G1305 Numerical Analysis of Flows through a Packed Bed : Anisotropic Packed Beds

2001 ◽  
Vol 2001 (0) ◽  
pp. 261
Author(s):  
Hidetsugu Kimura ◽  
Ryozo Ishiwata
Author(s):  
F. I. Molina-Herrera ◽  
C. O. Castillo-Araiza ◽  
H. Jiménez-Islas ◽  
F. López-Isunza

Abstract This is a theoretical study about the influence of turbulence on momentum and heat transport in a packed-bed with low tube to particle diameter ratio. The hydrodynamics is given here by the time-averaged Navier-Stokes equations including Darcy and Forchheimer terms, plus a κ-ε two-equation model to describe a 2D pseudo-homogeneous medium. For comparison, an equivalent conventional flow model has also been tested. Both models are coupled to a heat transport equation and they are solved using spatial discretization with orthogonal collocation, while the time derivative is discretized by an implicit Euler scheme. We compared the prediction of radial and axial temperature observations from a packed-bed at particle Reynolds numbers (Rep) of 630, 767, and 1000. The conventional flow model uses effective heat transport parameters: wall heat transfer coefficient (hw) and thermal conductivity (keff), whereas the turbulent flow model includes a turbulent thermal conductivity (kt), estimating hw via least-squares with Levenberg-Marquardt method. Although predictions of axial and radial measured temperature profiles with both models show small differences, the calculated radial profiles of the axial velocity component are very different. We demonstrate that the model that includes turbulence compares well with mass flux measurements at the packed-bed inlet, yielding an error of 0.77 % in mass flux balance at Rep = 630. We suggest that this approach can be used efficiently for the hydrodynamics characterization and design and scale-up of packed beds with low tube to particle diameter ratio in several industrial applications.


2021 ◽  
Author(s):  
Octavian G. Pop ◽  
Florin Bode ◽  
Charles Berville ◽  
Cristiana Croitoru

2019 ◽  
Vol 9 (12) ◽  
pp. 2569
Author(s):  
Philipp Knödler

Thermal energy storage (TES) systems are central elements for various types of new power plant concepts, whereat packed beds represent a promising storage inventory option. Due to thermal expansion and shrinking of the packed bed’s particles during cyclic thermal charging and discharging operation, high technical risks arise, and possibly lead to material failure. In order to accurately design the heat storage system, suitable tools for calculating induced forces and stresses are mandatory. Continuum models offer time efficient simulation results, but are in need of effective packed bed parameters. This paper introduces a methodology for applying a simplified continuum model and presents first results for an exemplarily large-scale application.


2003 ◽  
Vol 125 (4) ◽  
pp. 693-702 ◽  
Author(s):  
G. Buonanno ◽  
A. Carotenuto ◽  
G. Giovinco ◽  
N. Massarotti

The upper and lower bounds of the effective thermal conductivity of packed beds of rough spheres are evaluated using the theoretical approach of the elementary cell for two-phase systems. The solid mechanics and thermal problems are solved and the effects of roughness and packed bed structures are also examined. The numerical solution of the thermal conduction problem through the periodic regular arrangement of steel spheroids in air is determined using the Finite Element Method. The numerical results are compared with those obtained from an experimental apparatus designed and built for this purpose.


Sign in / Sign up

Export Citation Format

Share Document