scholarly journals Determination of Edoxaban in Bulk and in Tablet Dosage Form by Stability Indicating High-Performance Liquid Chromatography

2016 ◽  
Vol 22 (1) ◽  
pp. 35-41 ◽  
Author(s):  
Pasam Reddy ◽  
V. Shanmukha Jagarlapudi ◽  
Chandra Sekaran
Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Ramreddy Godela ◽  
Sherisha Bhavani

Objective: The most important objective of the present research work is to develop simple, specific, rapid, accurate, and sensitive reverse-phase high-performance liquid chromatography method and validated for the qualitative and quantitative determination of valsartan in its active pharmaceutical ingredient and tablet dosage form according to ICH guidelines.Proposed Method: An isocratic separation was done using Phenomenex C18 column possess 75×4.6 mm, 2.6 μ,100 A0 dimensions with mobile phase composition of water:acetonitrile (30:70% v/v) by maintaining 1 ml/minute flow rate and response detected at a wavelength of 247 nm.Results: The retention time of valsartan was found to be 2.71 minutes, limit of detection and limit of quantification were observed at 1.24 μg/ml and 3.6 μg/ml concentration, respectively, and a calibration curve was linear in the concentration range of 5-50 μg/ml with coefficient of correlation 0.99. The percentage recovery (accuracy) was in the range of 98.9-102%, and the % relative standard deviation was observed to be <2%.Conclusion: The proposed method was validated for accuracy, precision, sensitivity, linearity, and robustness and successfully employed for the quantitative determination of valsartan in tablet dosage form in quality control department of pharmaceutical industry.


Sign in / Sign up

Export Citation Format

Share Document