Transcatheter Aortic Valve Implantation after Previous Mechanical Mitral Valve Replacement: Expanding Indications?

2011 ◽  
Vol 14 (3) ◽  
pp. 166 ◽  
Author(s):  
Carsten J. Beller ◽  
Raffi Bekeredjian ◽  
Ulrike Krumsdorf ◽  
R�diger Leipold ◽  
Hugo A. Katus ◽  
...  

<p><b>Background:</b> Cardiac operation for severe aortic stenosis after previous mitral valve replacement is a surgical challenge in older patients with multiple morbidities. Transcatheter aortic valve implantation (TAVI) after previous mechanical mitral valve replacement has been considered a high-risk procedure, owing to possible interference with the mitral valve prosthesis.</p><p><b>Methods:</b> Since August 2008, 5 female high-risk patients with severe aortic stenosis and previous mitral valve replacement (mean � SD age, 80 � 5.1 years; logistic EuroSCORE, 39.3% � 20.5%) underwent TAVI with a pericardial xenograft valve that was fixed with a stainless steel, balloon-expandable stent (Edwards Lifesciences SAPIEN). We used a transapical approach in 4 patients and a transfemoral approach in 1 patient. Transesophageal echocardiography and multidetector computed tomography were used for preoperative planning and assessment of operation feasibility. The mean distance between the aortic annulus and the mitral valve prosthesis was 10 � 1 mm (range, 9-11 mm).</p><p><b>Results:</b> TAVI was performed successfully in all 5 patients. There was no direct or functional interference with the mechanical mitral valve prostheses. Echocardiography revealed good valve function with no more than mild paravalvular incompetence early in the postoperative period and during routine follow-up. There were no neurologic events. After an initially uneventful course with good aortic valve function at the most recent echocardiography evaluation, however, 2 of the patients died from fulminant pneumonia on postoperative days 4 and 48.</p><p><b>Conclusion:</b> TAVI is technically feasible in high-risk patients after previous mechanical mitral valve replacement; however, careful patient selection is mandatory with respect to preoperative clinical status and anatomic dimensions regarding the distance between aortic annulus and mitral valve prosthesis.</p>

Author(s):  
Ahmet Korkmaz ◽  
Havva Tuğba Gürsoy ◽  
Mehmet İleri ◽  
Özgül Uçar Elalmış ◽  
Ümit Güray

Transcatheter aortic valve implantation (TAVI) has shown favorable outcomes in patients with severe symptomatic aortic valve stenosis who are at high surgical risk or who are unsuitable candidates for open-heart surgery. However, concerns exist over treating patients who have undergone previous mitral valve surgery due to the potential interference between the mitral prosthetic valve or ring and the TAVI device. In this case report, we present a case in which a patient with symptomatic severe aortic stenosis and previous mechanical mitral valve replacement was successfully treated with TAVI using a Portico valve, which is under-researched.   J Teh Univ Heart Ctr 2019;14(2):85-89   This paper should be cited as: Korkmaz A, Gürsoy HT, İleri M, Uçar Elalmış Ö, Güray Ü. Transcatheter Self-expandable Aortic Valve (Portico) Implantation in a Patient with Previous Mitral Valve Replacement: A Case Report. J Teh Univ Heart Ctr 2019;14(2):85-89.


Sign in / Sign up

Export Citation Format

Share Document