Kissing-Y stenting for endovascular treatment of complex wide necked bifurcation aneurysms using Acandis Acclino stents: results and literature review

2015 ◽  
Vol 8 (4) ◽  
pp. 386-395 ◽  
Author(s):  
Friedhelm Brassel ◽  
Katharina Melber ◽  
Martin Schlunz-Hendann ◽  
Dan Meila

IntroductionY-configured stent assisted coiling is a promising therapeutic option to ensure safe coil embolization and preserve the affected arteries in complex wide necked aneurysms. We present our experience with self-expanding Acandis Acclino stents for the treatment of complex aneurysms using the kissing-Y technique.MethodsWe retrospectively reviewed seven patients with seven complex aneurysms (three anterior communicating artery (AcomA), two middle cerebral artery, one basilar artery/superior cerebellar artery, and one vertebral artery/posterior inferior cerebellar artery) who were treated with the kissing-Y technique by stent assisted coiling from June 2013 to July 2014, with follow-up until January 2015. DSA follow-up was up to 17 months, with a mean follow-up period of 10 months. Six patients were treated electively and one in the acute phase of a subarachnoid hemorrhage. In all cases, closed cell Acandis Acclino stents were used. We evaluated procedural complications, clinical outcomes, and mid term angiographic follow-up. Additionally, a literature review is provided.ResultsIn all patients, stents were successfully placed and implanted. One patient developed a periprocedural thromboembolic complication not directly related to the stents. No other periprocedural or postprocedural complications were encountered. Follow-up examinations showed stable and total occlusion of all coiled aneurysms.ConclusionsThe results of our study show that the kissing-Y technique using closed cell Acandis Acclino stents followed by coil embolization is a feasible treatment option for selected complex bifurcation aneurysms.

2018 ◽  
Vol 10 (7) ◽  
pp. 682-686 ◽  
Author(s):  
Matthew J Koch ◽  
Christopher J Stapleton ◽  
Scott B Raymond ◽  
Susan Williams ◽  
Thabele M Leslie-Mazwi ◽  
...  

IntroductionThe LVIS Blue is an FDA-approved stent with 28% metallic coverage that is indicated for use in conjunction with coil embolization for the treatment of intracranial aneurysms. Given a porosity similar to approved flow diverters and higher than currently available intracranial stents, we sought to evaluate the effectiveness of this device for the treatment of intracranial aneurysms.MethodsWe performed an observational single-center study to evaluate initial occlusion and occlusion at 6-month follow-up for patients treated with the LVIS Blue in conjunction with coil embolization at our institution using the modified Raymond–Roy classification (mRRC), where mRRC 1 indicates complete embolization, mRRC 2 persistent opacification of the aneurysm neck, mRRC 3a filling of the aneurysm dome within coil interstices, and mRRC 3b filling of the aneurysm dome.ResultsSixteen aneurysms were treated with the LVIS Blue device in conjunction with coil embolization with 6-month angiographic follow-up. Aneurysms were treated throughout the intracranial circulation: five proximal internal carotid artery (ICA) (ophthalmic or communicating segments), two superior cerebellar artery, two ICA terminus, two anterior communicating artery, two distal middle cerebral artery, one posterior inferior cerebellar artery, and two basilar tip aneurysms. Post-procedurally, there was one mRRC 1 closure, five mRRC 2 closures, and 10 mRRC 3a or 3b occlusion. At follow-up, all the mRRC 1 and mRRC 3a closures, 85% of the mRRC 3b closures and 75% of the mRRC 2 closures were stable or improved to an mRRC 1 or 2 at follow-up.ConclusionsThe LVIS Blue represents a safe option as a coil adjunct for endovascular embolization within both the proximal and distal anterior and posterior circulation.


2021 ◽  
pp. 159101992110034
Author(s):  
Tom De Beule ◽  
Thierry Boulanger ◽  
Sam Heye ◽  
Williem J van Rooij ◽  
Wim van Zwam ◽  
...  

