Surgically Treated Aneurysms Previously Coiled: Lessons Learned

Neurosurgery ◽  
2004 ◽  
Vol 54 (2) ◽  
pp. 300-305 ◽  
Author(s):  
Erol Veznedaroglu ◽  
Ronald P. Benitez ◽  
Robert H. Rosenwasser

Abstract OBJECTIVE Intravascular coil embolization of cerebral aneurysms has proved to be a safe and effective treatment in certain patient groups; however, this treatment is relatively new, and the long-term outcomes are unknown. One of the known complications is refilling of the aneurysm dome, which is seen in follow-up studies. This patient population poses unique technical difficulties for the neurosurgeon. We present a series of 18 patients who underwent surgery for residual aneurysms after coil remobilization. METHODS During a 5-year period, we performed surgery in 18 patients who had previously undergone coil embolization for their aneurysms. Of these aneurysms, four were in the anterior communicating artery, five were in the posterior communicating artery, three were in the internal carotid artery, three were in the posteroinferior cerebellar artery, and three were in the middle cerebral artery. One patient presented with rupture, one presented with acute IIIrd cranial nerve palsy, and the rest of the aneurysms were found on routine follow-up angiograms. Fifteen aneurysms were clipped, and in three patients, they were wrapped because the clip could not be placed adequately. RESULTS There were no major complications in any of the patients, and all had uneventful recoveries. The presence of coils in the aneurysm dome and/or neck made clipping and exposure of the aneurysm neck difficult, resulting in incomplete neck obliteration in three patients. CONCLUSION Operative clipping after previous coil embolization in aneurysms poses a unique problem for neurosurgeons. With the increasing use of coil embolization, this patient population will undoubtedly increase. The neurosurgeon should be aware of the difficulties and pitfalls encountered in these patients.

2018 ◽  
Vol 10 (7) ◽  
pp. 682-686 ◽  
Author(s):  
Matthew J Koch ◽  
Christopher J Stapleton ◽  
Scott B Raymond ◽  
Susan Williams ◽  
Thabele M Leslie-Mazwi ◽  
...  

IntroductionThe LVIS Blue is an FDA-approved stent with 28% metallic coverage that is indicated for use in conjunction with coil embolization for the treatment of intracranial aneurysms. Given a porosity similar to approved flow diverters and higher than currently available intracranial stents, we sought to evaluate the effectiveness of this device for the treatment of intracranial aneurysms.MethodsWe performed an observational single-center study to evaluate initial occlusion and occlusion at 6-month follow-up for patients treated with the LVIS Blue in conjunction with coil embolization at our institution using the modified Raymond–Roy classification (mRRC), where mRRC 1 indicates complete embolization, mRRC 2 persistent opacification of the aneurysm neck, mRRC 3a filling of the aneurysm dome within coil interstices, and mRRC 3b filling of the aneurysm dome.ResultsSixteen aneurysms were treated with the LVIS Blue device in conjunction with coil embolization with 6-month angiographic follow-up. Aneurysms were treated throughout the intracranial circulation: five proximal internal carotid artery (ICA) (ophthalmic or communicating segments), two superior cerebellar artery, two ICA terminus, two anterior communicating artery, two distal middle cerebral artery, one posterior inferior cerebellar artery, and two basilar tip aneurysms. Post-procedurally, there was one mRRC 1 closure, five mRRC 2 closures, and 10 mRRC 3a or 3b occlusion. At follow-up, all the mRRC 1 and mRRC 3a closures, 85% of the mRRC 3b closures and 75% of the mRRC 2 closures were stable or improved to an mRRC 1 or 2 at follow-up.ConclusionsThe LVIS Blue represents a safe option as a coil adjunct for endovascular embolization within both the proximal and distal anterior and posterior circulation.


