scholarly journals EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Carlo Chiesa ◽  
Katarina Sjogreen-Gleisner ◽  
Stephan Walrand ◽  
Lidia Strigari ◽  
Glenn Flux ◽  
...  

AbstractThe aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient–relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.

Author(s):  
Jinguo Zhang ◽  
Guanzhong Zhai ◽  
Bin Yang ◽  
Zhenhe Liu

Prostate cancer is one of the most common cancers in men. This cancer is often associated with indolent tumors with little or no lethal potential. Some of the patients with aggressive prostate cancer have increased morbidity and early deaths. A major complication in advanced prostate cancer is bone metastasis that mainly results in pain, pathological fractures, and compression of spinal nerves. These complications in turn cause severe pain radiating to the extremities and possibly sensory as well as motor disturbances. Further, in patients with a high risk of metastases, treatment is limited to palliative therapies. Therefore, accurate methods for the detection of bone metastases are essential. Technical advances such as single-photon emission computed tomography/ computed tomography (SPECT/CT) have emerged after the introduction of bone scans. These advanced methods allow tomographic image acquisition and help in attenuation correction with anatomical co-localization. The use of positron emission tomography/CT (PET/CT) scanners is also on the rise. These PET scanners are mainly utilized with 18F-sodium-fluoride (NaF), in order to visualize the skeleton and possible changes. Moreover, NaF PET/CT is associated with higher tracer uptake, increased target-to-background ratio and has a higher spatial resolution. However, these newer technologies have not been adopted in clinical guidelines due to lack of definite evidence in support of their use in bone metastases cases. The present review article is focused on current perspectives and challenges of computerized tomography (CT) applications in cases of bone metastases during prostate cancer.


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Natalie A. Bebbington ◽  
Bryan T. Haddock ◽  
Henrik Bertilsson ◽  
Eero Hippeläinen ◽  
Ellen M. Husby ◽  
...  

Abstract Background Computed tomography (CT) scans are routinely performed in positron emission tomography (PET) and single photon emission computed tomography (SPECT) examinations globally, yet few surveys have been conducted to gather national diagnostic reference level (NDRL) data for CT radiation doses in positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT). In this first Nordic-wide study of CT doses in hybrid imaging, Nordic NDRL CT doses are suggested for PET/CT and SPECT/CT examinations specific to the clinical purpose of CT, and the scope for optimisation is evaluated. Data on hybrid imaging CT exposures and clinical purpose of CT were gathered for 5 PET/CT and 8 SPECT/CT examinations via designed booklet. For each included dataset for a given facility and scanner type, the computed tomography dose index by volume (CTDIvol) and dose length product (DLP) was interpolated for a 75-kg person (referred to as CTDIvol,75kg and DLP75kg). Suggested NDRL (75th percentile) and achievable doses (50th percentile) were determined for CTDIvol,75kg and DLP75kg according to clinical purpose of CT. Differences in maximum and minimum doses (derived for a 75-kg patient) between facilities were also calculated for each examination and clinical purpose. Results Data were processed from 83 scanners from 43 facilities. Data were sufficient to suggest Nordic NDRL CT doses for the following: PET/CT oncology (localisation/characterisation, 15 systems); infection/inflammation (localisation/characterisation, 13 systems); brain (attenuation correction (AC) only, 11 systems); cardiac PET/CT and SPECT/CT (AC only, 30 systems); SPECT/CT lung (localisation/characterisation, 12 systems); bone (localisation/characterisation, 30 systems); and parathyroid (localisation/characterisation, 13 systems). Great variations in dose were seen for all aforementioned examinations. Greatest differences in DLP75kg for each examination, specific to clinical purpose, were as follows: SPECT/CT lung AC only (27.4); PET/CT and SPECT/CT cardiac AC only (19.6); infection/inflammation AC only (18.1); PET/CT brain localisation/characterisation (16.8); SPECT/CT bone localisation/characterisation (10.0); PET/CT oncology AC only (9.0); and SPECT/CT parathyroid localisation/characterisation (7.8). Conclusions Suggested Nordic NDRL CT doses are presented according to clinical purpose of CT for PET/CT oncology, infection/inflammation, brain, PET/CT and SPECT/CT cardiac, and SPECT/CT lung, bone, and parathyroid. The large variation in doses suggests great scope for optimisation in all 8 examinations.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 182
Author(s):  
Ayman Abouzayed ◽  
Sara S. Rinne ◽  
Hamideh Sabahnoo ◽  
Jens Sörensen ◽  
Vladimir Chernov ◽  
...  

