor testing system. The knee kinematics of the intact, anterior cruciate ligament-deficient, EndoButton-reconstructed, and knot/pressfit-reconstructed knee in response to both a 134-N anterior tibial load and a combined rotatory load at multiple knee flexion angles was determined. Differences between the 4 knee states were evaluated with a 2-factor repeated-measures analysis of variance (P <. 05). To determine the stiffness and strength of the knot/press-fit fixation, the femur-graft-tibia complex was tested in uniaxial tension. Results In response to an anterior tibial load, the anterior tibial translation for the knot/press-fit reconstruction was found to be not significantly different from that of the intact anterior cruciate ligament as well as that of the EndoButton reconstruction (P >. 05). In response to a combined rotatory load, neither reconstruction procedure could effectively reduce the coupled anterior tibial translation to that of the intact knee, and no significant difference between the 2 reconstructions could be detected (P >. 05). The stiffness of the knot/press-fit complex was found to be 37.8 ± 9.6 N/mm, and the load at failure was 540 ± 97.7 N, which is equal to other devices published in the literature. Clinical Relevance The experiment suggests that the knot/press-fit technique may be a reliable alternative for the femoral fixation of hamstring tendon grafts.


2019 ◽  
Vol 27 (10) ◽  
pp. 3381-3389 ◽  
Author(s):  
Florian B. Imhoff ◽  
Julian Mehl ◽  
Brendan J. Comer ◽  
Elifho Obopilwe ◽  
Mark P. Cote ◽  
...  

2020 ◽  
Vol 8 (7) ◽  
pp. 232596712092615
Author(s):  
Theresa Diermeier ◽  
Sean J. Meredith ◽  
James J. Irrgang ◽  
Stefano Zaffagnini ◽  
Ryosuke Kuroda ◽  
...  

Background: The pivot-shift test has become more consistent and reliable and is a meaningful outcome measurement after anterior cruciate ligament reconstruction (ACLR). Purpose/Hypothesis: The purpose of this investigation was to assess patient-reported outcomes (PROs) and the quantitative pivot shift (QPS) preoperatively, at time zero immediately after anatomic ACLR, and after 24 months as well as the relationship between PROs and the QPS. It was hypothesized that anatomic ACLR would restore rotatory stability measured by the pivot-shift test and that QPS measurements would be positively correlated with PROs. Study Design: Cohort study; Level of evidence, 2. Methods: The ACL-injured and contralateral uninjured knees from 89 of 107 (83.2%) enrolled patients at 4 international centers were evaluated using a standardized pivot-shift test. Tibial acceleration was assessed with an inertial sensor, and lateral compartment translation was measured using an image analysis system preoperatively, at time zero immediately postoperatively, and at follow-up after 2 years. PROs were assessed at 12 and 24 months postoperatively with the International Knee Documentation Committee (IKDC) subjective knee form, Cincinnati Knee Rating System (CKRS), Marx activity rating scale, and activity of daily living score (ADLS). Results: The mean patient age at surgery was 27 years (range, 15-45 years). A positive pivot shift preoperatively (side-to-side difference in tibial acceleration, 2.6 ± 4.0 m/s2; side-to-side difference in anterior tibial translation, 2.0 ± 2.0 mm) was reduced at time zero postoperatively (side-to-side difference in tibial acceleration, –0.5 ± 1.3 m/s2; side-to-side difference in anterior tibial translation, –0.1 ± 1.0 mm). All PROs improved from preoperatively to final follow-up at 24 months: from 56.5 to 85.5 points for the IKDC ( P = .0001), from 28.8 to 32.4 points for the CKRS ( P = .04), from 11.2 to 7.9 points for the Marx ( P < .0001), and from 75.7 to 91.6 points for the ADLS ( P < .0001). Neither preoperative nor time zero postoperative rotatory laxity assessed by the pivot-shift test correlated with PROs at 24-month follow-up. A graft retear was observed in 4 patients (4.5%) within 2 years of follow-up. Conclusion: Anatomic ACLR resulted in significantly improved and acceptable PROs at 2-year follow-up and a low failure rate. Anatomic ACLR restored QPS measurements of anterior tibial translation and tibial acceleration to those of the contralateral knee immediately after surgery while still under anesthesia, but there was no correlation between the QPS preoperatively or at time zero after ACLR and PROs at 2-year follow-up.


