scholarly journals Defining New Reference Intervals for Serum Free Light Chains in Individuals with Reduced Kidney Function: Results of the Population- Based on Iceland Screens Treats or Prevents Multiple Myeloma (iStopMM) Study

Blood ◽  
2021 ◽  
Vol 138 (Supplement 1) ◽  
pp. 542-542
Author(s):  
Thorir Einarsson Long ◽  
Olafur Skuli Indridason ◽  
Runolfur Palsson ◽  
Sæmundur Rögnvaldsson ◽  
Thorvardur Jon Love ◽  
...  

Abstract Background: In addition to serum protein electrophoresis (SPEP) and serum immunofixation (IFE), measurement of serum free light chains (FLC) has become the hallmark for detection, prognostication, and monitoring of monoclonal gammopathies. However, serum FLC levels are heavily dependent on kidney function due to discrepancy in the rate of kidney clearance of the FLC. As chronic kidney disease (CKD) is common in the general population, it is possible that a large number of individuals have false FLC results. A kidney reference interval (eGFR < 60) has previously been published based on small numers (N=688) for serum FLC ratio (0.37-3.10) instead of the standard reference interval (0.26-1.65), but no kidney reference exists for kappa (3.3-19.4mg/L) or lambda (5.7-26.3mg/L). The aim of this study was to define and improve the reference interval for individuals with various degree of decreased kidney function and assess its effect on prevalence of light chain monoclonal gammopathy of undetermined significance (LC-MGUS) among CKD patients. Methods: A total of 80,759 participants of the Iceland Screens, Treats or Prevents Multiple Myeloma (iStopMM) study were included. Participants were screened by SPEP and IFE as well as by serum FLC assay (Freelite®). Serum creatinine (SCr) value closest to the time of screening was used to calculate (CKD-EPI) eGFR. Participants with M-protein, eGFR >60 mL/min/1.73 m2, missing SCr measurements or more than 1 year from the SCr measurement to the iStopMM screening were excluded. Correlation was assessed graphically and using the Spearman correlation coefficient. A nonparametric bootstrapping method was used to calculate the 95% CI. Partitioning was determined based on the proportion of subgroups (sex, age, eGFR) outside the whole group reference interval (<0.9% or >4.1%). However, intervals were not partitioned if subgroups included few participants and/or if deemed more applicable and reasonable for clinical practice. LC-MGUS was defined as FLC ratio outside the reference interval and raised FLC level without evidence of monoclonal heavy chain on SPEP or IFE or end-organ damage attributed to the plasma cell proliferative disorder. Results: Of 75,422 individuals who were screened, 6,503 (12%) participants had eGFR < 60 mL/min/1.73 m2, without evidence of monoclonality on SPEP or IFE and were analysed further. The median (IQR) kappa level was 21.7 (16.6-29.4) mg/L, lambda level 19.0 mg/L (14.8-25.0) and FLC ratio 1.16 (0.97-1.39). Serum FLC levels increased with decreasing eGFR: serum free kappa (ρ= -0.44, p < 0.001), lambda (ρ= -0.39, p < 0.001), and FLC ratio (ρ= -0.15, p < 0.001). Using current reference intervals, 60% and 21% of persons had values outside the normal range for kappa and lambda, respectively. The FLC ratio was outside the standard reference interval in 9% and outside the kidney reference interval in 0.6% of participants. Based on these findings, we established new reference intervals for FLC and FLC ratio (Table). Participants on dialysis (N=26) had significantly higher median (IQR) serum free kappa 29.3 mg/L (26.1-57.6, p = 0.01) and lambda 25.1 mg/L (19.5-52.6, p = 0.01) than participants with eGFR 30-59, but no significant difference compared to participants with eGFR < 30 (p = 0.57). The FLC ratio in participants on dialysis was 1.22 (0.96-1.37), which was similar to participants with eGFR 45-59 (p = 0.63) and 30-44 (p = 0.34). Participants on dialysis had significantly lower FLC ratio than participants with eGFR < 30, or 1.31 (1.10-1.57, p = 0.02). Utilising our novel reference intervals, the crude prevalence of LC-MGUS in all participants with eGFR < 60 was 75 (1.2%), with no difference between participants with eGFR of 45-59, 30-44 and < 30, respectively. When the crude rate of LC-MGUS was compared to a rate based on previous reference intervals, the crude rate of both kappa and lambda LC-MGUS increased in participants with eGFR 45-59, eGFR 30-44 and eGFR < 30 (p<0.001). Conclusion: Current reference intervals for serum FLC and FLC ratio are inaccurate for patients with decreased kidney function. Here we propose new reference intervals for serum FLC and FLC ratio for use in patients with CKD which also seem to be accurate in patients on dialysis. Implementing these novel reference intervals is likely to increase the sensitivity and specificity of the analyses and lead to a more accurate diagnosis of monoclonal gammopathy in individuals with kidney dysfunction. Figure 1 Figure 1. Disclosures Kampanis: The Binding Site: Current Employment. Hultcrantz: Intellisphere LLC: Consultancy; Curio Science LLC: Consultancy; GlaxoSmithKline: Membership on an entity's Board of Directors or advisory committees, Research Funding; Amgen: Research Funding; Daiichi Sankyo: Research Funding. Durie: Amgen, Celgene/Bristol-Myers Squibb, Janssen, and Takeda: Consultancy; Amgen: Other: fees from non-CME/CE services . Harding: The Binding Site: Current Employment, Membership on an entity's Board of Directors or advisory committees, Patents & Royalties. Landgren: Janssen: Research Funding; Amgen: Honoraria; Janssen: Honoraria; Celgene: Research Funding; Janssen: Other: IDMC; Takeda: Other: IDMC; Amgen: Research Funding; GSK: Honoraria. Kristinsson: Amgen: Research Funding; Celgene: Research Funding.

Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 5002-5002
Author(s):  
Tiina Podymow ◽  
Ahsan Alam ◽  
Murray Vasilevsky ◽  
Roch Beauchemin ◽  
Chaim Shustik ◽  
...  

Abstract Abstract 5002 Background: Kidney failure is a major cause of morbidity in patients with Multiple Myeloma (MM). While up to half of MM patients can be shown to have renal impairment, 10% will become dialysis dependent. The main mechanism of kidney failure is cast nephropathy, which is linked to high amounts of circulating free light chains. A proposed strategy to prevent this outcome is the use of extended high cutoff (HCO) dialysis. An ongoing randomized controlled trial is testing the Gambro HCO1100 filter. Here we report the use of another dialyzer (Bellco Phylther), which has a smaller pore size than the Gambro filter, but which may prove to be as effective and is less costly. Methods: We present three patients with symptomatic MM, elevated κ or λ serum free light chains (>500mg/L), biopsy confirmed cast nephropathy, and kidney failure (estimated GFR <15ml/min/1.73 m2) requiring dialysis. In all patients, dialysis consisted of 10 hemodiafiltration dialysis sessions in the first two weeks and three times a week thereafter using a high flux Bellco Phylther HF22SD dialyzer (Bellco, Modena, Italy). All patients received concurrent chemotherapy: bortezomib 1.3mg/m2 IV and dexamethasone 40mg po on days 1, 4, 8 and 11 of a 21 day cycle and liposomal doxorubicin at 30mg/m2 on day 4 of every cycle. Serum free light chains were determined pre- and immediately post-dialysis using a nephelometric immunoassay (FREELITE, The Binding Site, Birmingham UK). Results: We observed significant (>50%) and rapid reductions in sFLCs. These reductions were sustained at 3 months in all cases, likely because of effective anti-myeloma treatment. Two of the three patients had recovery of kidney function and remain dialysis-independent at least 6 months after cessation of dialysis. Interestingly, the only patient that did not recover kidney function was also found to have tubulointerstitial disease on renal biopsy in addition to cast nephropathy. Conclusions: The HCO Bellco Phylther dialyzer appears effective in the rapid reduction of sFLCs in light chain MM patients with cast nephropathy requiring dialysis and concurrent anti-myeloma drug therapy. While the numbers are small, our review suggests that patients with uncomplicated MM cast nephropathy may benefit from aggressive hemodiafiltration with this HCO membrane. This dialysis membrane and protocol are worth considering for further study in patients with MM cast nephropathy. Disclosures: No relevant conflicts of interest to declare.


2013 ◽  
Vol 66 (11) ◽  
pp. 992-995
Author(s):  
Annalise E Zemlin ◽  
Megan A Rensburg ◽  
Hayley Ipp ◽  
Jurie J Germishuys ◽  
Rajiv T Erasmus

Monoclonal serum free light chain measurements are used to follow up and manage patients with monoclonal gammopathies, and abnormal serum free light chain ratios are associated with risk of progression in certain diseases. We aimed to validate the reference intervals in our population. Reference intervals for κ and λ free light chains were established on 120 healthy adults. Creatinine levels were measured to exclude renal dysfunction and serum protein electrophoresis was performed. All creatinine values were within normal limits. After exclusion of subjects with abnormal serum protein electrophoreses, 113 subjects were available for analysis. The 95% reference interval was 6.3–20.6 mg/L for κ free light chains, 8.7–25.9 mg/L for λ free light chains and 0.46–1.23 for free light chain ratio. Most of the values fell within the manufacturer's recommended limits and therefore could be used for our population.


Pathology ◽  
2021 ◽  
Vol 53 ◽  
pp. S4
Author(s):  
Karl W. Baumgart

2004 ◽  
pp. 154-156
Author(s):  
H.D. Carr-Smith ◽  
R. Abraham ◽  
G.P. Mead ◽  
H. Goodman ◽  
P. Hawkins ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document