The ‘missing piece’ sign: distant migration of a patellar tendon cerclage wire

2010 ◽  
Vol 71 (8) ◽  
pp. 470-471
Author(s):  
Charles A Willis-Owen ◽  
Matthew J Crocker ◽  
David K Martin
2018 ◽  
Vol 46 (5) ◽  
pp. 1199-1204 ◽  
Author(s):  
Alex Rothfeld ◽  
Amanda Pawlak ◽  
Stephenie A.H. Liebler ◽  
Michael Morris ◽  
James M. Paci

Background: Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. Purpose/Hypothesis: The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Study Design: Controlled laboratory study. Methods: Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. Results: There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Conclusion: Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. Clinical Relevance: This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.


Author(s):  
Levent Ozcakar ◽  
Erkam Komurcu ◽  
Ismail Safaz ◽  
Ahmet Salim Goktepe ◽  
Kamil Yazicioğlu

Author(s):  
Sean P. McGowan ◽  
Benjamin C. Taylor ◽  
Devon M. Myers ◽  
Braden J. Passias

2019 ◽  
Vol 14 (12) ◽  
pp. 1509-1512
Author(s):  
Syed Mohammed Ali Haydar ◽  
Jonathan Miles ◽  
Rikin Hargunani

2019 ◽  
Vol 7 ◽  
pp. 2050313X1882310
Author(s):  
Tsuneari Takahashi ◽  
Tomohiro Matsumura ◽  
Kazuaki Ishihara ◽  
Shuhei Hiyama ◽  
Katsushi Takeshita

Knee dislocation with concomitant multiligament injury is a rare and devastating injury. We report the successful repair of a rare case of open knee dislocation with concomitant multiligament injury and patellar tendon rupture of an 18-year-old male due to a motorcycle accident. The patient presented with an open wound running parallel to the knee joint line and patellar tendon rupture with full exposure of the cartilage of the distal femur. Staged surgical management including the application of a ring-type external fixator with a hinged joint, lateral collateral ligament repair, medial collateral ligament reconstruction using autogenous hamstring tendon, and joint release was performed. Range of movement was recovered to 0 degrees of knee extension and 80 degrees of knee flexion, and extension lag was negative. The Lysholm score of the patient was recovered to 92. The patient was able to return to work in the construction field 2 years after sustaining the injury. The patient had no complaint of pain and was able to resume construction work, even though reconstruction of the anterior cruciate ligament and posterior cruciate ligament was not performed. The application of a hinged ring-type external fixation device might play a key role in early range of movement restoration and to maintain the reduced position and acceptable recovery of the posterior cruciate ligament injury without the need for reconstructive surgery. This report is the first to describe the safety and effectiveness of staged surgical management for the repair of open knee dislocation with concomitant multiligament injury and patellar tendon rupture. However, further studies with longer follow-up periods will be needed to observe the development of osteoarthritis or weakness of the knee. Staged surgical management is a safe and effective procedure for repairing an open knee dislocation with concomitant multiligament injury and patellar tendon rupture.


Data in Brief ◽  
2021 ◽  
Vol 36 ◽  
pp. 106976
Author(s):  
Aapo Ristaniemi ◽  
Jari Torniainen ◽  
Tommi Paakkonen ◽  
Lauri Stenroth ◽  
Mikko A.J. Finnilä ◽  
...  

2021 ◽  
Vol 9 (3) ◽  
pp. 232596712098590
Author(s):  
Brendon C. Mitchell ◽  
Matthew Y. Siow ◽  
Andrew T. Pennock ◽  
Eric W. Edmonds ◽  
Tracey P. Bastrom ◽  
...  

Background: Opioid consumption and patient satisfaction are influenced by a surgeon’s pain-management protocol as well as the use of adjunctive pain mediators. Two commonly utilized adjunctive pain modifiers for anterior cruciate ligament (ACL) reconstruction are femoral nerve blockade and intra-articular injection; however, debate remains regarding the more efficacious methodology. Hypothesis: We hypothesized that intra-articular injection with ropivacaine and morphine would be found to be as efficacious as a femoral nerve block for postoperative pain management in the first 24 hours after bone–patellar tendon–bone (BTB) ACL reconstruction. Study Design: Cohort study; Level of evidence, 3. Methods: Charts were retrospectively reviewed for BTB ACL reconstructions performed by a single pediatric orthopaedic surgeon from 2013 to 2019. Overall, 116 patients were identified: 58 received intra-articular injection, and 58 received single-shot femoral nerve block. All patients were admitted for 24 hours. Pain scores were assessed every 4 hours. Morphine milligram equivalents (MMEs) consumed were tabulated for each patient. Results: Opioid use was 24.3 MMEs in patients treated with intra-articular injection versus 28.5 MMEs in those with peripheral block ( P = .108). Consumption of MMEs was greater in the intra-articular group in the 0- to 4-hour period (7.1 vs 4.6 MMEs; P = .008). There was significantly less MME consumption in patients receiving intra-articular injection versus peripheral block at 16 to 20 hours (3.2 vs 5.6 MMEs; P = .01) and 20 to 24 hours (3.8 vs 6.5 MMEs; P < .001). Mean pain scores were not significantly different over the 24-hour period (peripheral block, 2.7; intra-articular injection, 3.0; P = .19). Conclusion: Within the limitations of this study, we could identify no significant difference in MME consumption between the single-shot femoral nerve block group and intra-articular injection group in the first 24 hours postoperatively. While peripheral block is associated with lower opioid consumption in the first 4 hours after surgery, patients receiving intra-articular block require fewer opioids 16 to 24 hours postoperatively. Given these findings, we propose that intra-articular injection is a viable alternative for analgesia in adolescent patients undergoing BTB ACL reconstruction.


Sign in / Sign up

Export Citation Format

Share Document