Author(s):  
R. W. Colbrunn ◽  
J. E. Dumpe ◽  
T. F. Bonner ◽  
J. D. Kolmodin ◽  
W. K. Barsoum ◽  
...  

A pivot shift is a useful exam for evaluating anterior cruciate ligament (ACL) reconstruction surgery. A positive result is a perceived “clunk” and is quantified by the kinematics that occur during the tibial reduction phase. In vitro evaluation of ACL reconstruction techniques includes robotic testing of cadaveric knees where the applied loads represent estimated in situ loads. Early understanding of the mechanism of the pivot shift has resulted in a simplified representation where static “rotary loads” (10Nm valgus torque, 5Nm internal tibial torque) are applied at a few discrete flexion angles, and changes in anterior tibial translation (ATT) are compared [1]. Building upon this work, and with advances in technology, we are now able to create a robotic test that is more like the clinical exam. Our hypothesis was that kinematics produced during the robotically simulated pivot shift would be similar to the clinical pivot shift but would be significantly different from the rotary loads method. The ability for a test to produce larger kinematic differences between native and deficient states may suggest a more robust methodology by which to evaluate the efficacy of ACL reconstructions.


2019 ◽  
Vol 7 (5_suppl3) ◽  
pp. 2325967119S0020
Author(s):  
Thomas Neri ◽  
Antoine Lamotte ◽  
Tommaso Bonanzinga ◽  
Frederic Farizon ◽  
Remi Philippot

Objectives: The objective of this study was to compare the use of a laximeter and a triaxial accelerometer, for Anterolateral ligament injury diagnosis of in ACL deficient knee. We hypothesized that a triaxial accelerometer was more effective than a laximeter. Methods: A total of 11 cadaver knees were studied according to a new conservative dissection protocol without damage to the lateral structures. A GnRB® laximeter (Genourob, France) was used to determine anterior tibial translation (AP) of the tibia. Simultaneously, a KiRA® triaxial accelerometer (Kinetic Rapid Assessment) (OrthoKey, Italy) was used to determine two parameters: the AP translation and the Pivot Shift (PS). For each knee, 5 conditions were successively applied: intact knee (intact), knee with ALL (ALLsec) isolated section, knee with ALL and ACL section (ALL + ACLsec). Results: For the laximeter, the ACL and ALL sections led to a significant AP translation increase: + 2.1 mm for the ACL section, and + 0.9 mm for the ALL section. This difference was significant regardless of the level of force applied (p <0.05). For the triaxial accelerometer, the ACL and the ALL sections led to a significant AP translation increase: + 2.8 mm for ACL, and + 1.5 mm for ALL section. In contrast, for the PS, the increase was more consistent. There was a multiplier factor between the ACLsec condition and the ACL + ALLsec condition comparable to that between the intact condition and the ACLsec condition (P> 0.05). Conclusion: Whatever the device, the AP translation difference induced by the ALL injury, of the order of mm, remains too small to make the diagnosis of an ALL injury. The evaluation of the AP translation is therefore not a relevant to diagnostic an ALL injury. With greater increase, the evaluation of the rotatory laxity, through the PS test, is more relevant. In current practice, there is no clinical interest to use a laximeter or accelerometer on AP translation assessment to diagnosis an ALL injury in a deficient ACL knee. On the other hand, the use of a triaxial accelerometer to quantify the lateral tibial plateau acceleration in the pivot shift test appears to be relevant for detecting an ALL injury on a deficient ACL knee. These findings help provide clinical guidelines for more effective objective measures to diagnose ALL injury, and determine the most effective management for each patient.