scholarly journals High filtration in interventional practices reduces patient radiation doses but not always scatter radiation doses

2021 ◽  
Vol 94 (1117) ◽  
pp. 20200774
Author(s):  
Roberto M Sanchez ◽  
Eliseo Vano ◽  
Pablo Salinas ◽  
Nieves Gonzalo ◽  
Javier Escaned ◽  
...  

Objectives: In fluoroscopy-guided interventional practices, new dose reduction systems have proved to be efficient in the reduction of patient doses. However, it is not clear whether this reduction in patient dose is proportionally transferred to operators’ doses. This work investigates the secondary radiation fields produced by two kinds of interventional cardiology units from the same manufacturer with and without dose reduction systems. Methods: Data collected from a large sample of clinical procedures over a 2-year period (more than 5000 procedures and 340,000 radiation events) and the DICOM radiation dose structured reports were analysed. Results: The average cumulative Hp(10) per procedure measured at the C-arm was similar for the standard and the dose reduction systems (452 vs 476 μSv respectively). The events analysis showed that the ratio Hp(10)/KAP at the C-arm was (mean ± SD) 5 ± 2, 10 ± 4, 14 ± 4 and 14 ± 6 μSv·Gy−1·cm−2 for the beams with no added filtration, 0.1, 0.4 and 0.9 mm Cu respectively and suggested that the main cause for the increment of the ratio Hp(10)/KAP vs the “standard system” is the use of higher beam filtration in the “dose reduction” system. Conclusion: Dose reduction systems are beneficial to reduce KAP in patients and their use should be encouraged, but they may not be equally effective to reduce occupational doses. Interventionalists should not overlook their own personal protection when using new technologies with dose reduction systems. Advances in knowledge: Dose reduction technology in interventional systems may increase scatter dose for operators. Personal protection should not be overlooked with dose reduction systems.

2010 ◽  
Vol 6 (1) ◽  
pp. 15
Author(s):  
James P Earls ◽  
Jonathon A Leipsic ◽  
◽  

Recent reports have raised general awareness that cardiac computed tomography (CT) has the potential for relatively high effective radiation doses. While the actual amount of risk this poses to the patient is controversial, the increasing concern has led to a great deal of research on new CT techniques capable of imaging the heart at substantially lower radiation doses than was available only a few years ago. Methods of dose reduction include optimised selection of user-defined parameters, such as tube current and voltage, as well as use of new technologies, such as prospective triggering and iterative reconstruction. These techniques have each been shown to lead to substantial reduction in radiation dose without loss of diagnostic accuracy. This article will review the most frequently used and widely available methods for radiation dose reduction in cardiac CT and give practical advice on their use and limitations.


2016 ◽  
Vol 25 (4) ◽  
pp. 230-234
Author(s):  
Wai-Yung Yu ◽  
Thye Sin Ho ◽  
Henry Ko ◽  
Wai-Yee Chan ◽  
Serene Ong ◽  
...  

Introduction: The use of computed tomography (CT) imaging as a diagnostic modality is increasing rapidly and CT is the dominant contributor to diagnostic medical radiation exposure. The aim of this project was to reduce the effective radiation dose to patients undergoing cranial CT examination, while maintaining diagnostic image quality. Methods: Data from a total of 1003, 132 and 27 patients were examined for three protocols: CT head, CT angiography (CTA), and CT perfusion (CTP), respectively. Following installation of adaptive iterative dose reduction (AIDR) 3D software, tube current was lowered in consecutive cycles, in a stepwise manner and effective radiation doses measured at each step. Results: Baseline effective radiation doses for CT head, CTA and CTP were 1.80, 3.60 and 3.96 mSv, at currents of 300, 280 and 130–150 mA, respectively. Using AIDR 3D and final reduced currents of 160, 190 and 70–100 mA for CT head, CTA and CTP gave effective doses of 1.29, 3.18 and 2.76 mSv, respectively. Conclusion: We demonstrated that satisfactory reductions in the effective radiation dose for CT head (28.3%), CTA (11.6%) and CTP (30.1%) can be achieved without sacrificing diagnostic image quality. We have also shown that iterative reconstruction techniques such as AIDR 3D can be effectively used to help reduce effective radiation dose. The dose reductions were performed within a short period and can be easily achievable, even in busy departments.


2016 ◽  
Vol 9 (4) ◽  
pp. 384-388 ◽  
Author(s):  
Tanja Schneider ◽  
Emily Wyse ◽  
Monica S Pearl

BackgroundOne goal of increasing awareness of radiation dose is to encourage personal and technical modifications in order to reduce the radiation exposure of patients and staff.ObjectiveTo analyze the radiation doses incurred during diagnostic cerebral angiography and the angiographic techniques practiced over a 4-year period, in order to demonstrate the effectiveness of implementing radiation dose reduction strategies.MethodsA retrospective review of the first 50 consecutive adult and pediatric patients undergoing diagnostic cerebral angiography each year from 2010 to 2013 was performed. Angiograms and procedure examination protocols were reviewed for patient age, gender, diagnosis, angiography techniques, fluoroscopy time, reference point air kerma (Ka,r in mGy), and kerma-area product (PKA in μGym2).ResultsFrom January 2010 to June 2013, a total of 231 diagnostic cerebral angiograms were reviewed (200 adults, 31 children). Adult patients were aged from 19 to 94 years and included 77 men and 123 women. Pediatric patients were aged from 2 to 18 years and comprised 11 boys and 20 girls. Median Ka,r and PKA significantly decreased from 2010 to 2013 in adults (1867 mGy; 21 231 µGym2 vs 653 mGy; 7860 µGym2) and children (644 mGy; 6495 µGym2 vs138 mGy; 1465 µGym2), (p<0.001).ConclusionsIncreased awareness and implementation of dose reduction strategies resulted in decreased radiation doses for diagnostic cerebral angiography both in adult and pediatric patients. The use of lower and variable digital subtraction angiography frame rates and tailored examinations contributed significantly to the reduced radiation doses observed during diagnostic cerebral angiography.


Author(s):  
Jukka Järvinen ◽  
Joanna Sierpowska ◽  
Teemu Siiskonen ◽  
Hannu Järvinen ◽  
Tuomas Kiviniemi ◽  
...  

1965 ◽  
Vol 05 (01) ◽  
pp. 56-67
Author(s):  
I. Pál ◽  
J. Földes ◽  
I. Krasznai

SummaryThe authors investigated the use of 197Hg EDTA complex for kidney scanning. They describe the physical, biological and toxicological properties of the compound; its distribution within the organism, its excretion with urine and faeces and its uptake by the kidneys. The authors have established that the renal cortex selectively secretes the material which makes it suitable for kidney scanning. Some scintigrams of both normal and pathologic kidneys are presented.Finally a detailed discussion of the dosimetry is included. The radiation doses due to 197Hg EDTA are compared with those due to 203Hg-neohydrin and to intravenous pyelography. This comparison shows clearly that the use of 197Hg EDTA considerably decreases the radiation dose to the patient.


2012 ◽  
Vol 5 (8) ◽  
pp. 866-873 ◽  
Author(s):  
Kenneth A. Fetterly ◽  
Verghese Mathew ◽  
Ryan Lennon ◽  
Malcolm R. Bell ◽  
David R. Holmes ◽  
...  