scholarly journals Influence of femoral morphology and canal fill ratio on early radiological and clinical outcomes of uncemented total hip arthroplasty using a fully coated stem

2020 ◽  
Vol 9 (4) ◽  
pp. 182-191
Author(s):  
Adrien D’Ambrosio ◽  
Lisa Peduzzi ◽  
Olivier Roche ◽  
Hugo Bothorel ◽  
Mo Saffarini ◽  
...  

Aims The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components. Methods We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the lesser trochanter (LT) using immediate postoperative radiographs: P1, 2 cm above LT; P2, at LT; P3, 2 cm below LT; and D1, 7 cm below LT. At two years, radiological femoral component osseointegration was evaluated using the Engh score, and hip function using the Postel Merle d’Aubigné (PMA) and Oxford Hip Score (OHS). Results CFR was moderately correlated with CCR at P1 (r = 0.44; p < 0.001), P2 (r = 0.53; p < 0.001), and CFI at P1 (r = − 0.56; p < 0.001). Absence of spot welds (n = 3, 2%) was associated with lower CCR (p = 0.049), greater CFI (p = 0.017), and lower CFR at P3 (p = 0.015). Migration (n = 9, 7%) was associated with lower CFR at P2 (p = 0.028) and P3 (p = 0.007). Varus malalignment (n = 7, 5%), predominantly in Dorr A femurs (p = 0.028), was associated with lower CFR at all levels (p < 0.05). Absence of spot welds was associated with lower PMA gait (p = 0.012) and migration with worse OHS (p = 0.032). Conclusion This study revealed that femurs with insufficient proximal filling tend to have less favourable radiological outcomes following uncemented THA using a fully HA-coated double-tapered femoral component. Cite this article: Bone Joint Res. 2020;9(4):182–191.

2021 ◽  
Vol 2 (1) ◽  
pp. 33-39
Author(s):  
Jeffrey R. McLaughlin ◽  
Kyla R. Lee ◽  
Mary Ann Johnson

Aims We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39.


2015 ◽  
Vol 26 (1) ◽  
pp. 62-66 ◽  
Author(s):  
John B. Meding ◽  
Merrill A. Ritter ◽  
Kenneth E. Davis ◽  
Maggie Hillery

2013 ◽  
Vol 7 (1) ◽  
pp. 272-274 ◽  
Author(s):  
Wenzel Waldstein ◽  
Friedrich Boettner

Press-fit component fixation is one of the primary goals in uncemented total hip arthroplasty. When aiming at proximal load transfer, the stem size has to be selected with regard to the shape of the proximal femoral canal. This can be challenging in patients with ‘champagne flute’ femurs with a relatively narrow diaphysis, especially when a long stem femoral component is used. The present case report describes a complication during femoral broaching for a primary uncemented femoral component. Because of the narrow diaphysis, the distal portion of the broach got caught in the narrow canal and it became impossible to remove the broach with conventional techniques. Via a second distal incision, the femur was split from the distal tip of the broach to approximately 5 cm distal of the femoral neck cut along the posterior aspects of the femur. This loosened the broach enough to allow for an uncomplicated removal. The longitudinal split was secured with cables before a similar size primary implant was press fitted into the femoral canal.


2020 ◽  
Vol 4 (04) ◽  
pp. 155-157
Author(s):  
Michael Newman ◽  
David Hartwright

AbstractThe aim of this study was to assess a large, single-surgeon dataset of uncemented total hip arthroplasties that had been templated using software. This assessment compared preoperative templated predictions with what was implanted with regard to (1) femoral prosthesis size and (2) acetabular cup size. The operation notes for two types of uncemented total hip arthroplasty performed by a single surgeon between January 9, 2008, and March 21, 2019, were assessed. The data were refined so that only those that were fully templated on a correctly calibrated pelvic radiograph were included. This provided a total of 153 cases. The predicted software template was compared with actual implanted component sizes. With regard to the femoral stems, the templating software was exactly correct in 45.75% of cases and was accurate to within one size in 87.59% of cases. With regard to the acetabular component, the templating software was exactly correct in 52.94% of cases and was accurate to within one size (2 mm) in 86.94% of cases. Templating software offers an accurate prediction of the size of uncemented femoral and acetabular components. In addition, the benefits of templating include cognitive rehearsal, insight into potentially challenging aspects of surgery, and highlighting intraoperative issues where there is a large intraoperative deviation from what is templated. This study demonstrates the congruence and reproducibility of templating software when compared with other smaller studies performed in the literature.