Background and purpose The Woven EndoBridge (WEB) is an intrasaccular flowdisruptor that is increasingly used for the treatment of (wide-necked) aneurysms. We present our experience with the WEB for unruptured aneurysms. Materials and methods Between April 2014 and August 2019, 93 patients with 95 unruptured aneurysms were primarily treated with the WEB. There were 69 women and 24 men, mean age 61 years (median 58, range 37–80). Results Of 95 aneurysms, 86 had been discovered incidentally, 3 were symptomatic and 6 were additional to another ruptured aneurysm. Location was anterior communicating artery 33, middle cerebral artery 29, basilar tip 19, carotid tip 8, posterior communicating artery 4, posterior inferior cerebellar artery 1, superior cerebellar artery 1. Mean aneurysm size was 6 mm (median 6, range 3–13 mm). In one aneurysm additional coils were used and in another, a stent was placed. There was one procedural rupture without clinical sequelae. There were two thrombo-embolic complications leading to permanent deficit in one patient (mRS 2). Morbidity rate was 1.0% (1 of 93, 95%CI 0.01–6.5%) and mortality was 0% (0 of 93, 95%CI 0.0–4.8%). Angiographic follow-up at six months was available in 85 patients with 87 aneurysms (91%). Of 87 aneurysms, 68 (78%) were completely occluded, 14 (16%) had a neck remnant and 5 were incompletely occluded. Four aneurysms were retreated. Retreatment rate was 4.5% (4 of 87, 95%CI 1.7–13.6%). Conclusion WEB treatment of unruptured aneurysms is safe and effective. Additional devices are needed only rarely and retreatment at follow-up is infrequent.


2016 ◽  
Vol 9 (12) ◽  
pp. 1233-1237 ◽  
Author(s):  
Katharina Melber ◽  
Dan Meila ◽  
Philipp Draheim ◽  
Dominik Grieb ◽  
Björn Greling ◽  
...  

IntroductionSingle stent deployment leads to a change in vascular geometry in wide necked bifurcation aneurysms. In some complex cases, the use of the single stent technique might not be sufficient or may not be feasible. The kissing-Y stenting technique appears to be an alternative endovascular treatment option. The aim of this study was to evaluate the effects of the kissing-Y stenting technique on vascular angular remodeling.Methods21 patients with wide necked intracranial bifurcation aneurysms at different sites (10 anterior communicating artery, 6 middle cerebral artery, 3 basilar artery, 1 vertebral artery/posterior inferior cerebellar artery, 1 internal carotid artery/posterior communicating artery) were treated with 44 closed cell stents (follow-up 2012–2016) using the kissing-Y stenting technique. We analyzed vascular angle geometry between the mother and both affected daughter vessels by digital subtraction angiography, before and after stent deployment, using standard working projections.ResultsEndovascular treatment of wide necked intracranial aneurysms using the kissing-Y stenting technique significantly decreased the angle between the bifurcation branches from 130.4±9.5° to 91.5±9.1° (p<0.0001).ConclusionsKissing-Y stenting in wide necked bifurcation aneurysms leads to vascular angular remodeling of both affected branches. The resulting straightening of the bifurcation angle may prevent aneurysmal recurrence.


Neurosurgery ◽  
2014 ◽  
Vol 74 (5) ◽  
pp. 482-498 ◽  
Author(s):  
M. Yashar S. Kalani ◽  
Wyatt Ramey ◽  
Felipe C. Albuquerque ◽  
Cameron G. McDougall ◽  
Peter Nakaji ◽  
...  

Abstract BACKGROUND: Given advances in endovascular technique, the indications for revascularization in aneurysm surgery have declined. OBJECTIVE: We sought to define indications, outline technical strategies, and evaluate the outcomes of patients treated with bypass in the endovascular era. METHODS: We retrospectively reviewed all aneurysms treated between September 2006 and February 2013. RESULTS: We identified 54 consecutive patients (16 males and 39 females) with 56 aneurysms. Aneurysms were located along the cervical internal carotid artery (ICA) (n = 1), petrous/cavernous ICA (n = 1), cavernous ICA (n = 16), supraclinoid ICA (n = 7), posterior communicating artery (n = 2), anterior cerebral artery (n = 4), middle cerebral artery (MCA) (n = 13), posterior cerebral artery (PCA) (n = 3), posterior inferior cerebellar artery (n = 4), and vertebrobasilar arteries (n = 5). Revascularization was performed with superficial temporal artery (STA) to MCA bypass (n = 25), STA to superior cerebellar artery (SCA) (n = 3), STA to PCA (n = 1), STA-SCA/STA-PCA (n = 1), occipital artery (OA) to PCA (n = 2), external carotid artery/ICA to MCA (n = 15), OA to MCA (n = 1), OA to posterior inferior cerebellar artery (n = 1), and in situ bypasses (n = 8). At a mean clinical follow-up of 18.5 months, 45 patients (81.8%) had a good outcome (Glasgow Outcome Scale 4 or 5). There were 7 cases of mortality (12.7%) and an additional 9 cases of morbidity (15.8%). At a mean angiographic follow-up of 17.8 months, 14 bypasses were occluded. Excluding the 7 cases of mortality, the majority of aneurysms (n = 42) were obliterated. We identified 7 cases of residual aneurysm and recurrence in 6 patients at follow-up. CONCLUSION: Given current limitations with existing treatments, cerebral revascularization remains an essential technique for aneurysm surgery.


