scholarly journals A Two Parameters for the Evaluation of Hypovolemia in Patients with Septic Shock: Inferior Vena Cava Collapsibility Index (IVCCI), Delta Cardiac Output

2019 ◽  
Vol 25 ◽  
pp. 8105-8111
Author(s):  
Cem Kıvılcım Kaçar ◽  
Osman Uzundere ◽  
Abdulkadir Yektaş
2020 ◽  
Vol 26 (1) ◽  
Author(s):  
Tiffany A. Perkins ◽  
Alberic Rogman ◽  
Murali K. Ankem

Abstract Background Emphysematous pyelonephritis (EPN) with gas in the inferior vena cava (IVC) is a rare presentation and to our knowledge, this is the first case report in the urologic literature. Case presentation A 35-Year-old obese diabetic Hispanic female presented to the emergency room with a clinical picture of septic shock. Prompt computerized tomography scan revealed EPN with gas throughout the right renal parenchyma and extending to the right renal vein, IVC, and pulmonary artery. She died before surgical intervention Conclusion This case demonstrates that patients presenting with severe EPN have a high mortality risk and providers should acknowledge that septic shock, endogenous air emboli, or a combination of both could result in cardiovascular collapse and sudden death.


Critical Care ◽  
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Temistocle Taccheri ◽  
Francesco Gavelli ◽  
Jean-Louis Teboul ◽  
Rui Shi ◽  
Xavier Monnet

Abstract Background In patients ventilated with tidal volume (Vt) < 8 mL/kg, pulse pressure variation (PPV) and, likely, the variation of distensibility of the inferior vena cava diameter (IVCDV) are unable to detect preload responsiveness. In this condition, passive leg raising (PLR) could be used, but it requires a measurement of cardiac output. The tidal volume (Vt) challenge (PPV changes induced by a 1-min increase in Vt from 6 to 8 mL/kg) is another alternative, but it requires an arterial line. We tested whether, in case of Vt = 6 mL/kg, the effects of PLR could be assessed through changes in PPV (ΔPPVPLR) or in IVCDV (ΔIVCDVPLR) rather than changes in cardiac output, and whether the effects of the Vt challenge could be assessed by changes in IVCDV (ΔIVCDVVt) rather than changes in PPV (ΔPPVVt). Methods In 30 critically ill patients without spontaneous breathing and cardiac arrhythmias, ventilated with Vt = 6 mL/kg, we measured cardiac index (CI) (PiCCO2), IVCDV and PPV before/during a PLR test and before/during a Vt challenge. A PLR-induced increase in CI ≥ 10% defined preload responsiveness. Results At baseline, IVCDV was not different between preload responders (n = 15) and non-responders. Compared to non-responders, PPV and IVCDV decreased more during PLR (by − 38 ± 16% and − 26 ± 28%, respectively) and increased more during the Vt challenge (by 64 ± 42% and 91 ± 72%, respectively) in responders. ∆PPVPLR, expressed either as absolute or as percent relative changes, detected preload responsiveness (area under the receiver operating curve, AUROC: 0.98 ± 0.02 for both). ∆IVCDVPLR detected preload responsiveness only when expressed in absolute changes (AUROC: 0.76 ± 0.10), not in relative changes. ∆PPVVt, expressed as absolute or percent relative changes, detected preload responsiveness (AUROC: 0.98 ± 0.02 and 0.94 ± 0.04, respectively). This was also the case for ∆IVCDVVt, but the diagnostic threshold (1 point or 4%) was below the least significant change of IVCDV (9[3–18]%). Conclusions During mechanical ventilation with Vt = 6 mL/kg, the effects of PLR can be assessed by changes in PPV. If IVCDV is used, it should be expressed in percent and not absolute changes. The effects of the Vt challenge can be assessed on PPV, but not on IVCDV, since the diagnostic threshold is too small compared to the reproducibility of this variable. Trial registration: Agence Nationale de Sécurité du Médicament et des Produits de santé: ID-RCB: 2016-A00893-48.


