scholarly journals COMPARISON OF HAEMODYNAMIC CHANGES IN RESPONSE TO ENDOTRACHEAL INTUBATION AND LARYNGEAL MASK AIRWAY IN CONTROLLED HYPERTENSIVE PATIENTS- A RANDOMISED STUDY

2017 ◽  
Vol 6 (17) ◽  
pp. 1313-1316
Author(s):  
Vanilla Chopra ◽  
Vikas Gupta ◽  
Abdul Qayoom Lone ◽  
Imtiaz Naqash A
2020 ◽  
Vol 3 (4) ◽  
pp. 422-429
Author(s):  
SI Nuhu ◽  
GA Ajogwu ◽  
HY Embu ◽  
FD Atteh ◽  
DU Orshio ◽  
...  

To determine the haemodynamic changes at induction during laryngeal mask airway (LMA) insertion comparing propofol versus lignocaine-thiopentone admixture. In this comparative randomised study, patients of American Society of Anesthesiologists’ (ASA) class I and II with age range of 18-60 years scheduled for short elective surgeries were randomly assigned into two equal groups. Patients were premedicated with fentanyl 1ug.kg-1. Anaesthesia was induced with either 2.5mg.kg-1 propofol or a sequence of 2mg.kg-1 lignocaine and 5mg.kg-1 thiopental given by a trained assistance. Anaesthesia was maintained with 2% isoflurane and 100% oxygen. Haemodynamic variables [Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP) and Heart Rate (HR)] were measured non-invasively in three periods; before drug administration, immediately after drug administration prior to insertion of LMA and finally after LMA insertion.In group A, the baseline heart rate (92.3±11) was compared to the post-induction heart rate (100.7±09) with p=0.765 and post-insertion heart rate (98.0±13) with p=0.767. Although, there was a rise in the heart rate from the baseline after induction and insertion of LMA, this was not statistically significant. Also, baseline SBP (120.7±09) was compared to the post-induction SBP (102.5±07) with p=0.001 and post-insertion SBP (102.59±07) with p=0.001. This was statistically significant. The baseline DBP (77.9±08) was compared to the post-induction DBP (67.0±12) with p=0.004 and post-insertion DBP (62.5±09) with p=0.001.This was statistically significant. The baseline MAP (92.6±01) was compared to the post-induction MAP (79.7±01) with p=0.008 and post-insertion MAP (76.2±07) with p=0.001. This was also statistically significant. In group B, the baseline heart rate (93.2±12) was compared to post-induction heart rate (99.2±11) with p=0.520 and post-insertion heart rate (94.8±12) with p=0.989. This was not statistically significant. The baseline SBP (120.7±13) was compared to the post-induction SBP (115.9±12) with p=0.139 and post-insertion SBP (117.5±13) with p=0.318. This was not statistically significant. The baseline DBP (80.6±14) was compared to the post-induction DBP (75.2±11) with p=0.636 and post-insertion DBP (76.6±13) with p=0.712. This was also not statistically significant. The baseline MAP (94.3±01) was compared to the post-induction MAP (87.5±01) with p=0.779 and post-insertion MAP (88.3±01) with p=0.882. This was not statistically significant. We concluded that propofol and lignocaine-thiopentone admixture exhibited similar haemodynamic profile in our study and therefore recommend that both drugs can be used for patients.


2019 ◽  
Author(s):  
Mehdi Sanatkar ◽  
Mehrdad Goudarzi ◽  
Alireza Ebrahim Soltani

 We compared hemodynamic responses following laryngeal mask airway insertion versus tracheal intubation in hypertensive patients who were scheduled for elective ophthalmic surgery under general anesthesia. We studied 48 controlled hypertensive patients that were randomly divided into two groups (n=24) for insertion of laryngeal mask airway (LMA) and endotracheal intubation (EI). The mean arterial blood pressure (MAP), heart rate, rate pressure product (RPP), and ST-segment changes were recorded preoperatively, immediately preintubation and 1, 3, and 5 minutes after LMA insertion or tracheal intubation in all patients and compared between two groups. There was a reduction in MAP after induction and immediately preintubation in all of patients of both groups (P<0.05). The MAP, heart rate and RPP increased immediately after both LMA insertion and tracheal intubation (P<0.05). The elevation of MAP and RPP were maintained for longer time in intubation group versus LMA group (P<0.05). There was no difference between the groups with respect to ST-segment variation. The incidence of airway injury was similar between two groups. The laryngeal mask airway insertion may be preferable to endotracheal intubation in hypertensive patients where attenuation of hemodynamic stress response is desired. © 2019 Tehran University of Medical Sciences. All rights reserved. Acta Med Iran 2019;57(5):289-294.


2002 ◽  
Vol 56 (1) ◽  
pp. 122-128 ◽  
Author(s):  
Irene P. Osborn ◽  
Jonathan Cohen ◽  
Robert J. Soper ◽  
Leslie A. Roth

Sign in / Sign up

Export Citation Format

Share Document