Neurosurgery ◽  
2004 ◽  
Vol 54 (2) ◽  
pp. 300-305 ◽  
Author(s):  
Erol Veznedaroglu ◽  
Ronald P. Benitez ◽  
Robert H. Rosenwasser

Abstract OBJECTIVE Intravascular coil embolization of cerebral aneurysms has proved to be a safe and effective treatment in certain patient groups; however, this treatment is relatively new, and the long-term outcomes are unknown. One of the known complications is refilling of the aneurysm dome, which is seen in follow-up studies. This patient population poses unique technical difficulties for the neurosurgeon. We present a series of 18 patients who underwent surgery for residual aneurysms after coil remobilization. METHODS During a 5-year period, we performed surgery in 18 patients who had previously undergone coil embolization for their aneurysms. Of these aneurysms, four were in the anterior communicating artery, five were in the posterior communicating artery, three were in the internal carotid artery, three were in the posteroinferior cerebellar artery, and three were in the middle cerebral artery. One patient presented with rupture, one presented with acute IIIrd cranial nerve palsy, and the rest of the aneurysms were found on routine follow-up angiograms. Fifteen aneurysms were clipped, and in three patients, they were wrapped because the clip could not be placed adequately. RESULTS There were no major complications in any of the patients, and all had uneventful recoveries. The presence of coils in the aneurysm dome and/or neck made clipping and exposure of the aneurysm neck difficult, resulting in incomplete neck obliteration in three patients. CONCLUSION Operative clipping after previous coil embolization in aneurysms poses a unique problem for neurosurgeons. With the increasing use of coil embolization, this patient population will undoubtedly increase. The neurosurgeon should be aware of the difficulties and pitfalls encountered in these patients.


2017 ◽  
Vol 24 (1) ◽  
pp. 4-13 ◽  
Author(s):  
P Bhogal ◽  
PA Brouwer ◽  
L Yeo ◽  
M Svensson ◽  
M Söderman

Background The aim of this study was to report our single centre experience with the Medina Embolic Device (MED). Methods We performed a retrospective analysis of prospectively collected data to identify all patients treated with the MED. A total of 14 aneurysms (non-consecutive), in 13 patients, were treated including one ruptured and one partially thrombosed aneurysm. Fundus diameter was ≥5 mm in all cases. We evaluated the angiographic appearances, the clinical status, complications, and the need for adjunctive devices or repeat treatments. Results Aneurysm location was cavernous internal carotid artery (ICA; n = 1), supraclinoid ICA ( n = 1), terminal ICA ( n = 2), anterior communicating artery (AComA; n = 4), A2–3 ( n = 1), M1–2 junction ( n = 1), posterior communicating artery (PComA; n = 1), superior cerebellar artery (SCA; n = 1), and basilar tip ( n = 2). The average aneurysm fundus size was 8.6 mm (range 7–10 mm) and average neck size 3.75 mm (range 1.9–6.9 mm). Immediate angiographic results were modified Raymond–Roy occlusion classification (mRRC) I n = 2, mRRC II n = 1, mRRC IIIa n = 2, mRRC IIIb n = 2, the remaining 7 aneurysms showed complete opacification. At follow-up angiography (mean 5 months) mRRC I n = 5, mRRC II n = 5, mRRC IIIa n = 3, and persistent filling was seen in 1 aneurysm. Overall, four patients had repeat treatment and one is pending further treatment. Of the aneurysms treated with more than one MED, 75% showed complete occlusion at 6-month follow up whereas only one aneurysm treated with a single device showed complete occlusion. Overall, three patients had temporary complications and there were no deaths. Conclusions The MED is an intra-saccular flow-diverting device with satisfactory angiographic results and an acceptable safety profile. Use of a single MED cannot be recommended and further longer term studies are needed prior to widespread clinical use.


