scholarly journals Differences in carotid arterial morphology and composition between individuals with and without obstructive coronary artery disease: A cardiovascular magnetic resonance study

Author(s):  
Hunter R Underhill ◽  
Chun Yuan ◽  
James G Terry ◽  
Haiying Chen ◽  
Mark A Espeland ◽  
...  
PLoS ONE ◽  
2021 ◽  
Vol 16 (5) ◽  
pp. e0251040
Author(s):  
Johannes H. Riffel ◽  
Deborah Siry ◽  
Janek Salatzki ◽  
Florian Andre ◽  
Marco Ochs ◽  
...  

Background Cardiovascular magnetic resonance (CMR) is the current reference standard for the quantitative assessment of ventricular function. Fast Strain-ENCoded (fSENC)-CMR imaging allows for the assessment of myocardial deformation within a single heartbeat. The aim of this pilot study was to identify obstructive coronary artery disease (oCAD) with fSENC-CMR in patients presenting with new onset of chest pain. Methods and results In 108 patients presenting with acute chest pain, we performed fSENC-CMR after initial clinical assessment in the emergency department. The final clinical diagnosis, for which cardiology-trained physicians used clinical information, serial high-sensitive Troponin T (hscTnT) values and—if necessary—further diagnostic tests, served as the standard of truth. oCAD was defined as flow-limiting CAD as confirmed by coronary angiography with typical angina or hscTnT dynamics. Diagnoses were divided into three groups: 0: non-cardiac, 1: oCAD, 2: cardiac, non-oCAD. The visual analysis of fSENC bull´s eye maps (blinded to final diagnosis) resulted in a sensitivity of 82% and specificity of 87%, as well as a negative predictive value of 96% for identification of oCAD. Both, global circumferential strain (GCS) and global longitudinal strain (GLS) accurately identified oCAD (area under the curve/AUC: GCS 0.867; GLS 0.874; p<0.0001 for both), outperforming ECG, hscTnT dynamics and EF. Furthermore, the fSENC analysis on a segmental basis revealed that the number of segments with impaired strain was significantly associated with the patient´s final diagnosis (p<0.05 for all comparisons). Conclusion In patients with acute chest pain, myocardial strain imaging with fSENC-CMR may serve as a fast and accurate diagnostic tool for ruling out obstructive coronary artery disease.


2021 ◽  
Vol 9 (9) ◽  
Author(s):  
F. De Michele ◽  
F. S. Guerra ◽  
V. Forte ◽  
A. Carrieri ◽  
D. R. R. Chieppa ◽  
...  

Abstract Purpose of Review Myocardial infarction in the absence of coronary artery disease is caused by a variety of clinical conditions, so it is important to detect the specific causes in order to perform a better prognostic stratification of these patients. The aim of this review is to summarize the most important findings that established the role of CMR (cardiovascular magnetic resonance) to detect the MINOCA (myocardial infarction with non-obstructive arteries) patients and the importance to differentiate them from myocardial infarction patients. Recent Findings The role of CMR is crucial to diagnose the principal diseases involved in MINOCA, as demonstrated. The several MR sequences used in all the MINOCA patients showed different results for all the different causes of MINOCA and, surely, high-resolution MR with gadolinium enhancement has been considered the best method to differentiate the transmural lesions. Summary Another fundamental aspect to be considered is the experience of CMR radiologists, which represent the most important element for the right diagnosis of MINOCA. Surely, in the future, CMR will be the most important technique of choice for MINOCA patients, playing a key role in their management.


2020 ◽  
Vol 22 (1) ◽  
Author(s):  
Johan Kihlberg ◽  
Vikas Gupta ◽  
Henrik Haraldsson ◽  
Andreas Sigfridsson ◽  
Sebastian I. Sarvari ◽  
...  

Abstract Background Several cardiovascular magnetic resonance (CMR) techniques can measure myocardial strain and torsion with high accuracy. The purpose of this study was to compare displacement encoding with stimulated echoes (DENSE), tagging and feature tracking (FT) for measuring circumferential and radial myocardial strain and myocardial torsion in order to assess myocardial function and infarct scar burden both at a global and at a segmental level. Method 116 patients with a high likelihood of coronary artery disease (European SCORE > 15%) underwent CMR examination including cine images, tagging, DENSE and late gadolinium enhancement (LGE) in the short axis direction. In total, 97 patients had signs of myocardial disease and 19 had no abnormalities in terms of left ventricular (LV) wall mass index, LV ejection fraction, wall motion, LGE or a history of myocardial infarction. Thirty-four patients had myocardial infarct scar with a transmural LGE extent (transmurality) that exceeded 50% of the wall thickness in at least one segment. Global circumferential strain (GCS) and global radial strain (GRS) was analyzed using FT of cine loops, deformation of tag lines or DENSE displacement. Results DENSE and tagging both showed high sensitivity (82% and 71%) at a specificity of 80% for the detection of segments with > 50% LGE transmurality, and receiver operating characteristics (ROC) analysis showed significantly higher area under the curve-values (AUC) for DENSE (0.87) than for tagging (0.83, p < 0.001) and FT (0.66, p = 0.003). GCS correlated with global LGE when determined with DENSE (r = 0.41), tagging (r = 0.37) and FT (r = 0.15). GRS had a low but significant negative correlation with LGE; DENSE r = − 0.10, FT r = − 0.07 and tagging r = − 0.16. Torsion from DENSE and tagging had a weak correlation (− 0.20 and − 0.22 respectively) with global LGE. Conclusion Circumferential strain from DENSE detected segments with > 50% scar with a higher AUC than strain determined from tagging and FT at a segmental level. GCS and torsion computed from DENSE and tagging showed similar correlation with global scar size, while when computed from FT, the correlation was lower.


Sign in / Sign up

Export Citation Format

Share Document