2019 ◽  
Vol 6 (5) ◽  
pp. 1947
Author(s):  
Mohd Kashif Ali ◽  
Eeman Naim

Background: Ultrasound guided fluid assessment in management of septic shock has come up as an adjunct to the current gold standard Central Venous Pressure monitoring. This study was designed to observe the respiro-phasic variation of IVC diameter (RV-IVCD) in invasively mechanically ventilated and spontaneously breathing paediatric patients of fluid refractory septic shock.Methods: This was a prospective observational study done at Paediatric intensive Care Unit (PICU) in Paediatric ward of Jawaharlal Nehru Medical College and Hospital (JNMCH) from February 2016 to June 2017. 107 consecutive patients between 1 year to 16 years age who were in shock despite 40ml/kg of fluid administration were included. Inferior Vena Cava (IVC) diameters were measured at end-expiration and end inspiration and the IVC collapsibility index was calculated. Simultaneously Central Venous Pressure (CVP) was recorded. Both values were obtained in ventilated and non-ventilated patients. Data was analysed to determine to look for the profile of RV-IVCD and CVP in ventilated and non-ventilated cases.Results: Out of 107 patients, 91 were on invasive mechanical ventilation and 16 patients were spontaneously breathing. There was a strong negative correlation between central venous pressure (CVP) and inferior vena cava collapsibility (RV-IVCD) in both spontaneously breathing (-0.810) and mechanically ventilated patients (-0.700). Negative correlation was significant in both study groups in CVP <8 mmHg and only in spontaneously breathing patients in CVP 8-12 mmHg range. IVC collapsibility showed a decreasing trend with rising CVP in both spontaneously breathing and mechanically ventilated patients.Conclusion: Ultrasonography guided IVCCI appears to be a valuable index in assessing fluid status in both spontaneously breathing and mechanically ventilated septic shock patients. However, more data is required from the paediatric population so as to define it as standard of practice.


2020 ◽  
Vol 5 (1) ◽  

Fluid therapy is an essential component part management of critically ill patients. Proper estimation of the amount of needed fluids is of great importance due to the well-established adverse effects of marked negative and positive fluids balance. Central venous pressure has been widely used by ICU physicians for volume status assessment. Several methods have been postulated for volume status assessment, among which is the inferior vena cava collapsibility index. As the inferior vena cava is a thin-walled capacitance vessel that adjusts to the body’s volume status by changing its diameter depending on the total body fluid volume. Giving the fact that bed-side ultrasonographic measurement of inferior vena cava diameters is an available, non-invasive, reproducible and quiet easy-to-learn technique, it can provide a safe and quiet reliable replacement of central venous pressure measurement for assessment of volume status assessment. The aim of this study was to find statistical correlation between central venous pressure and caval index, as a step towards validating the above mentioned replacement. 86 critically ill patients from ICU population were enrolled. Simultaneous measurements of central venous pressure and inferior vena cava collapsibility index were observed and recorded on four sessions. Patients were also grouped based on their mode of ventilation and central venous pressure values in order to compare the strength of correlation between various populations. The results showed that Inferior vena cava collapsibility index has significant inverse correlation with CVP value (r= -85, p value ˂0.001 at 95% CI) and it better correlated with mean arterial blood pressure and lactate clearance as compared to central venous pressure. However it correlated better with CVP in spontaneously breathing patients (r= -0.86, p value ˂0.001) than in mechanically ventilated patients (r= -0.84, p value ˂0.001). Inferior vena cava collapsibility index has shown to correlate better with CVP value in lower values (˂ 10 cmH2O) (r= -0.8, p value ˂0.001) than in higher values (≥ 10 cmH2O) (r= -0.6, p value ˂0.001). In addition, an inferior vena caval collapsibility index cut-off value of 29% was shown to discriminate between CVP values ˂10 cmH2O and values ≥10 cmH2O with high Sensitivity (88.6%) and specificity (80.4%). In conclusion, inferior vena cava collapsibility index has a strong inverse relationship with central venous pressure which is more pronounced at low central venous pressure values. Point-of-care ultrasonographically-measured inferior vena cava collapsibility index is very likely to be a good alternative to central venous pressure measurement with a high degree of precision and reproducibility. However, Wide scale studies are needed to validate its use in different patient populations.


2019 ◽  
Vol 26 (1) ◽  
pp. 25
Author(s):  
AdemolaA Adeyekun ◽  
OguguaAnnie Ifijeh ◽  
AdenikeO Akhigbe ◽  
MohammedMunir Abubakar

