Ammonia Emission Factors Modelling for a Naturally Ventilated Dairy Housing System with Cubicles, Solid Floors and an Outdoor Exercise Area

2012 ◽  
Author(s):  
Sabine Schrade ◽  
Lorenz Gygax ◽  
Margret Keck
2012 ◽  
Vol 52 (12) ◽  
pp. 1089 ◽  
Author(s):  
Annamaria Costa ◽  
Sara Ferrari ◽  
Marcella Guarino

The aim of the present study was to measure the concentration of ammonia and particulate matter (PM) that passes through a size‐selective inlet with a 50% cut‐off at 10-μm aerodynamic-equivalent diameter (PM10) and emissions into atmosphere in the following three types of laying-hen houses: traditional battery cages with aerated open-manure storage (BSP) and two best available technique (BAT) housing types, namely, an aviary-system housing (ASH) and a vertical tiered cage with manure belts and forced-air drying (VTC). Measurements were taken continuously for a period of 1 year in each house. Ammonia concentration was measured continuously in each house using an infrared photoacoustic detector with a 15-min sampling interval. PM10 was measured continuously using a scatter light photometer, corrected by the traditional gravimetric-technique concentration to lower the measurement error. The same instrument was also used to collect PM10 through a traditional gravimetric technique. This procedure was performed to adjust the particulate matter-specific gravity of PM that is typical and specific for every animal house. PM10 and ammonia measurements were carried out together with measurements of inside and outside temperature, inside and outside relative humidity and ventilation rate. For the high PM10 concentrations measured in the ASH house during a preliminary survey, concentrations of total suspended particles (TSP) and fine PM (particles <2.5 microns) were also measured to evaluate the dustiness in the building during the working hours. The ammonia concentration was 5.37 mg/m3 in the traditional BSP house (the reference for cage-housing system), 4.95 mg/m3 in the VTC and 3.85 mg/m3 in the ASH. The ammonia-emission factors were 15.445 mg/h.hen place (0.135 kg/year.hen place) for BSP, 8.258 mg/h.hen place (0.072 kg/year.hen place) for VTC, and 23.704 mg/h.hen place (0.208 kg/year.hen place) for ASH. Ammonia emission-reduction efficiency of VTC v. the BSP was 53%, according to thresholds assessed by Integrated Prevention Pollution Control. The ammonia-reduction efficiency of ASH v. that of the standard Reference Housing system for non-cage housing was 68%. Average yearly PM10 concentration was remarkably higher in the ASH, with 0.215 mg/m3 v. 0.108 mg/m3 for the VTC and 0.094 mg/m3 for BSP. In the ASH, the concentration of total suspended particles (TSP) was 0.444 mg/m3 and that of PM2.5 was 0.032 mg/m3. In this facility, a great variation of PM10 concentration occurred in the morning hours. Recorded values for the PM10 emission were 0.433 mg/h.hen for BSP and 0.081 mg/h.hen for VTC, while the ASH showed the highest PM10 emission (1.230 mg/h.hen), with clear peaks occurring in the morning hours during daily farming operations.


2021 ◽  
Vol 13 (4) ◽  
pp. 2197
Author(s):  
Seongmin Kang ◽  
Joonyoung Roh ◽  
Eui-chan Jeon

NH3 is one of the major substances contributing to the secondary generation of PM2.5; therefore, management is required. In Korea, the management of NH3 is insufficient, and the emission factor used by EPA is the same as the one used when calculating emissions. In particular, waste incineration facilities do not currently calculate NH3 emissions. In the case of combustion facilities, the main ammonia emission source is the De-NOx facility, and, in the case of a power plant with a De-NOx facility, NH3 emission is calculated. Therefore, in the case of a Municipal Solid Waste (MSW) incinerator with the same facility installed, it is necessary to calculate NH3 emissions. In this study, the necessity of developing NH3 emission factors for an MSW incinerator and calculating emission was analyzed. In addition, elements to be considered when developing emission factors were analyzed. The study found that the NH3 emission factors for each MSW incinerator technology were calculated as Stoker 0.010 NH3 kg/ton and Fluidized Beds 0.004 NH3 kg/ton, which was greater than the NH3 emission factor 0.003 NH3 kg/ton for the MSW incinerator presented in EMEP/EEA (2016). As a result, it was able to identify the need for the development of NH3 emission factors in MSW incinerators in Korea. In addition, the statistical analysis of the difference between the incineration technology of MSW and the NH3 emission factor by the De-NOx facility showed a difference in terms of both incineration technology and De-NOx facilities, indicating that they should be considered together when developing the emission factor. In addition to MSW, it is believed that it will be necessary to review the development of emission factors for waste at workplaces and incineration facilities of sewage sludge.


