Performance of active power filter in transient under non-linear loading

2016 ◽  
Vol 1 (5) ◽  
pp. 247-251
Author(s):  
Julian WOSIK
2014 ◽  
Vol 3 (2) ◽  
pp. 59-75
Author(s):  
Saifullah Khalid ◽  
Neeraj Kumar ◽  
V.M. Mishra

A novel hybrid series active power filter to eliminate harmonics and compensate reactive power is presented and analyzed. The proposed active compensation technique is based in a hybrid series active filter using adaptive Tabu search (ATS) algorithm in the conventional Sinusoidal Fryze voltage (SFV) control technique. Optimization of the conventional Sinusoidal Fryze voltage control technique has been done using adaptive tabu search algorithm. This paper discusses about the comparative performances of conventional Sinusoidal Fryze voltage control strategy and ATS-optimized controllers. ATS algorithm has been used to obtain the optimum value of Kp and Ki. Analysis of the hybrid series active power filter system under non linear load condition and its impact on the performance of the controllers is evaluated. Effectiveness of the hybrid series active power filter to provide harmonic damping is demonstrated by MATLAB/Simulink results. Total harmonic distortion (THD) demonstrates the practical viability of the controller for hybrid series active power filter to provide harmonic isolation of non-linear loads and to comply with IEEE 519 recommended harmonic standards.


Author(s):  
P. Thirumoorthi ◽  
Raheni T D

Power system harmonics are a menace to electric power system with disastrous consequence. Due to the presence of non linear load, power quality of the system gets affected.  To overcome this, shunt active power filter have been used near harmonic producing loads or at the point of common coupling to block current harmonics. The shunt active power filter is designed to minimize harmonics in source current and reactive power in the non linear power supplies which are creating harmonics. In this paper, Instantaneous power of p-q theory is employed to generate the reference currents and PI controller is used to control the dc link voltage. In addition to this, Artificial Intelligence (AI) technique is used to minimize the harmonics produced by nonlinear load. The main objective of this paper is to analyze and compare THD of the source current with PI controller and by artificial neural network based back propagation algorithm. The proposed system is designed with MATLAB/SIMULINK environment.


2019 ◽  
Vol 11 (12-SPECIAL ISSUE) ◽  
pp. 1193-1204 ◽  
Author(s):  
G. Boopathy ◽  
Dr.M. Siva Ramkumar ◽  
Dr.A. Amudha ◽  
Dr. Viyathukattuva ◽  
Dr.G. Emayavaramban ◽  
...  

This paper presents the simulation-based study and results of a three-phase shunt active power filter (SAPF) for power quality improvement. The power quality of the power systems is degraded because of the presence of non-linear loads at the consumer end. The SAPF can reduce the impact of harmonics caused by the non-linear loads. The analyzed SAPF system is modeled and simulated using MATLAB-Simulink workspace. The ultimate goal of this study is to improve the total harmonic distortion of the system as per the standards defined by IEEE-519.


Author(s):  
Saifullah Khalid

A novel hybrid series active power filter to eliminate harmonics and compensate reactive power is presented and analyzed. The proposed active compensation technique is based on a hybrid series active filter using ATS algorithm in the conventional Sinusoidal Fryze voltage (SFV) control technique. This chapter discusses the comparative performances of conventional Sinusoidal Fryze voltage control strategy and ATS-optimized controllers. ATS algorithm has been used to obtain the optimum value of Kp and Ki. Analysis of the hybrid series active power filter system under non-linear load condition and its impact on the performance of the controllers is evaluated. MATLAB/Simulink results and Total harmonic distortion (THD) shows the practical viability of the controller for hybrid series active power filter to provide harmonic isolation of non-linear loads and to comply with IEEE 519 recommended harmonic standards. The ATS-optimized controller has been attempted for shunt active power filter too, and its performance has also been discussed in brief.