Background: Gastrin-releasing peptide receptor (GRPR) is an important target for imaging of prostate cancer. The wide availability of single-photon emission computed tomography/computed tomography (SPECT/CT) and the generator-produced 99mTc can be utilized to facilitate the use of GRPR-targeting radiotracers for diagnostics of prostate cancers. Methods: Synthetically produced mercaptoacetyl-Ser-Ser-Ser (maSSS)-PEG2-RM26 and mercaptoacetyl-Ser-Glu-Ser (maSES)-PEG2-RM26 (RM26 = d-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2) were radiolabeled with 99mTc and characterized in vitro using PC-3 cells and in vivo, using NMRI or PC-3 tumor bearing mice. SPECT/CT imaging and dosimetry calculations were performed for [99mTc]Tc-maSSS-PEG2-RM26. Results: Peptides were radiolabeled with high yields (>98%), demonstrating GRPR specific binding and slow internalization in PC-3 cells. [99mTc]Tc-maSSS-PEG2-RM26 outperformed [99mTc]Tc-maSES-PEG2-RM26 in terms of GRPR affinity, with a lower dissociation constant (61 pM vs 849 pM) and demonstrating higher tumor uptake. [99mTc]Tc-maSSS-PEG2-RM26 had tumor-to-blood, tumor-to-muscle, and tumor-to-bone ratios of 97 ± 56, 188 ± 32, and 177 ± 79, respectively. SPECT/CT images of [99mTc]Tc-maSSS-PEG2-RM26 clearly visualized the GRPR-overexpressing tumors. The dosimetry estimated for [99mTc]Tc-maSSS-PEG2-RM26 showed the highest absorbed dose in the small intestine (1.65 × 10−3 mGy/MBq), and the effective dose is 3.49 × 10−3 mSv/MBq. Conclusion: The GRPR antagonist maSSS-PEG2-RM26 is a promising GRPR-targeting agent that can be radiolabeled through a single-step with the generator-produced 99mTc and used for imaging of GRPR-expressing prostate cancer.


2020 ◽  
Vol 34 (11) ◽  
pp. 799-806
Author(s):  
Koichiro Abe ◽  
Makoto Hosono ◽  
Takayuki Igarashi ◽  
Takashi Iimori ◽  
Masanobu Ishiguro ◽  
...  

Abstract The diagnostic reference levels (DRLs) are one of several effective tools for optimizing nuclear medicine examinations and reducing patient exposure. With the advances in imaging technology and alterations of examination protocols, the DRLs must be reviewed periodically. The first DRLs in Japan were established in 2015, and since 5 years have passed, it is time to review and revise the DRLs. We conducted a survey to investigate the administered activities of radiopharmaceuticals and the radiation doses of computed tomography (CT) in hybrid CT accompanied by single photon emission computed tomography (SPECT)/CT and positron emission tomography (PET)/CT. We distributed a Web-based survey to 915 nuclear medicine facilities throughout Japan and survey responses were provided by 256 nuclear medicine facilities (response rate 28%). We asked for the facility's median actual administered activity and median radiation dose of hybrid CT when SPECT/CT or PET/CT was performed for patients with standard habitus in the standard protocol of the facility for each nuclear medicine examination. We determined the new DRLs based on the 75th percentile referring to the 2015 DRLs, drug package inserts, and updated guidelines. The 2020 DRLs are almost the same as the 2015 DRLs, but for the relatively long-lived radionuclides, the DRLs are set low due to the changes in the Japanese delivery system. There are no items set higher than the previous values. Although the DRLs determined this time are roughly equivalent to the DRLs used in the US, overall they tend to be higher than the European DRLs. The DRLs of the radiation dose of CT in hybrid CT vary widely depending on each imaging site and the purpose of the examination.


