scholarly journals Noise-control of Blower and Compressor in Iron and Steel Plant ( on Noise Prevention of Pneumatic Machine)

1964 ◽  
Vol 67 (547) ◽  
pp. 1271-1276
Author(s):  
Kenzo FUKADA
2020 ◽  
Vol 273 ◽  
pp. 123163
Author(s):  
Wenqi Long ◽  
Shanshan Wang ◽  
Chunyang Lu ◽  
Ruoyu Xue ◽  
Tian Liang ◽  
...  

Atmosphere ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 833
Author(s):  
Zijie Lin ◽  
Fujiang Wang ◽  
Tao Ji ◽  
Baolong Ma ◽  
Linyan Xu ◽  
...  

Fugitive particle emission of enclosed storage yards in iron and steel plant is a complicated and multivariable problem, which will have negative impacts on the environment and economy. Researchers have discussed methodologies of emission estimation in open storage yards, but rarely focused on enclosed ones. However, enclosed storage yards are commonly adopted in most industries in China. This paper links onsite observation and computational fluid dynamics (CFD) to estimate the impact of fugitive PM10 emissions from enclosed storage yards on the open air. By collecting and analyzing PM10 samples at three sites inside the yard and one site outside, The result shows that PM10 concentration is in the range of 7.3 ± 1.5~13.4 ± 4.2 mg/m3, which is extremely high in an enclosed storage yard, and significantly influences workers’ health inside and outside atmospheric aerosols. The CFD model simulation is conducted by considering particle deposition, particle emission sources of shovel loader and road dust emission, as well as different wind direction and wind speed. The result shows that PM10 discharge rate from the enclosed area to open-air is significantly influenced by wind velocity and direction, e.g., the result of northwest wind with wind speed in 12.7 m/s is eight times higher than wind speed in 2.5 m/s with the same wind direction, and are 47 and 62 times higher than the east and west wind direction with the same wind speed in 12.7 m/s, respectively. In this case, the PM10 discharge rate is about 131.7 ton/year, which contains about 38~55 ton/year iron-relating particles. This will directly contribute PM10 to open-air and may produce secondary aerosols, due to heterogeneous catalytic reaction. This work identifies the important contribution of fugitive emissions and provides an approach for fugitive emission estimation of industries to the surrounding air. The results provide a reference for material yard zoning and fugitive emission control from minimizing influence from the meteorological condition and reducing source discharge inside.


2012 ◽  
Vol 610-613 ◽  
pp. 2228-2231 ◽  
Author(s):  
Jun Song ◽  
An Chao Zhang ◽  
Hai Kun Zheng

This paper analyzes the byproduct gas utilization and management status of china's iron and steel plant, point out that the dynamic optimization of surplus gas distribution has a very important position in the management of gas system, and a common model is established using mixed integer MILP (linear programming) method. Two typical enterprise application results show that: The model suitable for different types of iron and steel plant; optimization model can take full account of the characteristics of the adjustable users, CCPP(Combined Cycle Power Plant), blending boilers and gas tanks to maximize overall efficiency; diversification of the buffer unit to ensure security and stability of gas system and qualified enterprises should establish CCPP.


Sign in / Sign up

Export Citation Format

Share Document