Author(s):  
Luciano B. Mendes ◽  
Ilda F. F. Tinoco ◽  
Nico W. M. Ogink ◽  
Keller S. O. Rocha ◽  
Jairo A. Osorio S. ◽  
...  

This study was conducted with the aim of monitoring NH3 emissions from a mechanically and a naturally ventilated broiler house (MVB and NVB, respectively) and calculate their ammonia emission factors (fNH3). Bird stocking density was 13.5 and 11.1 birds m-2 for the MVB and NVB, respectively. The marketing age was 43 days and bedding consisted of dried coffee husks in its first time of use. Ventilation rates were calculated with the metabolic carbon dioxide mass balance method. Values of fNH3 were 0.32 ± 0.10 and 0.27 ± 0.07 g bird-1 d-1 for the MVB and NVB, respectively, and are in agreement to what was presented in other studies performed under similar conditions. The fNH3 estimated on yearly basis was 58 g bird-place-1 year-1. It was concluded that the different types of ventilation system between the studied broiler barns did not significantly affect emissions in the modeling process. The results obtained help providing reliable methodology for the determination of a solid database on NH3 emission factors for tropical conditions that can be used for future inventories, when performed in a sufficient number of barns that is representative for the Brazilian scenario.


2015 ◽  
Vol 140 ◽  
pp. 79-90 ◽  
Author(s):  
Tim Ulens ◽  
Matthijs R.J. Daelman ◽  
Julio Mosquera ◽  
Sam Millet ◽  
Mark C.M. van Loosdrecht ◽  
...  

1998 ◽  
Vol 32 (3) ◽  
pp. 315-316 ◽  
Author(s):  
K.W Van Der Hoek

2004 ◽  
Vol 50 (4) ◽  
pp. 335-340 ◽  
Author(s):  
G. Mol ◽  
N.W.M. Ogink

Odour nuisance from agricultural activities is increasing in densely populated countries like the Netherlands. To develop adequate regulations, a large-scale, government-financed monitoring programme was started in the mid-1990s to establish odour emission levels for both conventional and low ammonia emission housing systems for cattle, pigs and poultry. The results indicate that high- and low-odour emission housing are difficult to distinguish because of the large variation within housing systems. Measurements on different farm locations within the same housing system show both a large variation between locations and within one location (in time). The latter, however, is significantly smaller, which suggests that farm management is an important determinant in odour emission that interferes with the effects of housing systems. The current research was aimed at determining the effect of two common ammonia-reducing pig-housing systems on odour emissions compared to conventional housing systems under similar management conditions. The respective reduction principles of these systems are reducing the emitting surface of the manure pit and cooling of manure in the manure pit (both pits beneath slatted floor). Five farms that combined conventional housing with one low-ammonia system (three reduced emitting surface and two manure cooling) were selected for a direct, pair-wise comparison of (olfactometric) odour emission measurements. The results show a highly significant effect (p &lt; 0.01) for two of the three reduced emitting surface systems and for one of the two manure cooling system. The average odour reduction percentages of these systems are 35% (from 24.9 to 16.0 OUE/s per animal) and 23% (from 30.1 to 24.0 OUE/s per animal) respectively. Although odour emission reduction through the type of housing system is possible, management factors interact with the system and thereby determine whether the system reduces odour emission or not.