2019 ◽  
Vol 65 (3) ◽  
Author(s):  
Hanna Piwowarska-Bilska ◽  
Aleksandra Supińska ◽  
Jacek Iwanowski ◽  
Adriana Tyczyńska ◽  
Bożena Birkenfeld

Positron emission tomography (PET) is currently the most advanced diagnostic imaging technology along with well-known techniques like magnetic resonance imaging (MRI) and computed tomography (CT). Tremendous technical progress in engineering, imaging and radiopharmacy has provided the basis for impressive technological advances in the field of nuclear medicine over the past 50 years. Current nuclear medicine can be divided into 2 groups: the classic, which uses gamma-cameras for single photon emission computed tomography (SPECT) imaging, and the more modern PET technique. The clinical PET technique requires: (i) patient administration of the radiopharmaceutical labelled with a positron emitter, (ii) recording of the gamma radiation emitted from the patient’s body with a dedicated PET/ CT scanner, (iii) processing and analysis of recorded images. This article presents the basics of PET technology and research, and describes new technical trends introduced by the leading manufacturers of PET/CT scanners.


2013 ◽  
Vol 54 (9) ◽  
pp. 1037-1045 ◽  
Author(s):  
Martin Biermann ◽  
Thomas Schwarzlmüller ◽  
Kristine Eldevik Fasmer ◽  
Bernt C Reitan ◽  
Boel Johnsen ◽  
...  

During the last decade, hybrid imaging has revolutionized nuclear medicine. Multimodal camera systems, integrating positron emission tomography (PET) or single photon emission computed tomography (SPECT) with computed tomography (CT) now combine the contrast provided by tumor-avid radioactive drugs with the anatomic precision of CT. While PET-CT to a great extent has replaced single-modality PET in adult oncology, the use of PET-CT in children has been controversial, since even the lowest dose CT protocols adds approximately 2 mSv to the radiation dose of about 4 mSv from the PET-study with F-18-fluorodeoxyglucose (F-18-FDG). The article describes the current techniques used, discusses radiation doses and gives an overview of current indications for PET-CT and SPECT-CT in children. Hybrid imaging with a tumor-avid radioactive drug provides extremely high contrast between tumor and background tissues, while the CT component helps to locate the lesion anatomically. Currently both PET-CT and SPECT-CT play a role in pediatric oncology; PET-CT using F-18-FDG particularly for staging and follow-up of lymphoma and brain cancer, bone and soft tissue sarcomas; SPECT-CT with I-123-metaiodobenzylguanidine (MIBG) for tumors of the sympathetic nervous system such as neuroblastoma and pheochromocytoma while the remaining neuroendocrine tumors are imaged with radioactively labeled somatostatin analogues. To reduce radiation dose, a low-dose CT in combination with ultrasound and/or magnetic resonance imaging for the assessment of anatomy is often preferred.


Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 477
Author(s):  
Diego Fernando López ◽  
Valentina Ríos Borrás ◽  
Juan Manuel Muñoz ◽  
Rodrigo Cardenas-Perilla ◽  
Luis Eduardo Almeida

Objective: To evaluate the correlation between metabolic bone activity measured by single photon emission computed tomography (SPECT) and the anatomic condylar characteristics acquired by computed tomography (CT), in patients with unilateral condylar hyperplasia (UCH). Method and Materials/Patients: Observational, descriptive study in a group of 71 patients with clinical diagnosis of UCH and indication of SPECT/CT. Bone SPECT images obtained in a gamma-camera GE Infina and processed in a station Xeleris 3 with the program Volumetrix MI Evolution for bone. CT images acquired in a PET/CT Biograph mcT20 equipment (Siemens) processed in a station Osirix V 7.5.1 (Pixmeo, Bomex, Switzerland). Results: The sample included 24 men (33.8%) and 47 women (66.2%). Active state UCH was detected in 40 (56.3%) cases (over 55% uptake in the affected condyle) and 38 (53.5%) presented mandibular deviation to the right side. No significant differences related to sex, age, or mandibular deviation side were found. Mandibular deviation was the only morphologic feature related to active/inactive UCH (p = 0.003). The likelihood of active CH was significantly higher in patients with mandibular deviation higher than 6 mm compared with <6 mm (odds ratio (OR): 3.51, confidence interval (CI) 95%: 1.27–9.72). Conclusion: There is a significant correlation between the magnitude of mandibular deviation quantified on CT and metabolic findings obtained by SPECT in patients with UCH. The risk of active UCH is 3.5 times higher in patients with a mandibular deviation ≥6 mm.