Seismic design and response of a 14-story concentrically braced steel building

Author(s):  
L. Martinelli ◽  
F. Perotti ◽  
A. Bozzi
2017 ◽  
Vol 137 ◽  
pp. 211-227 ◽  
Author(s):  
Onur Seker ◽  
Bulent Akbas ◽  
Pinar Toru Seker ◽  
Mahmoud Faytarouni ◽  
Jay Shen ◽  
...  

1992 ◽  
Vol 19 (6) ◽  
pp. 1025-1031 ◽  
Author(s):  
R. G. Redwood ◽  
A. K. Jain

Extensive research into the inelastic seismic response of concentrically braced frames and their components has been carried out in the last two decades. This knowledge has now been incorporated into seismic design practice in several countries, notably the U.S.A., Canada, and New Zealand. In this paper, design specifications from these three countries, which derive largely from the same body of research, are compared. The basic design philosophy for concentrically braced steel frames, loading, and member detailing are examined. It is concluded that, in general, the Canadian specifications are in conformity with the available information and have many similar features to codes of the other countries. Significant differences exist in the classification of braced frames, between interstorey drift requirements, in the treatment of dual structural systems, and to a lesser extent in member detailing requirements. Some features of Canadian codes meriting review are identified. Key words: structural engineering, earthquakes, standards, steel, braced frame, ductility, concentric bracing, dual system.


2016 ◽  
Vol 10 (5) ◽  
pp. 253-262 ◽  
Author(s):  
Changhao Zhang ◽  
Jianhu Feng ◽  
Xuntao Wang

2013 ◽  
Vol 29 (3) ◽  
pp. 1043-1067 ◽  
Author(s):  
Ching-Yi Tsai ◽  
Keh-Chyuan Tsai ◽  
Pao-Chun Lin ◽  
Wai-Hang Ao ◽  
Charles W. Roeder ◽  
...  

This research investigates the brace-to-gusset connection designs to allow the braces buckle in the plane (IP) of the frame. In order to study the performance of the IP buckling brace connections with different design details, five 3,026 mm–long A36 H 175 × 175 × 7.5 × 11 mm braces were tested using cyclically increasing axial displacements. All specimens failed at an average axial strain less than 0.025 due to the brace fracture at the mid-length where severe local buckling had occurred. Pseudo-dynamic tests on a three-story special concentrically braced frame (SCBF) using the proposed brace end connection details for six A36 H 150 × 150 × 7 × 10 mm braces were conducted using the PGA = 597 cm/s2 LA03 record to confirm with the component tests. The knife plates and IP buckling braces sustained a peak 0.049 rad interstory drift under the design base earthquake without fracture. The highly nonlinear responses were satisfactorily predicted by OpenSees. Recommendations on the seismic design of the IP buckling brace connections are provided.


Sign in / Sign up

Export Citation Format

Share Document