scholarly journals Quality assurance phantoms for cone beam computed tomography: a systematic literature review

2017 ◽  
Vol 46 (3) ◽  
pp. 20160329 ◽  
Author(s):  
Marcus V L de Oliveira ◽  
Ann Wenzel ◽  
Paulo S F Campos ◽  
Rubens Spin-Neto
Author(s):  
Oleksandr Nozhenko ◽  
Pavlo Snisarevskyi ◽  
Valentyna Zaritska

The purpose of this report is to highlight the histopathologic appearance of the mandibular simple bone cyst (SBC) – a pathologic condition which continues to stay an enigma for a lot of colleagues. Cone-beam computed tomography of a two-chamber SBC (ie, multilocular type) of the mandibular body in a 41-year-old white female is analyzed. Brief literature review is also performed giving the possibility to understand all intraoperative appearances of the SBCs and contemporary techniques of its management.


2019 ◽  
Vol 18 ◽  
pp. 153303381987077
Author(s):  
Maria F. Chan ◽  
Seng-Boh Lim ◽  
Xiang Li ◽  
Xiaoli Tang ◽  
Peng Zhang ◽  
...  

Purposes: The newly released Protura 6 degrees-of-freedom couch (CIVCO) has limited quality assurance protocols and pertinent publications. Herein, we report our experiences of the Protura system acceptance, commissioning, and quality assurance. Methods: The Protura system integration was tested with peripheral equipment on the following items: couch movement range limit, 6 degrees-of-freedom movement accuracy, weight test and couch sagging, system connection with Linac, isocentricity of couch and rotation alignment, kV and cone-beam computed tomography imaging of HexaCHECK with MIMI phantom (Standard Imaging), and an in-house custom 6 degrees-of-freedom quality assurance phantom. A couch transmission measurement was also performed. Results: The vertical, longitudinal, and lateral ranges of the 6 degrees-of-freedom couch pedestal are 43.9 to 0.0 cm, 24.6 to 149.5 cm, −20.6 to 20.7 cm, respectively. The couch movement accuracy was within 1 mm in all directions. The couch sagging with a 200 lbs (∼91 kg) evenly distributed object is 1.0 cm and 0.4° pitch in the distal end of the couch. The isocentricity of the couch was about 0.5 mm in diameter of all crosshair projections on the couch isocenter level, and the largest couch rotation alignment observed was (0.3°) at the couch angle of 90°. The deviation from the reference position (zero position) of the HexaCHECK phantom, measured by matching the cone-beam computed tomography with the reference planning computed tomography, was found to be below 0.2 mm in the anterior–posterior and right–left dimensions, 0.4 mm in superior–inferior dimension, and 0.1° in roll, pitch, and yaw directions. Conclusions: A 6 degrees-of-freedom quality assurance phantom is helpful for the commissioning and routine quality assurance tests. Due to the third-party integration with Linac, the system is prone to “double-correction” errors. A rigorous quality assurance program is the key to a successful clinical implementation of the Protura system.


2017 ◽  
Vol 22 (3) ◽  
pp. 258-263 ◽  
Author(s):  
Hideharu Miura ◽  
Shuichi Ozawa ◽  
Masahiro Hayata ◽  
Shintarou Tsuda ◽  
Tsubasa Enosaki ◽  
...  

2021 ◽  
Vol 17 ◽  
pp. 71-76
Author(s):  
Jonathan J. Wyatt ◽  
Rachel A. Pearson ◽  
Christopher P. Walker ◽  
Rachel L. Brooks ◽  
Karen Pilling ◽  
...  