2005 ◽  
Vol 102 (2) ◽  
pp. 348-354 ◽  
Author(s):  
William E. Thorell ◽  
Michael M. Chow ◽  
Richard A. Prayson ◽  
Mark A. Shure ◽  
Sung W. Jeon ◽  
...  

Object. Aneurysmal subarachnoid hemorrhage affects approximately 10/100,000 people per year. Endovascular coil embolization is used increasingly to treat cerebral aneurysms and its safety and durability is rapidly developing. The long-term durability of coil embolization of cerebral aneurysms remains in question; patients treated using this modality require multiple follow-up angiography studies and occasional repeated treatments. Methods. Optical coherence tomography (OCT) is an emerging imaging modality that uses backscattered light to produce high-resolution tomography of optically accessible biological tissues such as the eye, luminal surface of blood vessels, and gastrointestinal tract. Vascular OCT probes in the form of imaging microwires are presently available—although not Food and Drug Administration—approved—and may be adapted for use in the cerebral circulation. In this study the authors describe the initial use of OCT to make visible the neck of aneurysms created in a canine model and treated with coil embolization. Optical coherence tomography images demonstrate changes that correlate with the histological findings of healing at the aneurysm neck and thus may be capable of demonstrating human cerebral aneurysm healing. Conclusions. Optical coherence tomography may obviate the need for subsequent follow-up angiography studies as well as aid in the understanding of endovascular tissue healing. Data in this study demonstrate that further investigation of in vivo imaging with such probes is warranted.


Neurosurgery ◽  
2020 ◽  
Author(s):  
Alexander Sirakov ◽  
Krasimir Minkin ◽  
Marin Penkov ◽  
Kristian Ninov ◽  
Vasil Karakostov ◽  
...  

Abstract Background Wide-necked cerebral aneurysms in the setting of acute subarachnoid hemorrhage (SAH) remain difficult to treat with endovascular methods despite recent progress in the neuroendovascular field. Objective To evaluate the effectiveness and safety of the Comaneci device (Rapid Medical, Israel) in endovascular coil embolization of acutely ruptured, wide-necked sidewall, or bifurcation cerebral aneurysms. Methods We retrospectively reviewed 45 anterior communicating artery, 24 internal carotid artery, 21 middle cerebral artery bifurcation, 15 anterior cerebral artery, and 13 posterior circulation aneurysms, which were treated using Comaneci-assisted coil embolization from August 2017 to January 2019. We evaluated procedural complications, clinical outcomes, and mid-term angiographic follow-up. Immediate and 90 d-clinical outcome and radiological follow-up were obtained in all patients. Results Comaneci-assisted coil embolization was performed in 118 acutely ruptured aneurysms. The technique was carried out successfully in all cases. Simultaneous application of 2 separated Comaneci devices was performed in 8/118 cases (6.77%). Periprocedural thromboembolic complications related to the device were seen in 7/118 cases (5.93%) and severe vasospasm of the parent artery after manipulation of the Comaneci device occurred in 5/118 cases (4.2%). The procedural-related morbidity rate was 2.54%, and there was no procedural related mortality. Among the available survivors, angiographic follow-ups were obtained at 3 and 6 mo, and complete aneurysmal obliteration was confirmed in 81/112 (72.3%) and 75/112 (66.9%) cases, respectively. Mid-term follow-up reviewed total recanalization rate of 14.28%. Conclusion Comaneci-assisted embolization of wide-necked intracranial aneurysms in patients presenting with acute SAH is associated with high procedural safety and adequate occlusion rates. Furthermore, dual antiplatelet therapy can be safely avoided in this patient group.


