scholarly journals Radiographic detection of artificially created horizontal root fracture using different cone beam CT units with small fields of view

2013 ◽  
Vol 42 (4) ◽  
pp. 20120261 ◽  
Author(s):  
K Kamburoğlu ◽  
B Önder ◽  
S Murat ◽  
H Avsever ◽  
S Yüksel ◽  
...  
2020 ◽  
Author(s):  
Fumi Mizuhashi ◽  
Ichiro Ogura ◽  
Yoshihiro Sugawara ◽  
Makoto Oohashi ◽  
Ryo Mizuhashi ◽  
...  

2015 ◽  
Vol 29 (1) ◽  
pp. 1-6 ◽  
Author(s):  
Fernanda Cristina Sales SALINEIRO ◽  
Lucas Rodrigues PINHEIRO ◽  
Oséas dos SANTOS JÚNIOR ◽  
Marcelo Gusmão Paraiso CAVALCANTI

2012 ◽  
Vol 29 (6) ◽  
pp. 489-493 ◽  
Author(s):  
Anne Caroline Costa Oenning ◽  
Sergio Lins de Azevedo Vaz ◽  
Saulo Leonardo Sousa Melo ◽  
Francisco Haiter-Neto
Keyword(s):  

Author(s):  
Masahiro Iikubo ◽  
Kaoru Kobayashi ◽  
Akira Mishima ◽  
Shinji Shimoda ◽  
Takayoshi Daimaruya ◽  
...  

2020 ◽  
Author(s):  
Jiahao Liang ◽  
Tiemei Wang ◽  
Dantong Cao ◽  
Ya Cao ◽  
Antian Gao ◽  
...  

Abstract AimUsing modified thermal cycling method to establish narrow root fracture models and evaluate the diagnosis efficiency of them using four different cone-beam CT (CBCT) units.MethodologyFifty-six intact teeth were selected and the crowns of the teeth were embedded using general purpose acrylic resin. 50 VRF models were established by soaking these teeth in liquid nitrogen and hot water cyclically; 6 teeth were used as negative control. All the 56 teeth were scanned with the smallest voxel size of four different CBCT units (NewTom VGi, Planmeca Promax 3D Max, Kavo 3D eXam and Soredex Scanora3D). The CBCT images were evaluated for the presence or absence of fracture lines. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operating characteristic curve (AUC) were calculated for the diagnosis of FLs using the four CBCT units. After that, 10 VRF teeth were randomly selected and the roots were sliced using slow-speed saw to obtain horizontal root sections with thickness of 2mm from enamel-cemental junction to the root apex and 25 root sections were finally obtained. Scanning electron microscope (SEM) was used to measure the width of the fracture lines (FLs) for each root section at one side.ResultsFifty narrow root fracture models were successfully established. There were totally 50 positive VRF models with 83 FLs and 6 negative VRF models. The diagnosis sensitivity was 0.24, 0.38, 0.29 and 0.19, the diagnosis specificity was 0.45, 0.16, 0.55, and 0.75, and the AUC was 0.60, 0.52, 0.59 and 0.61 for NewTom VGi, Planmeca Promax 3D Max, Soredex Scanora-3D and Kavo 3D eXam respectively. Randomly selected 10 models were sliced and 25 root sections with 45 FLs were acquired. The width of FLs was from 3.43μm to 143μm; 32.06% were less than 25μm, only 9.6% were from 75 to 150μm with SEM.ConclusionsThe modified temperature cycling method is a simple and effective method to establish narrow root fracture models, the diagnosis efficiency for these narrow fracture lines were quite poor using all the four different CBCT units.


2020 ◽  
pp. 20200450
Author(s):  
Amanda Pelegrin Candemil ◽  
Francesca Mangione ◽  
Karla Farias Vasconcelos ◽  
Anne Caroline Oenning ◽  
Reinhilde Jacobs ◽  
...  

Objectives: To evaluate the influence of exomass-related metal artefacts on the detection of simulated vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Methods: Twenty teeth were endodontically instrumented and VRF was induced in half of them. All teeth were individually placed in an empty socket of a human mandible. Metallic materials were differently arranged in the exomass [zone outside of the field of view (FOV) but between the X-ray source and the receptor] and/or endomass (zone inside of the FOV), and CBCT scans were obtained. Four radiologists evaluated the presence of VRF using a 5-point scale. Sensitivity, specificity, and area under the receiver operating curve (AUC) were compared using ANOVA. Also, the tooth of interest was replaced with a tube filled with a radiopaque solution and all CBCT scans were repeated to analyse the data objectively. Mean grey and noise values were obtained from the tube and compared using ANOVA followed by Tukey’s test (α = 0.05). Results: Mean grey values were significantly lower and noise was significantly higher when metallic materials were present in the endomass or both the exomass and endomass. Sensitivity, specificity, and AUC were not influenced by the artefacts from the metallic materials irrespective of the arrangement condition. Conclusions: Exomass-related metal artefacts did not influence the diagnosis of simulated VRF in CBCT.


2011 ◽  
Vol 37 (10) ◽  
pp. 1456-1459 ◽  
Author(s):  
Felipe Ferreira Costa ◽  
Bruno Felipe Gaia ◽  
Otavio Shoiti Umetsubo ◽  
Marcelo Gusmão Paraiso Cavalcanti

2012 ◽  
Vol 38 (6) ◽  
pp. 856-859 ◽  
Author(s):  
Felipe Ferreira Costa ◽  
Bruno Felipe Gaia ◽  
Otavio Shoiti Umetsubo ◽  
Lucas Rodrigues Pinheiro ◽  
Isabel Peixoto Tortamano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document