2020 ◽  
Vol 12 (10) ◽  
pp. 987-992 ◽  
Author(s):  
Christopher Yusuf Akhunbay-Fudge ◽  
Kenan Deniz ◽  
Atul Kumar Tyagi ◽  
Tufail Patankar

Background and purposeWide-necked bifurcation aneurysms pose a significant challenge to the treating clinician. The Contour Neurovascular System embolization device is a novel tool for the treatment of such intracranial aneurysms. We report on our experience with this device.MethodsProspective clinical and radiological data were collected for all patients treated with the Contour device at our center. All our patients were treated on an elective basis.ResultsWe have treated 11 patients successfully with the Contour device to date. All patients were women with a mean (SD) age of 65.0 (6.4) years. In total, four basilar tip, two internal carotid artery, three middle cerebral artery, one anterior communicating artery, and one superior cerebellar artery aneurysms were treated. At 1-year follow-up, complete occlusion (Raymond Class 1) was seen in 55.56% (5/9) of cases, with 44.44% (4/9) having small neck remnants (Raymond Class 2). One patient declined 1-year catheter angiography and another had no further follow-up due to an unrelated medical condition. For six patients, 2-year radiological follow-up is available and shows stability. At 6 weeks, nine of the 11 patients had a modifed Rankin Scale score of 0, with two patients scoring 1 for headaches. Two patients had thromboembolic events, but there were no complications leading to permanent neurological disability or death. We additionally had three patients where the Contour device was attempted but was unable to be successfully used.ConclusionInitial results are promising although larger case numbers and longer follow-up are necessary to draw further conclusions on the utility and risk profile of this new device.


Author(s):  
Madan Mohan Balaguruswamy ◽  
Ezaz Mohamed ◽  
Krishnan Vijayan ◽  
Chaitanya S Juluri ◽  
Karuppannaswamy Madeswaran

Balloons are valuable tools in the armamentarium of a neurointerventionalist. In this report, we describe 2 cases in which a balloon aided in the navigation of a second remodeling balloon through difficult vascular anatomy. The first case was a patient with a ruptured proximal posterior inferior cerebellar artery aneurysm and the second case was a patient with a ruptured anterior communicating artery aneurysm. In both cases, the coiling microcatheter and the remodeling balloon catheters were advanced through different vessels. The remodeling balloon reached the target location using a transcirculation approach, and the navigation of the remodeling balloon was aided by utilizing a second balloon. Challenging vascular anatomy is often encountered when performing neuroendovascular procedures. The strategy of using balloon assistance for the transcirculation access of a remodeling balloon can be used successfully in difficult situations to manage complex aneurysms.


2010 ◽  
Vol 68 (1) ◽  
pp. 115-118 ◽  
Author(s):  
Eberval Gadelha Figueiredo ◽  
Luciano Foroni ◽  
Bernardo Assumpção de Monaco ◽  
Marcos Q.T. Gomes ◽  
Hugo Sterman Neto ◽  
...  

Fusiform and dolichoectatic aneurysms are challenging lesions to treat with direct clipping. Treatment of these aneurysms often requires alternative surgical strategies, including extracranial-intracranial bypass, wrapping, or clip-wrap techniques. Nonetheless, these alternatives methods of treatment have been underused and frequently overlooked. OBJECTIVE: To report a series of nine cases of otherwise untreatable aneurysms managed using the clip-wrap technique and discuss its surgical nuances. METHOD: In the last four years, 9 cases of ruptured aneurysms treated by the clip-wrap techniques were identified in the Division of Neurological Surgery, University of São Paulo, School of Medicine. RESULTS: The aneurysms were located at middle cerebral artery (2), anterior choroidal artery (1), anterior communicating artery (1), carotid ophthalmic (3), posterior cerebral artery (1) and posterior-inferior cerebellar artery (1). Three were dolichoectatic, 4 were unsuitable to complete surgical clipping because parent or efferent vessels arises from the aneurysm sac (1 MCA, 1 AcomA, 1 CO, 1 PICA aneurysms) and two, although ruptured aneurysms, were too small (<2mm) to be directly clipped. No early or late rebleeding was observed after 2 years mean follow-up. One patient deceased due to pulmonary tromboembolism. CONCLUSION: Clip-wrap techniques for the treatment of fusiform and otherwise unclippable aneurysms seem to be safe and it can be associated with a low rate of acute or delayed postoperative complications. It can prevent rebleeding and represents an improvement when compared with the natural history.


Sign in / Sign up

Export Citation Format

Share Document