2005 ◽  
Vol 18 (2) ◽  
pp. 1-5 ◽  
Author(s):  
Sepehr Sani ◽  
Kirk W. Jobe ◽  
Demetrius K. Lopes

Object Until recently, wide-necked aneurysms were not considered amenable to treatment with coil embolization. The recent introduction of intracranial stents has provided a method of preventing coil migration out of wide-necked aneurysms. The Neuroform2 Treo is a modification of the Neuroform stent; the new version has a higher metal/artery ratio. The authors' initial experience with the use of this stent in combination with coil embolization to treat wide-necked intracranial aneurysms is reported and technical considerations are discussed. Methods The authors' first 10 consecutive patients with wide-necked intracranial aneurysms were included in this study. Inclusion criteria restricted the group to adult patients with wide-necked intracranial aneurysms (ruptured and unruptured lesions). A wide neck was defined as a dome/neck ratio of less than 2 or a neck that was 4 mm or wider as measured on angiograms. Immediate postprocedure angiography studies were performed to determine successful coil occlusion of the aneurysm as well as patency of the parent vessel. Six-month follow-up angiograms were obtained in all patients. Ten aneurysms with poor dome/neck ratios (< 2) were studied in 10 patients. In all cases the stent was delivered to the aneurysm site and positioned without difficulty. No branch artery compromise was observed. A technical difficulty occurred in one case, with prolapse of a coil into the parent vessel, which was successfully corrected with no adverse clinical effects. There were no clinical or neurological complications associated with endovascular treatment of aneurysms in this series. One patient required further coil embolization because of findings on the 6-month follow-up cerebral angiogram. Conclusions The Neuroform2 Treo navigates similarly to the Neuroform2, with the advantage of increased aneurysm neck coverage. This feature may lower the retreatment rates for wide-necked cerebral aneurysms.


2017 ◽  
Vol 6 (3-4) ◽  
pp. 126-134 ◽  
Author(s):  
Ali Sultan-Qurraie ◽  
Ahsan Sattar ◽  
Wled Wazni ◽  
Mazen Noufal ◽  
Osama Zaidat

Introduction: The pipeline embolization device (PED) is increasingly used in the endovascular management of cerebral aneurysms. Longitudinal data regarding safety and benefit of the PED in anterior communicating (ACOM) artery aneurysms are limited and particularly lacking in residual ACOM artery aneurysms. We report the use of the PED in 3 patients with ACOM artery aneurysms who were previously coiled. Methods: Three patients with ACOM artery aneurysms, all previously treated with coiling and with recurrence of the aneurysm neck, were treated with the PED. All obtained follow-up diagnostic cerebral angiograms at either 3 or 6 months. Results: Mean age of patients was 59 years. All patients received cerebral angiograms at a minimum of 3 months after treatment with the PED. Follow-up angiography was performed up to a mean of 10 months at which time point all cases demonstrated complete aneurysm occlusion, without any stenosis in the parent artery. Conclusion: The PED can be safely used for the treatment of ACOM artery aneurysms. Complete aneurysm obliteration can be achieved in cases refractory to endovascular coiling. These findings warrant replication in a larger data set.


Neurosurgery ◽  
2006 ◽  
Vol 59 (suppl_5) ◽  
pp. S3-77-S3-92 ◽  
Author(s):  
Peter K. Nelson ◽  
Daniel Sahlein ◽  
Maksim Shapiro ◽  
Tibor Becske ◽  
Brian-Fred Fitzsimmons ◽  
...  

