Hardening and softening characteristics of tubular cantilever beams under dynamic loading

2021 ◽  
pp. 225-231
Author(s):  
B. Wang ◽  
T.X. Yu ◽  
S.R. Reid
1996 ◽  
Vol 444 ◽  
Author(s):  
Maarten P. de Boer ◽  
Terry A. Michalske

AbstractWe have measured autoadhesion (e.g. stiction) of individual polysilicon beams by interferometric optical microscopy. Untreated cantilever beams were dried from water in air, while treated beams were coated with a hydrophobic molecular coating of octadecyltrichlorosilane (ODTS). Adhesion values obtained for beams adhered to the substrate over a long length (large d) are independent of beam length with values of 16.7 and 4.4 mJ/m2 for untreated and treated samples respectively. These values can be understood in terms of differences in surface chemistry and polysilicon roughness. Using the shortest length beam which remains attached to the substrate, adhesion values were 280 and 16 mJ/m2 respectively. These higher values may be a result of capillarity effects. We recommend that measurements be made on beams in which d is large, in contrast to the current practice of noting the shortest beam adhered.


Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.


2020 ◽  
Vol 65 (1) ◽  
pp. 137-144
Author(s):  
Marius-Vasile Pop

This paper presents a method to find the severity of a crack for cantilever beams that can be used to estimate the frequency drop due to the crack. The severity is found for the crack located at the location where the biggest curvature (or bending moment) is achieved. Because the fixing condition does not permit a symmetrical deformation around the crack, the apparent severity is smaller as the real one. The latter is found by the estimated value of the trend-line at the fixed end, it being constructed on points that consider the crack position (equidistant points in the proximity of the fixed end) and the resulted deflections.


2020 ◽  
Vol 49 (5) ◽  
pp. 439-445
Author(s):  
G. G. Savenkov ◽  
V. V. Stolyarov ◽  
A. V. Kuznetsov ◽  
Yu. I. Meshcheryakov
Keyword(s):  

2020 ◽  
Vol 40 (9) ◽  
pp. 732-735
Author(s):  
M. M. Matlin ◽  
V. A. Kazankin ◽  
E. N. Kazankina ◽  
A. I. Mozgunova

Sign in / Sign up

Export Citation Format

Share Document