scholarly journals Influence of inclined wall self-shading strategy on office building heat gain and energy performance in hot humid climate of Malaysia

Heliyon ◽  
2019 ◽  
Vol 5 (7) ◽  
pp. e02077 ◽  
Author(s):  
M.Z. Kandar ◽  
P.S. Nimlyat ◽  
M.G. Abdullahi ◽  
Y.A. Dodo
Author(s):  
Stanley Russell ◽  
Mark Weston ◽  
Yogi Goswami ◽  
Matthew Doll

Flex House is a flexible, modular, pre-fabricated zero energy building that can be mass produced and adapted easily to a variety of site conditions and plan configurations. The key factor shaping the design is central Florida’s hot humid climate and intense solar radiation. Flex house combines the wisdom of vernacular Florida houses with state of the art Zero Energy House technologies (ZEH.) A combined system of photovoltaic panels and solar thermal concentrating panels take advantage of the region’s abundant insolation in providing clean renewable energy for the house. Conservation is achieved with state of the art mechanical systems and innovative liquid desiccant dehumidification technology along with highly efficient lighting and appliances. The hybrid nature of the Flex house allows for both an open and closed system to take advantage of the seasonal temperature variation. Central Florida buildings can conserve energy by allowing natural ventilation to take advantage of passive cooling in the mild months of the year and use a closed system to utilize mechanical cooling when temperatures are too high for passive cooling strategies. The building envelope works equally well throughout the year combining an optimum level of insulation, resistance to air infiltration, transparency for daylight, and flexibility that allows for opening and closing of the house. Flex House is designed with a strong connection between interior spaces and the outdoors with carefully placed fenestration and a movable wall system which enables the house to transform in response to the temperature variations throughout the year. The house also addresses the massive heat gain that occurs through the roof, which can generate temperatures in excess of 140 degrees. Flex House incorporates a parasol-like outer structure that shades the roof, walls and courtyard minimizing heat gain through the building envelope. To be implemented on a large scale, ZEH must be affordable for people earning a moderate income. Site built construction is time consuming and wasteful and results in higher costs. Building homes in a controlled environment can reduce material waste, and construction costs while increasing efficiency. Pre-fabricating Flex House minimizes preparation time, waste and safety concerns and maximizes economy, quality control, efficiency and safety during the construction process. This paper is an account of the design and construction of Flex House, a ZEH for central Florida’s hot humid climate.


2018 ◽  
Vol 34 ◽  
pp. 02053
Author(s):  
Esra’a Sh. Abbaas ◽  
Ala’eddin A. Saif ◽  
MAC Munaaim ◽  
Md. Azree Othuman Mydin

The influence of courtyard on the thermal performance of Development Department office building in University Malaysia Perlis (UniMAP, Pauh Putra campus) is investigated through simulation study for the effect of ventilation on indoor air temperature and relative humidity of the building. The study is carried out using EnergyPlus simulator interface within OpenStudio and SketchUp plug in software to measure both of air temperature and relative humidity hourly on 21 April 2017 as a design day. The results show that the ventilation through the windows facing the courtyard has sufficient effect on reducing the air temperature compared to the ventilation through external windows since natural ventilation is highly effective on driving the indoor warm air out to courtyard. In addition, the relative humidity is reduced due to ventilation since the courtyard has high ability to remove or dilute indoor airborne pollutants coming from indoor sources. This indicates that the presence of courtyard is highly influential on thermal performance of the building.


Energy ◽  
2019 ◽  
Vol 169 ◽  
pp. 1166-1174 ◽  
Author(s):  
Waleed Khalid Alhuwayil ◽  
Muhammad Abdul Mujeebu ◽  
Ali Mohammed M. Algarny

10.29007/ghfx ◽  
2020 ◽  
Author(s):  
Onur Dursun ◽  
Feyza Durmuslar ◽  
Duhan Olmez

High-density urban areas contain large number of historical buildings whose structures and artistic values are protected by regulations. This restricts the improvements can be made to building envelope to reduce energy demand of historical buildings. Therefore, immediate urban surroundings (IUS) may play a central role on energy performance of historical buildings (EPHB). Yet, literature has provided little or no evidence, so far. To address the gap, the current experimental inquiry aims to test the significance of IUS’s influence on the EPHB. To achieve, historical structure in hot- humid climate was selected and surveyed thoroughly. Control and intervention cases were considered to measure the influence IUS. The control case corresponds to the former state of IUS; whereas the intervention described as the IUS which includes a recently built office block with reflective glass façade. The numerical result obtained from computational thermal simulations were used for comparison. Accordingly, the increase in heating demand substantially surpassed the decrease in cooling demand for the case under study. Therefore, a significant increase in total energy demand was observed in the presence of intervention. In addition, the energy performance of the individual volumes located in the lower floors presented higher fluctuations due to intervention’s shading effect.


Sign in / Sign up

Export Citation Format

Share Document