Abstract OBJECTIVE: The purposes of this article are to summarize recent developments and concerns in endovascular aneurysm therapy leading to the adjunctive use of endoluminal devices, to review the published literature on stent-supported coil embolization of cerebral aneurysms, and to describe our experience with this technique in a limited subgroup of problematic complex aneurysms over a medium-term follow-up period. METHODS: Between January 2003 and June 2004, 28 individuals among 157 patients with cerebral aneurysms we evaluated were identified as harboring aneurysms with exceptionally broad necks. Out of these 28 patients, 16 were treated with a combination of stents and detachable coils, preserving the parent artery. Recorded data included patient demographics, the clinical presentation, aneurysm location and characteristics, procedural details, and clinical and angiographic outcome. RESULTS: Over an 18-month period, 16 patients with large cerebral aneurysms additionally characterized by neck sizes between 7 and 14 mm were treated, using combined coil embolization of the aneurysm with stent reconstruction of the aneurysm neck. Thirteen out of the 16 aneurysms were occluded at angiographic reevaluation between 11 and 24 months (mean angiographic follow-up, 17.5 mo). There were no treatment-related deaths or clinically evident neurological complications. Thirteen patients experienced excellent clinical outcomes, with good outcomes in two patients and a poor visual outcome in one patient (mean clinical follow-up, 29 mo). A single technical complication occurred, involving transient nonocclusive stent-associated thrombus, which was treated uneventfully with abciximab. CONCLUSION: Stent-supported coil embolization of large, complex-neck cerebral aneurysms seems to provide superior medium-term anatomic reconstruction of the parent artery compared with historic series of aneurysms treated exclusively with endosaccular coils. In the near future, increasingly sophisticated endoluminal devices offering higher coverage of the neck defect will likely enable more definitive endovascular treatment of complex cerebral aneurysms and further expand our ability to manipulate the vascular biology of the parent artery.


2007 ◽  
Vol 107 (6) ◽  
pp. 1214-1216 ◽  
Author(s):  
Robert D. Ecker ◽  
Ricardo A. Hanel ◽  
Elad I. Levy ◽  
L. Nelson Hopkins

✓The authors report the successful staged stenting and coil embolization of a large vertebral artery–posterior inferior cerebellar artery (VA-PICA) aneurysm using the contralateral VA for access. A 67-year-old woman presented with a large ruptured VA-PICA aneurysm. Initial attempts to stent the wide-necked aneurysm from the ipsilateral side failed, so coil embolization of the dome was performed. During a second endovascular session, the aneurysm neck was successfully stented from the contralateral VA into the PICA. Six weeks later, coils were inserted into the aneurysm from the ipsilateral side. The coil result was stable at the 3-month follow-up examination.


2015 ◽  
Vol 21 (5) ◽  
pp. 566-574 ◽  
Author(s):  
Matías Negrotto ◽  
Roberto Crosa ◽  
Walter Casagrande

Background and purpose Endovascular treatment of broad-neck, complex cerebral aneurysms is a challenging issue. Placement of a stent over the aneurysm neck and secondary coil embolization prevents coil migration and allows dense packing of the coils. Another challenge is represented by distal aneurysms situated in small vessels. In these cases, the use of little stents, which we are going call ministents, could be a good decision. These low-profile intracranial ministents can be deployed into arteries with diameters between 1.5 and 3.10 mm and delivered through microcatheters with an internal diameter of 0.0165 inches, which allows easier navigation in small-sized, delicate vessels. We present six cases of wide-neck aneurysms, with small parental arteries less than 2.5 mm using a low-profile ministent system (LEO Baby and LVIS Jr) plus coil embolization. Materials and methods We retrospectively reviewed patients in whom LEO Baby or LVIS Jr stent was used for the treatment of intracranial aneurysms. Five aneurysms were treated during 2013–2014 in our service using the LEO Baby stent and one aneurysm using LVIS Jr. Stent-assisted coil embolization was performed using the jailing technique in all cases. Clinical and angiographic findings, procedural data, and follow-up are reported. Results Six consecutive patients were included in this study. Four patients presented with subarachnoid hemorrhage in the subacute–chronic phase and two patients had unruptured aneurysms. Two of the six aneurysms were located at branches of the sylvian artery, one at the basilar artery, two at the anterior communicating artery, and one at the P1–P2 artery. The procedures were successful. Six-month control digital subtraction angiograms were obtained in all cases; they demonstrated complete occlusion of the aneurysms in all instances. All patients had good clinical outcomes on follow-up, as measured with the Glasgow Outcome Scale and Modified Rankin Scale. Conclusions The results of this small study show that the LEO Baby and LVIS Jr ministents could be safe and efficient for endovascular treatment of intracranial broad-neck aneurysms situated in small arteries.


