scholarly journals Terahertz artificial material based on integrated metal-rod-array for phase sensitive fluid detection

2017 ◽  
Vol 25 (8) ◽  
pp. 8571 ◽  
Author(s):  
Borwen You ◽  
Ching-Yu Chen ◽  
Chin-Ping Yu ◽  
Tze-An Liu ◽  
Toshiaki Hattori ◽  
...  
Author(s):  
D.J. Eaglesham

Convergent Beam Electron Diffraction is now almost routinely used in the determination of the point- and space-groups of crystalline samples. In addition to its small-probe capability, CBED is also postulated to be more sensitive than X-ray diffraction in determining crystal symmetries. Multiple diffraction is phase-sensitive, so that the distinction between centro- and non-centro-symmetric space groups should be trivial in CBED: in addition, the stronger scattering of electrons may give a general increase in sensitivity to small atomic displacements. However, the sensitivity of CBED symmetry to the crystal point group has rarely been quantified, and CBED is also subject to symmetry-breaking due to local strains and inhomogeneities. The purpose of this paper is to classify the various types of symmetry-breaking, present calculations of the sensitivity, and illustrate symmetry-breaking by surface strains.CBED symmetry determinations usually proceed by determining the diffraction group along various zone axes, and hence finding the point group. The diffraction group can be found using either the intensity distribution in the discs


2020 ◽  
Vol 13 (4) ◽  
pp. 184-190
Author(s):  
Muhammad Irfan ◽  
Abdul Rasheed Qureshi ◽  
Zeeshan Ashraf ◽  
Muhammad Amjad Ramzan ◽  
Tehmina Naeem ◽  
...  

ABSTRACT Background: Conventionally Pleural effusions are suspected by history of pleuritis, evaluated by physical signs and multiple view radiography. Trans-thoracic pleural aspiration is done and aspirated pleural fluid is considered the gold-standard for pleural effusion. Chest sonography has the advantage of having high diagnostic efficacy over radiography for the detection of pleural effusion. Furthermore, ultrasonography is free from radiation hazards, inexpensive, readily available  and feasible for use in ICU, pregnant and pediatric patients. This study aims to explore the diagnostic accuracy of trans-thoracic ultrasonography for pleural fluid detection, which is free of such disadvantages. The objective is to determine the diagnostic efficacy of trans-thoracic ultrasound for detecting pleural effusion and also to assess its suitability for being a non-invasive gold-standard.   Subject and Methods: This retrospective study of 4597 cases was conducted at pulmonology  OPD-Gulab Devi Teaching Hospital, Lahore from November 2016 to July 2018. Adult patients with clinical features suggesting pleural effusions were included while those where no suspicion of pleural effusion, patients < 14 years and pregnant ladies were excluded. Patients were subjected to chest x-ray PA and Lateral views and chest ultrasonography was done by a senior qualified radiologist in OPD. Ultrasound-guided pleural aspiration was done in OPD & fluid was sent for analysis. At least 10ml aspirated fluid was considered as diagnostic for pleural effusion. Patient files containing history, physical examination, x-ray reports, ultrasound reports, pleural aspiration notes and informed consent were retrieved, reviewed and findings were recorded in the preformed proforma. Results were tabulated and conclusion was drawn by statistical analysis. Results: Out of 4597 cases, 4498 pleural effusion were manifested on CXR and only 2547(56.62%) pleural effusions were proved by ultrasound while 2050 (45.57%) cases were reported as no Pleural effusion. Chest sonography demonstrated sensitivity, specificity, PPV, NPV and diagnostic accuracy 100 % each. Conclusions: Trans-thoracic ultrasonography revealed an excellent efficacy that is why it can be considered as non-invasive gold standard for the detection of pleural effusion.


1997 ◽  
Vol 62 (11) ◽  
pp. 1747-1753 ◽  
Author(s):  
Radek Marek

Determination of 15N chemical shifts and heteronuclear coupling constants of substituted 2,2-dimethylpenta-3,4-dienal hydrazones is presented. The chemical shifts were determined by gradient-enhanced inverse-detected NMR techniques and 1H-15N coupling constants were extracted from phase-sensitive gradient-enhanced single-quantum multiple bond correlation experiments. Stereospecific behaviour of the coupling constants 2J(1H,15N) and 1J(1H,13C) has been used to determine the configuration on a C=N double bond. The above-mentioned compounds exist predominantly as E isomers in deuteriochloroform.


Sign in / Sign up

Export Citation Format

Share Document