Investigation of energy performance of a rammed earth built commercial office building in three different climate zones of Australia

2015 ◽  
pp. 111-116
2018 ◽  
Vol 158 ◽  
pp. 1023-1035 ◽  
Author(s):  
Nusrat Jung ◽  
Satu Paiho ◽  
Jari Shemeikka ◽  
Risto Lahdelma ◽  
Miimu Airaksinen

Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 325
Author(s):  
Giada Giuffrida ◽  
Maurizio Detommaso ◽  
Francesco Nocera ◽  
Rosa Caponetto

The renewed attention paid to raw earth construction in recent decades is linked to its undoubted sustainability, cost-effectiveness, and low embodied energy. In Italy, the use of raw earth as a construction material is limited by the lack of a technical reference standard and is penalised by the current energy legislation for its massive behaviour. Research experiences, especially transoceanic, on highly performative contemporary buildings made with natural materials show that raw earth can be used, together with different types of reinforcements, to create safe, earthquake-resistant, and thermally efficient buildings. On the basis of experimental data of an innovative fibre-reinforced rammed earth material, energy analyses are developed on a rammed earth building designed for a Mediterranean climate. The paper focuses on the influences that different design solutions, inspired by traditional bioclimatic strategies, and various optimised wall constructions have in the improvement of the energy performance of the abovementioned building. These considerations are furthermore compared with different design criteria aiming at minimising embodied carbon in base material choice, costs, and discomfort hours. Results have shown the effectiveness of using the combination of massive rammed earth walls, night cross ventilation, and overhangs for the reduction of energy demand for space cooling and the improvement of wellbeing. Finally, the parametric analysis of thermal insulation has highlighted the economic, environmental, and thermophysical optimal solutions for the rammed earth envelope.


2017 ◽  
Vol 206 ◽  
pp. 193-205 ◽  
Author(s):  
Jiangyan Liu ◽  
Huanxin Chen ◽  
Jiahui Liu ◽  
Zhengfei Li ◽  
Ronggeng Huang ◽  
...  

2020 ◽  
Vol 150 ◽  
pp. 01011
Author(s):  
Wical Cheikhi ◽  
Khadija Baba ◽  
Abderrahman Nounah ◽  
Choukri Cherradi

In a world context focused on energy efficiency and sustainable construction, returning to the use of raw earth in construction constitutes a good alternative to concrete construction, a system more energy consuming and yet more used nowadays. This return is justified by the excellent energy performance and the high level of thermal comfort provided by earth constructions in different climates. In cold climates, adding an insulation on earth walls has proven to be effective in improving their thermal performances. However, the influence of adding an insulation on the energy performance of rammed earth buildings in hot and arid climates remains to this day little explored. The present work comes in this order of ideas; it is based on a comparative study of the energetic performances of a mud building before and after the addition of the insulation. In order to compare between their performances, we have performed a simulation of the thermal behaviour of each by the dynamic thermal simulation software Design Builder.


Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 895 ◽  
Author(s):  
Ilaria Ballarini ◽  
Giovanna De Luca ◽  
Argun Paragamyan ◽  
Anna Pellegrino ◽  
Vincenzo Corrado

Directive 2010/31/EU promotes the refurbishment of existing buildings to change them into nearly zero-energy buildings (nZEBs). Within this framework, it is of crucial importance to guarantee the best trade-off between energy performance and indoor environmental quality (IEQ). The implications of a global refurbishment scenario on thermal and visual comfort are assessed in this paper pertaining to an existing office building. The retrofit actions applied to achieve the nZEB target consist of a combination of envelope and technical building systems refurbishment measures, involving both HVAC and lighting. Energy and comfort calculations were carried out through dynamic simulation using Energy Plus and DIVA, for the thermal and visual performance assessments, respectively. The results point out that energy retrofit actions on the building envelope would lead to significant improvements in the thermal performance, regarding both energy savings (−37% of the annual primary energy for heating) and thermal comfort. However, a daylighting reduction would occur with a consequent higher electricity demand for lighting (36%). The research presents a detailed approach applicable to further analyses aimed at optimizing the energy efficiency measures in order to reduce the imbalance between visual and thermal comfort and to ensure the best performance in both domains.


2009 ◽  
Vol 53 (10) ◽  
pp. 545-551 ◽  
Author(s):  
Amporn Kunchornrat ◽  
Pichai Namprakai ◽  
Peter T. du Pont

Sign in / Sign up

Export Citation Format

Share Document