2008 ◽  
Vol 14 (4) ◽  
pp. 397-401 ◽  
Author(s):  
R. Ortiz ◽  
J. Song ◽  
Y. Niimi ◽  
A. Berenstein

Coil compaction and recanalization of cerebral aneurysms treated with coil embolization continue to be of great concern, especially in patients that presented with subarachnoid hemorrhage. The incidence of recanalization reported by previous studies ranges from 12 to 40 percent in experienced centers. We reviewed the incidence of recanalization requiring retreatment in patients treated with GDC 360 framing coils. A retrospective review of every patient who underwent coil embolization with GDC 360 coils for saccular aneurysms at our institution from December 2004 to March 2008 was performed. We studied the patients' demographics, clinical presentation, aneurysm size and configuration, type of coils used to embolize the aneurysm, the percentage of coils that were GDC 360 in any given aneurysm, the need for remodeling techniques like stent and/or balloon for embolization, immediate complications, cases in which we were unable to frame with the GDC 360 coil, and rate of recanalization on follow-up. A total of 110 patients (33 men, 77 women) and 114 aneurysms were treated with GDC 360 coils. Ninety-eight aneurysms were framed with the GDC 360 coils. There were two patients in whom the initial GDC 360 coil intended for framing had to be pulled out and exchanged for another type of coil. There were five procedure related complications (4.4%). Four patients required intra-arterial abciximab due to thrombus formation. One patient that presented with a grade III subarachnoid hemorrhage had aneurysm rupture while the coil was being advanced. A total of 50 patients (15 men and 35 women) underwent follow-up femoral cerebral angiograms at least six months after coiling (mean follow-up was 15 months). Forty-four of the patients with follow-up had the GDC 360 coil used as a framing coil. Three patients (6%) required retreatment due to recanalization. Every patient with recanalization requiring treatment had aneurysms of the anterior communicating complex that presented with subarachnoid hemorrhage. The rate of recanalization of cerebral aneurysms embolized with GDC 360 framing coils was lower in our case series compared to the existing literature reports. Patients with aneurysms of the anterior communicating artery were at increased incidence of recanalization in our patient cohort.


2015 ◽  
Vol 8 (4) ◽  
pp. 386-395 ◽  
Author(s):  
Friedhelm Brassel ◽  
Katharina Melber ◽  
Martin Schlunz-Hendann ◽  
Dan Meila

IntroductionY-configured stent assisted coiling is a promising therapeutic option to ensure safe coil embolization and preserve the affected arteries in complex wide necked aneurysms. We present our experience with self-expanding Acandis Acclino stents for the treatment of complex aneurysms using the kissing-Y technique.MethodsWe retrospectively reviewed seven patients with seven complex aneurysms (three anterior communicating artery (AcomA), two middle cerebral artery, one basilar artery/superior cerebellar artery, and one vertebral artery/posterior inferior cerebellar artery) who were treated with the kissing-Y technique by stent assisted coiling from June 2013 to July 2014, with follow-up until January 2015. DSA follow-up was up to 17 months, with a mean follow-up period of 10 months. Six patients were treated electively and one in the acute phase of a subarachnoid hemorrhage. In all cases, closed cell Acandis Acclino stents were used. We evaluated procedural complications, clinical outcomes, and mid term angiographic follow-up. Additionally, a literature review is provided.ResultsIn all patients, stents were successfully placed and implanted. One patient developed a periprocedural thromboembolic complication not directly related to the stents. No other periprocedural or postprocedural complications were encountered. Follow-up examinations showed stable and total occlusion of all coiled aneurysms.ConclusionsThe results of our study show that the kissing-Y technique using closed cell Acandis Acclino stents followed by coil embolization is a feasible treatment option for selected complex bifurcation aneurysms.


Sign in / Sign up

Export Citation Format

Share Document