scholarly journals Echocardiographic assessment of diastolic dysfunction in elderly patients with severe aortic stenosis before and after aortic valve replacement

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Hatice Akay Caglayan ◽  
Didrik Kjønås ◽  
Siri Malm ◽  
Henrik Schirmer ◽  
Assami Rösner

Abstract Background The 2016 guidelines of the American Society of Echocardiography (ASE) and European Association of Cardiovascular Imaging (EACVI) for evaluation of left ventricular (LV) diastolic dysfunction by Doppler flow and tissue Doppler- echocardiography do not adjust assessment of high filling pressures for patients with aortic stenosis (AS). However, most of the studies on this patient group indicate age independent specific diastolic features in AS. The aim of this study is to identify disease-specific range and distribution of diastolic functional parameters and their ability to identify high N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels as a marker for high filling pressures. Methods In this study, 169 patients who underwent surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) were prospectively enrolled. Resting echocardiography was performed including Doppler of the mitral inflow, pulmonary venous flow, tricuspid regurgitant flow and tissue Doppler in the mitral ring and indexed volume-estimates of the left atrium (LAVI). Echocardiography, and NT-proBNP levels were assessed before TAVR/SAVR and at two postoperative visits at 6 and 12 months. Results Pre- and postoperative values were septal e′; 5.1 ± 3.9, 5.2 ± 1.6 cm/s; lateral e′ 6.3 ± 2.1; 7.7 ± 2.7 cm/s; E/e′19 ± 8; 16 ± 7 cm/s; E velocity 96 ± 32; 95 ± 32 cm/s; LAVI 39 ± 8; 36 ± 8 ml/m2, pulmonary artery pressure (PAP) 39 ± 8; 36 ± 8 mmHg, respectively. The scoring recommended by ASE/EACVI detected elevated NT pro-BNP with a specificity of 25%. Adjusting thresholds towards PAP ≥ 40 mmHg, E velocity ≥ 100 cm/s, E deceleration time < 220 ms, and E/septal e′ ≥ 20 or septal e′ < 5.0 cm/s increased prediction of NT-proBNP levels ≥500 ng/L with substantially improved specificity (> 85%). Conclusion Diastolic echocardiographic parameters in AS indicate persistent impaired relaxation and NT-proBNP indicate elevated filling pressures in most of the patients, improving only modestly 6–12 months after TAVR and SAVR. Applying the 2016 ASE/EACVI recommendations for detection of elevated filling pressures to patients with AS, elevated NT pro-BNP levels could not be reliably detected. However, adjusting thresholds of the echocardiographic parameters increased specificities to useful diagnostic levels. Trial registration The study was prospectively approved by the regional ethical committee, REK North with the registration number: REK 2010/397-10.

2021 ◽  
Author(s):  
Hatice Akay Caglayan ◽  
Didrik Kjønås ◽  
Siri Malm ◽  
Henrik Schirmer ◽  
Assami Rösner

Abstract Background: The 2016 guidelines of the American Society of Echocardiography (ASE) and European Association of Cardiovascular Imaging (EACVI) for evaluation of left ventricular (LV) diastolic dysfunction by Doppler flow and tissue Doppler- echocardiography do not adjust assessment of high filling pressures for patients with aortic stenosis (AS). However, most of the studies on this patient group indicate age independent specific diastolic features in AS. The aim of this study is to identify disease-specific range and distribution of diastolic functional parameters and their ability to identify high N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels as a marker for high filling pressures.Methods: In this study, 169 patients who underwent surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) were prospectively enrolled. Resting echocardiography was performed including Doppler of the mitral inflow, pulmonary venous flow, tricuspid regurgitant flow and tissue Doppler in the mitral ring and indexed volume-estimates of the left atrium (LAVI). Echocardiography, and NT-proBNP levels were assessed before TAVR/SAVR and at two postoperative visits at 6 and 12 months. Results: Pre- and postoperative values were septal e´; 5.1±3.9, 5.2±1.6 cm/s; lateral e´ 6.3±2.1; 7.7±2.7 cm/s; E/e´19±8; 16±7 cm/s; E velocity 96±32; 95±32 cm/s; LAVI 39±8; 36±8 ml/m2, pulmonary artery pressure (PAP) 39±8; 36±8 mmHg, respectively. The scoring recommended by ASE/EACVI detected elevated NT pro-BNP with a specificity of 25%. Adjusting thresholds towards PAP ≥ 40 mmHg, E velocity ≥ 100 cm/s, E deceleration time < 220 ms, and E/septal e´ ≥ 20 or septal e´< 5.0 cm/s increased prediction of NT-proBNP levels ≥ 500 ng/L with substantially increased specificity (>85%).Conclusion: Diastolic echocardiographic parameters in AS indicate persistent impaired relaxation and NT-proBNP indicate elevated filling pressures in most of the patients, improving only modestly 6-12 months after TAVR and SAVR. Applying the 2016 ASE/EACVI recommendations for detection of elevated filling pressures to patients with AS, elevated NT pro-BNP levels could not be reliably detected. However, adjusting thresholds of the echocardiographic parameters increased specificities to useful diagnostic levels. Trial registration: The study was prospectively approved by the regional ethical committee, REK North with the registration number: REK 2010/397-10


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charbel Abi Khalil ◽  
Barbara Ignatiuk ◽  
Guliz Erdem ◽  
Hiam Chemaitelly ◽  
Fabio Barilli ◽  
...  

AbstractTranscatheter aortic valve replacement (TAVR) has shown to reduce mortality compared to surgical aortic valve replacement (sAVR). However, it is unknown which procedure is associated with better post-procedural valvular function. We conducted a meta-analysis of randomized clinical trials that compared TAVR to sAVR for at least 2 years. The primary outcome was post-procedural patient-prosthesis-mismatch (PPM). Secondary outcomes were post-procedural and 2-year: effective orifice area (EOA), paravalvular gradient (PVG) and moderate/severe paravalvular leak (PVL). We identified 6 trials with a total of 7022 participants with severe aortic stenosis. TAVR was associated with 37% (95% CI [0.51–0.78) mean RR reduction of post-procedural PPM, a decrease that was not affected by the surgical risk at inclusion, neither by the transcatheter heart valve system. Postprocedural changes in gradient and EOA were also in favor of TAVR as there was a pooled mean difference decrease of 0.56 (95% CI [0.73–0.38]) in gradient and an increase of 0.47 (95% CI [0.38–0.56]) in EOA. Additionally, self-expandable valves were associated with a higher decrease in gradient than balloon ones (beta = 0.38; 95% CI [0.12–0.64]). However, TAVR was associated with a higher risk of moderate/severe PVL (pooled RR: 9.54, 95% CI [5.53–16.46]). All results were sustainable at 2 years.


2002 ◽  
Vol 89 (4) ◽  
pp. 408-413 ◽  
Author(s):  
Harald P Kühl ◽  
Andreas Franke ◽  
David Puschmann ◽  
Friedrich A Schöndube ◽  
Rainer Hoffmann ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document