scholarly journals PROSPECTIVE ANALYSIS OF FUNCTIONAL OUTCOME OF CLAVICLE FRACTURES TREATED BY PLATE OSTEOSYNTHESIS

2018 ◽  
Vol 7 (15) ◽  
pp. 1825-1828
Author(s):  
Karthi M. N ◽  
Premkumar T. C ◽  
Kailash K
2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
Enzhe Zhao ◽  
Rui Zhang ◽  
Dou Wu ◽  
Yao Guo ◽  
Qiang Liu

Objective. The aim of this study was to compare the functional outcome and complications in midshaft clavicle fractures receiving minimally invasive plate osteosynthesis and conventional open plating. Methods. Relevant studies were searched in the databases of Medline, EMBASE, Cochrane Library, Ovid, and Web of Science from inception to March 1, 2019. Pooled data were analyzed with Cochrane Collaboration’s Review Manager 5.3. Results. A total of 7 studies were included, of which 2 were randomized controlled trials, 3 were retrospective cohort studies, and 2 were prospective cohort studies including 316 patients. No statistical differences in functional outcome (weighted mean difference [WMD] = 0.99, P=0.12), operation time (WMD = −10.44, P=0.07) and time to bone union (WMD = −0.23, P=0.70) were observed between the two groups. However, minimally invasive plate osteosynthesis reduced rates of skin numbness (odds ratio (OR) = 0.25, 95% CI : 0.13 to 0.48; P<0.0001) and complications (OR = 0.33, 95% CI : 0.16 to 0.71; P=0.005) compared with conventional open plating. Conclusion. This systematic review and meta-analysis found no differences in terms of functional outcomes, operation time, and fracture healing time between minimally invasive plate osteosynthesis and conventional open plating. However, minimally invasive plate osteosynthesis had apparent advantages in rates of skin numbness and complications.


2020 ◽  
pp. 221049172097518
Author(s):  
Vineet Thomas Abraham ◽  
Chandrasekaran Marimuthu

Purpose: Fixation of displaced midshaft clavicle is well known to decrease nonunion, malunion and shoulder disability as compared to nonoperative treatment. This study was done to compare the clinical and functional outcome of group 1 clavicle fractures treated with anatomic locking plates (ALP) versus Titanium elastic nail (TEN). Methods: We studied patients presenting with displaced midshaft clavicle fractures treated with ALP or TEN. The study period was from Jan 2013 to Dec 2016. Patients were reviewed and at each visit clinical and radiological progress of union was noted, complications if any were noted, functional assessment was done using the quick Dash score and Constant Murley score. Results: A total of 116 patients met our inclusion criteria. 62 patients were treated with TEN and 54 with ALP. Bony union was achieved at an average of 11.8 weeks in the TENS group and 12.8 weeks in the ALP group post operatively and this was found to be significant. The mean postoperative Constant Murley score in the ALP and the TEN groups were 92.8 (range 80–97), and 93.7 (82–97) respectively. The mean postoperative quick dash score in the ALP and TEN groups were 2.48(range from 0 to 6.8) and 2.1 (range 0–9.1) respectively. Conclusion: Both Anatomical locking plate and TEN are good options for the treatment of non-comminuted mid clavicular fractures as they have a similar functional outcome. TEN nail insertion has the advantage of being minimally invasive, having a faster union time and may be recommended in midshaft clavicle fractures without comminution.


Author(s):  
Vivek Phanswal

Background: Clavicle Fractures is one of the common fractures of upper limb accounting for approximately 40 % of all shoulder fractures. Till recently all clavicle fracture were treated conservatively, but now interest in surgical management is rising. This study was carried out to see if Surgical management outweighs the conservative treatment of Fractures Of Clavicle. Methods: A total of 40 cases satisfying inclusion and exclusion criteria were included in the study. Alternate patients were allocated to operative and conservation groups. In total 20 patients were operated operatively and 20 patients were treated conservatively. Outcome was analysed in terms of radiological union and functional outcome of the patient. Constant and Murley score was used as a score to evaluate final outcome. Results: In this study, the 20 patients who were operated upon had an average union time of 7.8 weeks; 1 patient had delayed fracture union by 12 wks. 20 patients in conservative group had normal union of fractures with 1 patient going into non-union. Average union time in the conservative group was 9.4 weeks, which was more than the 7.8 weeks seen in the group treated operatively. Mal-union was present in 7 of the 20 patients treated conservatively, and 5 of these 7 had a visible deformity. Out of these patients with mal-union 1 had poor functional outcome, 3 had good to excellent outcome and 3 had satisfactory functional outcome. 4 of these had restricted movements terminally and 2 had pain on movement. Conclusions: From our study based on patients of clavicle fractures, it can be concluded that the operative group had significantly higher excellent outcomes as compared to the conservatively- managed group, based on the Constant and Murley score. Keywords: Clavicle Fractures, Constant and Murley Score, Operative Clavicle Fracture Management, Clavicle Fracture Functional Outcome.


2016 ◽  
Vol 4 (4) ◽  
pp. 647-649 ◽  
Author(s):  
Tabet A. Al-Sadek ◽  
Desislav Niklev ◽  
Ahmed Al-Sadek

BACKGROUND: Fractures of the clavicle are one of the most common fractures in modern orthopaedics and traumatology practice. Knowing the mechanism of trauma, and it's pathophysiological elements, it's clear distinction and it's individual features are essential to the development of more new and effective methods for their treatment, and the minimising of postoperative complications.AIM: The aim of this paper was to present the results of our patients treated with minimally invasive plate osteosynthesis (MIPO).MATERIAL AND METHODS: Between January 2011 and March 2013, 12 patients were treated with MIPO technique. The mean age was 47.5 years (range, 16-79 years). Outcomes and complications of clinical treatment were reviewed.RESULTS: All fractures healed within a mean period of 4.9 months (range, 2-10 months). Regarding complications, there was no occurrence of implant failure or deep infection. There were no nonunions, but one 79-year-old man had a delayed union. Almost of all the cases didn’t need bending of the plate. Seven plates were removed by their hopes. And there weren’t any cases that required new incisions.CONCLUSIONS: A pre-contoured plate anatomically configured to fit the clavicle was easier to apply. MIPO technique for midshaft clavicle fractures may be a good option.