Temperature-insensitive intensity-modulation liquid refractive index sensor based on fiber-optic Michelson probe structure

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Chen Zheng ◽  
Wenlin Feng ◽  
Xiaozhan Yang ◽  
Guojia Huang ◽  
Lian Wang ◽  
...  

Abstract A novel liquid refractive index sensor based on the connected single-mode fiber (SMF), no-core fiber (NCF), four-core fiber (FCF), and silver mirror (SM) to form an SMF–NCF–FCF–SM Michelson probe structure is proposed and fabricated. The change of light field in the probe structure has been simulated by the light-beam propagation method. The theoretical results show that light is excited in the NCF and couples into the cores and cladding of FCF at the junction of NCF and FCF. The interference fringes are generated between the cladding modes and core modes of FCF. The sensitivities of the probe in NaCl, sucrose, and glycerol are 171.75 dB/RIU, 121.41 dB/RIU, and 207.50 dB/RIU, respectively. The temperature sensitivity is 0.05 nm/°C, and the intensity change of temperature (≤0.046 dB/°C) is very small and has little effect on the liquid refractive index. Thus, the cross-sensitivity of temperature for the liquid refractive index can be removed. The proposed probe structure has the advantages of easy fabrication, good stability, and linear response, having potential application in the liquid refractive index monitoring environments.

Sensors ◽  
2018 ◽  
Vol 18 (7) ◽  
pp. 2396 ◽  
Author(s):  
Jing Kang ◽  
Jiuru Yang ◽  
Xudong Zhang ◽  
Chunyu Liu ◽  
Lu Wang

A novel intensity demodulated refractive index (RI) sensor is theoretically and experimentally demonstrated based on the front-tapered single-mode-multimode-single-mode (FT-SMS) fiber structure. The front taper is fabricated in a section of multimode fiber by flame-heated drawing technique. The intensity feature in the taper area is analyzed through the beam propagation method and the comprehensive tests are then conducted in terms of RI and temperature. The experimental results show that, in FT-SMS, the relative sensitivity is −342.815 dB/RIU in the range of 1.33~1.37. The corresponding resolution reaches 2.92 × 10−5 RIU, which is more than four times higher than that in wavelength demodulation. The temperature sensitivity is 0.307 dB/°C and the measurement error from cross-sensitivity is less than 2 × 10−4. In addition, fabricated RI sensor presents high stability in terms of wavelength (±0.045 nm) and intensity (±0.386 dB) within 2 h of continuous operation.


Sensors ◽  
2012 ◽  
Vol 12 (4) ◽  
pp. 4697-4705 ◽  
Author(s):  
Jie Shi ◽  
Shilin Xiao ◽  
Lilin Yi ◽  
Meihua Bi

2013 ◽  
Vol 40 (9) ◽  
pp. 0905001
Author(s):  
陈耀飞 Chen Yaofei ◽  
韩群 Han Qun ◽  
何洋 He Yang ◽  
刘铁根 Liu Tiegen ◽  
洪成青 Hong Chengqing

2019 ◽  
Vol 48 ◽  
pp. 297-302 ◽  
Author(s):  
Mizhen Zhang ◽  
Guixian Zhu ◽  
Lidan Lu ◽  
Xiaoping Lou ◽  
Lianqing Zhu

Sign in / Sign up

Export Citation Format

Share Document