2020 ◽  
pp. 026835552097413
Author(s):  
Yury Rusinovich ◽  
Volha Rusinovich

Aim This study examines respiratory biometry of inferior vena cava in patients with varicose veins of lower extremities. Material and Methods We performed retrospective analysis of clinical and ultrasound data of 67 patients with primary varicose veins. Results The largest expiratory (mean 16.2 mm, p-value 0.09) and inspiratory (mean 8.2 mm, p-value 0.02) inferior vena cava diameters were in C3 Clinical Etiological Anatomical Pathophysiological clinical class; the smallest expiratory diameters (mean 13.1 mm, p-value 0.5) were in C6 class; the smallest inspiratory diameters (mean 4.6 mm, intercept) were in C2 class. C2 class was associated with highest inferior vena cava collapsibility index (mean 68.2%, intercept); C6 class was associated with lowest collapsibility index (mean 48.3%, p-value 0.04). Recurrent varices in comparison with previously untreated were associated with smaller inspiratory diameters of inferior vena cava (mean 4.4 mm, p-value 0.005), smaller expiratory diameters (mean 13.4 mm, p-value 0.06) and higher collapsibility index (mean 68.5%, p-value 0.005). Patients with recurrent and bilateral varicose veins had identical respiratory biometry of inferior vena cava. Older age was associated with smaller inferior vena cava diameters (p-value <0.01). Conclusion Clinical presentation of varicose veins is associated with different respiratory biometry of suprarenal inferior vena cava. C6 clinical class in comparison with C2 clinical class is associated with lower central venous compliance possible due to the narrowing of inferior vena cava. Smaller inferior vena cava diameters and higher collapsibility index in recurrent subgroup in comparison with previously untreated can be a sign of the significantly altered pressure gradient between the systemic capillaries and the right heart and impaired peripheral venous return. Narrowing of inferior vena cava with age can be a sign of more profound changes in systemic venous return with age in patients with varicose veins in comparison to those without chronic venous disease.


2006 ◽  
Vol 101 (3) ◽  
pp. 866-872 ◽  
Author(s):  
Darija Baković ◽  
Davor Eterović ◽  
Zoran Valic ◽  
Žana Saratlija-Novaković ◽  
Ivan Palada ◽  
...  

Changes in cardiovascular parameters elicited during a maximal breath hold are well described. However, the impact of consecutive maximal breath holds on central hemodynamics in the postapneic period is unknown. Eight trained apnea divers and eight control subjects performed five successive maximal apneas, separated by a 2-min resting interval, with face immersion in cold water. Ultrasound examinations of inferior vena cava (IVC) and the heart were carried out at times 0, 10, 20, 40, and 60 min after the last apnea. The arterial oxygen saturation level and blood pressure, heart rate, and transcutaneous partial pressures of CO2and O2were monitored continuously. At 20 min after breath holds, IVC diameter increased (27.6 and 16.8% for apnea divers and controls, respectively). Subsequently, pulmonary vascular resistance increased and cardiac output decreased both in apnea divers (62.8 and 21.4%, respectively) and the control group (74.6 and 17.8%, respectively). Cardiac output decrements were due to reductions in stroke volumes in the presence of reduced end-diastolic ventricular volumes. Transcutaneous partial pressure of CO2increased in all participants during breath holding, returned to baseline between apneas, but remained slightly elevated during the postdive observation period (∼4.5%). Thus increased right ventricular afterload and decreased cardiac output were associated with CO2retention and signs of peripheralization of blood volume. These results indicate that repeated apneas may cause prolonged hemodynamic changes after resumption of normal breathing, which may suggest what happens in sleep apnea syndrome.


2019 ◽  
Vol 8 (5) ◽  
pp. 717
Author(s):  
Hee-Sun Park ◽  
Sung-Hoon Kim ◽  
Yong-Seok Park ◽  
Robert H. Thiele ◽  
Won-Jung Shin ◽  
...  

The aim of this study was to analyze whether the respiratory variation in electrocardiogram (ECG) standard lead II R-wave amplitude (ΔRDII) could be used to assess intravascular volume status following inferior vena cava (IVC) clamping. This clamping causes an acute decrease in cardiac output during liver transplantation (LT). We retrospectively compared ΔRDII and related variables before and after IVC clamping in 34 recipients. Receiver operating characteristic (ROC) curve and area under the curve (AUC) analyses were used to derive a cutoff value of ΔRDII for predicting pulse pressure variation (PPV). After IVC clamping, cardiac output significantly decreased while ΔRDII significantly increased (p = 0.002). The cutoff value of ΔRDII for predicting a PPV >13% was 16.9% (AUC: 0.685) with a sensitivity of 57.9% and specificity of 77.6% (95% confidence interval 0.561 – 0.793, p = 0.015). Frequency analysis of ECG also significantly increased in the respiratory frequency band (p = 0.016). Although significant changes in ΔRDII during vena cava clamping were found at norepinephrine doses <0.1 µg/kg/min (p = 0.032), such changes were not significant at norepinephrine doses >0.1 µg/kg/min (p = 0.093). ΔRDII could be a noninvasive dynamic parameter in LT recipients presenting with hemodynamic fluctuation. Based on our data, we recommended cautious interpretation of ΔRDII may be requisite according to vasopressor administration status.


Sign in / Sign up

Export Citation Format

Share Document